Description

General Information

Extended Product Type:
EK1000-40-11 220-230V 50Hz / 240V 60Hz

Product ID:
SK827044-AL

EAN:
7320500194249

Catalog Description:
EK1000-40-11 220-230V 50Hz / 240V 60Hz Contactor

Long Description:
A 4-pole Contactor suitable for Distribution and Rail way applications AC and DC switching. Operated with control voltage, versions from 24?.690 AC, 50/60 Hz and 24-220 V DC

Categories

Products ? Low Voltage Products and Systems ? Control Products ? Contactors ? Block Contactors

Technical

Number of Main Contacts NO:
4

Number of Main Contacts NC:
0

Number of Auxiliary Contacts NO:
1

Number of Auxiliary Contacts NC:
1

Rated Operational Voltage:
Main Circuit 1000 V

Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ?C 1000 A

Rated Operational Current AC-1 (Ie):
(1000 V) 40 ?C 1000 A

(1000 V) 60 ?C 800 A

(1000 V) 70 ?C 720 A

(690 V) 40 ?C 1000

(690 V) 55 ?C 800

(690 V) 60 ?C 800 A

(690 V) 70 ?C 720

Rated Short-time Withstand Current (Icw):
at 40 ?C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 15 min 1200 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 min 3400 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 s 6800 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 30 s 4400 A

Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour

Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V

acc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):
8 kV

Mechanical Durability:
5 million

Maximum Mechanical Switching Frequency:
3600 cycles per hour

Coil Operating Limits:
(acc. to IEC 60947-4-1) Uc (at ? ? 70 ?C)

Rated Control Circuit Voltage (Uc):
50 Hz 220 ? 230 V

60 Hz 240 V

Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 125 V?A

Holding at Max. Rated Control Circuit Voltage 60 Hz 140 V?A

Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V?A

Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V?A

Operate Time:
Between Coil De-energization and NC Contact Closing 10 ? 20 ms

Between Coil De-energization and NO Contact Opening 13 ? 23 ms

Between Coil Energization and NC Contact Opening 25 ? 55 ms

Between Coil Energization and NO Contact Closing 30 ? 60 ms

Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

Connecting Terminals (delivered in open position) Main Poles:
Flat type c/w screws and bolts

Terminal Type:
Main Circuit: Bars