Fluke 115 True-RMS Digital Multimeter

Sku: 1699150971-82
Allschoolabs genuine seal

Estimated Delivery Date: International: 2-3 days (by DHL Express)

See Recent Deliveries to your City Here . Use Live Chat to ask Questions

Fluke 115 True-RMS Digital Multimeter

Sku: 1699150971-82

1,000.00

Quantity:

Available in stock

Express delivery on this item

380000+ Products Online

100% Money Back

Description

Buy Fluke 115 True-RMS Digital Multimeter from Safety Nigeria, with fast delivery.
Key features

General purpose digital multimeter for electrical and electronic testing

Ideal for quick verifications and field service

Presents a large white LED backlight for working in poorly lit areas

Measures AC and DC voltage to 600V

Measures AC and DC current to 10A (20 A overload for 30-seconds max)

Product overview: Fluke 115 True-RMS Digital Multimeter

The Fluke 115 is the compact, general purpose troubleshooting tool for field service technicians
For general purpose electrical and electronic test requirements, the Fluke 115 True RMS digital multimeter provides the perfect answer. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications.
Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V environments.
Other useful features:

Measures resistance, continuity, frequency, and capacitance

Provides Min/Max/Average with elapsed time to record signal fluctuations

Comes with a holster with probe holders for easy storage

Features a compact ergonomic design for one-handed operation

Fits into optional ToolPak™ magnetic hanger for hands-free operation

CAT III 600 V safety rated

Specifications: Fluke 115 True-RMS Digital Multimeter

Specifications

Maximum voltage between any terminal and earth ground
600 V

Surge protection
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2

Display
Digital: 6,000 counts, updates 4 per second

Bar graph
33 segments, updates 32 per second

Operating temperature
-10°C to + 50°C

Storage temperature
-40°C to + 60°C

Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61

Battery life
400 hours typical, without backlight

Accuracy Specifications

DC millivolts
Range/resolution
600.0 mV / 0.1 mV

Accuracy
± ([% of reading] + [counts]): 0.5% + 2

DC volts
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V

Accuracy
± ([% of reading] + [counts]): 0.5% + 2

AC millivolts1 True RMS
Range/resolution
600.0 mV / 0.1 mV

Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

AC volts1 True RMS
Range/resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V

Accuracy
1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

Continuity
Range/resolution
600 Ω / 1 Ω

Accuracy
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.

Ohms
Range/resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ

Accuracy
0.9% + 1

Range/resolution
40.00 MΩ / 0.01 MΩ

Accuracy
5% + 2

Diode test
Range/resolution
2.00 V / 0.001 V

Accuracy
0.9% + 2

Capacitance
Range/resolution
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF

Accuracy
1.9% + 2

Range/resolution
> 1000 μF

Accuracy
5% + 20%

Lo-Z capacitance
Range
1 nF to 500 μF

Accuracy
10% + 2 typical

AC amps True RMS
(45 Hz to 500Hz)
Range/resolution
6.000 A / 0.001 A
10.00 A / 0.01 A

Accuracy
1.5% + 3
20 A overload for 30-seconds max

DC amps
Range/resolution
6.000 A / 0.001 A
10.00 A / 0.01 A

Accuracy
1.0% + 3
20 A overload for 30-seconds max

Hz (V or A input)2
Range/resolution
99.99 Hz / 0.01 Hz
999.9 Hz / 0.01 Hz
9.999 kHz / 0.001 kHz
50.00 kHz / 0.01 kHz

Accuracy
0.1% + 2

1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.

Mechanical & General Specifications

Size
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

Weight
550 g

Warranty
3 years

Reference Specific ReferencesCondition New product Andrew U03/20/2020Fluke 115 True-RMS Digital Multimeterdigital multimeterWrite your reviewFluke 115 True-RMS Digital MultimeterQuality12345Delivery12345Communication12345Pricing12345Title for your review*Your review*Required fields* Send or Cancel

Reviews
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.

Fluke 115 True-RMS Digital Multimeter 1,000.00
Home Shop Cart Account
Shopping Cart (0)

No products in the cart. No products in the cart.