Evikon E2218 Humidity & Temperature Transmitter Specifications
Sensor: Digital combined RH and T sensor
Measurement range: 0…100 %RH, -40…+85 °C or -40…+125 °C
Calculated parameters: Dew point, absolute humidity
Resolution: 0,1 %RH / 0,1 °C
Accuracy: ±2,5 %RH / ±0,3 °C ±1,8 % RH / ±0,3 °C on request
Response time: ~15 seconds
Self-diagnostics: Full functionality check at start-up
Warm-up time: ≤ 1 s
Power supply: 11…30 VDC, nominal 24 VDC or 24 VAC ±10%
Power consumption: < 1,5 VA
Digital interface: RS485, Modbus RTU protocol
Analog outputs: 2 × 4-20 mA / 0-10 V, user-settable, freely configurable scales
Fieldbus interface: RS485, Modbus RTU protocol
Cable connections: Screwless terminal blocks
Probe connector: Round industrial M12, IP68
Enclosure: Grey ABS, wall mount, protection class IP65
Dimensions: H82 × W80 × D55 mm
Operating environment: industrial indoor and outdoor places
Operating conditions: -40...+85 °C, 0...100 %RH
Standard probe: Ø16×L90 mm, M12 plug, HT-RP16 -40...+85 °C
Probe extension cables: RPEC-2: PVC, length 2,5 m RPEC-5: PVC, length 5,0 m
Microprobe: st. steel Ø4×L50 mm, -40...+85 °C, HT-RP04 attached PVC cable 2 m or 5 m
Heavy-duty probe: Ø16×L90 mm, -40...+125 °C, HT-RP16H attached PTFE cable 2 m or 5 m, M12 plugReference Specific ReferencesCondition New productDownloadEvikon E2218 Data SheetEvikon E2218 Humidity & Temperature Transmitter Data SheetDownload (314.94k)Evikon E2218 User ManualEvikon E2218 Humidity & Temperature Transmitter User ManualDownload (688.04k)Evikon E2218 EC ConformityEvikon E2218 Humidity & Temperature Transmitter EC Declaration of ConformityDownload (304.84k) Andrew U07/01/2021customer supportFor quality, genuineness, fast delivery and good customer support, I recommend industry safety Nigeria as No: 1 in meeting all of that needWrite your reviewEvikon E2218 Humidity & Temperature TransmitterQuality12345Delivery12345Communication12345Pricing12345Title for your review*Your review*Required fields* Send or Cancel