Description

Why Buy From Hospitalsstore.com?

Brand : ALLIED MEDICAL
Model : Syrn200 Syringe Pump
Allied Syrn 200 syringe pump has been designed to combine the high level of safety and performance with the simple & reliable operation. Syrn 200 offers a comprehensive range of features making it ideal for general, critical care & neonatal infusion where accuracy is important.

Allied Syringe Pump, Syrn200?Specifications:-
Pump Type 😕 Syringe Pump
Pumping Method 😕 Syringe Driven
Flowrate Range 😕 0.1-150.0 ml/Hr (5ml), 0.1-300.0 ml/Hr (10ml), 0.1-600.0 ml/Hr (20ml), 0.1-900.0 ml/Hr (30ml), 0.1-1500.0 ml/Hr (50ml), 0.1-1500 ml/Hr (100ml)
Parameter Combination Setting 😕 4 Programmable Modes, Type I: Set Simple Flow Rate only, Type II: Set Flow Rate & Target Volume, Type III: Set Flow Rate & Target Time, Type IV: Dosage Weight Mode
Applicable 😕 5ml, 10ml, 20ml, 30ml, 50ml, 100ml Syringe Syringe from any brand.
Accuracy :- Mechanical Accuracy ?1%, Including Syringe ?2%
Purge/Bolus Rate:- 100ml up to 1500ml/h, 50(60)ml up to 1500ml/h, 30ml up to 900ml/h, 20ml up to 600ml/h, 10ml up to 300ml/h, 5ml up to 150ml/h
KVO :- 0.1 ml to 1 ml or pre-defined 1ml /h automatically opens one pre-set volume is completed
Volume Range:- 0.1 999 ml (0.1 ml step)
Elapsed Time :- Visual Display of Elapsed time from 00.00 to 99.59(hrs.min)
Drug Library :- Up to 50 drug name display (upgradable to 100 Drugs)
Event Log :- 300 event logs & automatic recording of last infusion settings
Drug Library :- up to 50 drug name display (upgradable to 100 Drugs)
Event Log :- 300 event logs & automatic recording of last infusion settings.
Voice Alarms :- Near Empty (3 mins. before the end of Syringe), Battery Low 10 mins. before full discharge, Operation of Battery, AC power failure, End of Syringe, Occlusion (Syringe Blocked), Wrong Setting, Volume Limit, Syringe Improperly Installed
Power Supply :- ?AC Power source 110V to 240V / 50Hz, an Automatic changeover to internal Battery at less than 180V. Rechargeable battery with backup of 6 hrs@ 5ml/hr flow rate, Optional: Extended Battery Back up for 12 hrs
Fuse :- T 50 mA / 250 V
Power Consumption :- 12 V DC input to use in an ambulance, AC power source 0.1 Amps (Max), 30VA (maximum consumption).
Dimension (mm):- 275mm x 210mm x 122mm
Weight :- 2.0 kg
Interface :- Com Port, USB Port (optional)
Operation Temperature Requirements: Ambient Temperature: (+)5 – (+)40, Relative Humidity: 20% – 90%, Atmosphere Pressure: 86kPa – 06kPa
Storage Temperature Requirements :- Ambient Temperature: (-)30 – (+)55, Relative Humidity: 20% – 95%, Atmosphere Pressure: 70kPa – 106kPa
Standard :- IEC 60601-1:1990, IEC 60601-1-2:2007, IEC 60601-2-24:1998
Alarms:
Near Empty (3 mins before end of Syringe)
Battery Low (10 mins before full discharge)
Operation status of battery
AC power failure
End of Syringe
Occlusion (Syringe Blocked)
Setting Error
Volume Limit
Syringe Improperly Installed