Accurate measurement from only a single drop of sample onto HORIBA's original flat sensor. LAQUAtwin product line-up offers easy, quick, and reliable measurement of 8 parameters. It brings new dimension to your water quality testing.
The LAQUAtwin 4M kit offers extreme flexibility, designed to give you optimal configuration options and ensuring you have all test equipment and solutions at hand when needed.
The removable inlays offer space to up to 4 additional meters. Add a plant sap kit to convert the meter into a mobile agriculture lab.
Create your own kit based on your application requirements.
Add 1, 2, 3 or even 4 meters, choose from pH, EC, TDS, Salt and ionized Calcium
Add a plant sap test box making to kit a powerful agriculture support tool
Removable foam inlays
Light weight, only 870 grams with 4 meters inside
Tough, giving protection to your meters
Over 100 possible meter and accessory configurations
Warranty: 2 years - meter; 6 months - sensor
Packed in handy carrying case
Supplied with 4 meters (NO3-11, NA-11, CA-11 and K-11), 2 standard solutions per meter (14ml each), 8 x CR2032 batteries, 2 droppers, 60ml rinse bottle and instruction manual
Specifications
Model
LAQUAtwin 4M Kit
Description
LAQUAtwin 4M Kit
Article number
1300083234
Items in package
NO3-11, NA-11, CA-11 and K-11
2 standard solutions per meter (14ml each),
8 x CR2032 batteries,?
2 droppers,?
60ml rinse bottle,
Instruction manual
Material case
Polypropylene
Weight?
438 gr (case + foam)
870 gr (complete kit)
10 to 25%: 1%
Dimensions
27 x 23 x 7 (cm)
Servicing Servicing Options Available
?
Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate.
?
The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration.
Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available.
?
A typical preventative maintenance service includes the following:
Inspection and testing of the unit
Dismantling, cleaning and inspection of the key parts
Correction of minor defects including adjustments if necessary
Reassembly and testing
Take post adjustment / cleaning readings
Supply of calibration certificate
Return of the item to you (back to base services)
?
Request a quote for your servicing requirements today.
Quote Request LAQUAtwin Measurements LAQUATWIN Three Step Measurement
Follow simple, good testing procedures for accurate and dependable results:
Calibrate correctly
Avoid mixing samples and standards
Always keep the sensor clean
1 Calibrate
Always ensure the sensor is clean before calibrating. If not, clean thoroughly with water (don?t worry, LAQUAtwin meters are completely waterproof!). Place some standard solution on the sensor and press the calibration button. Once the smiley face appears, indicating that calibration is complete, wash off the standard solution with water and dry with a clean, soft tissue.
2 Test
LAQUAtwin meters only need a tiny amount of sample - so no beaker is necessary. Fill the sensor with the sample and when the smiley face appears, the measurement is complete.
3 Clean
Clean the sensor thoroughly with water, ready for the next test. When the sensor is nearing the end of its usable lifetime, it can be replaced;
You don?t need to replace the meter.
Sensors will need to be replaced after approx.
1500 measurements or when calibration cannot be completed. Sensors are sold separately and are easily removed and replaced.
?
LAQUATwin One meter Six Different Methods
Choose the best method according to your sample, your situation and your needs.
Immersion: When you?re in the lab, you can test the sample in a beaker. Ensure the sensor guard sliding cap is open.
Scoop: Use as a scoop to test water, for example from a river.
Drops: LAQUAtwin meters can measure sample volumes as low as 0.05 mL. Place a drop of the sample onto the sensor with a pipette. Using the HORIBA sampling sheet, volumes down to 0.05 mL can be tested (except for conductivity measurements).
Solid samples: Foods containing some moisture can be tested by placing a small piece directly onto the sensor.
Powders: LAQUAtwin meters can also test dry powders. Simply place the powder sample onto the sensor, and drop on your defined volume of pure water.
Paper and textiles: To test sheets of paper and textiles, cut up the sample into small pieces and place directly onto the sensor. Drop on your defined volume of pure water.
LAQUAtwin sampling sheet.
The sampling sheet allows trace volumes to be analysed. For example, you can even measure the pH of human skin by wiping with a sampling sheet soaked in pure water, and placing it on the sensor. Using the HORIBA sampling sheet, volumes down to 0.05 mL can be tested (except for conductivity measurements). Horiba Electrode Selection General Laboratory and Field Samples
Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.?
The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.?
Gel-filled pH electrode?does?not require?refilling.
ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples.
Examples below:
9651-10D (for field-testing)
9625-10D (for general-purpose use)
9615S-10D Standard ToupH electrode (for general laboratory application)
9415-10C Standard ToupH electrode (for general laboratory application)
Precise Measurement
High stability is required for precise measurement.
The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement.
9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples)
9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples)
6367-10D (for high accuracy pH measurement)
Smaller Volume Samples
The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement.
ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals.
Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.?
Examples below:
9618S-10D Micro ToupH electrode (for low-volume samples)
9418-10C Micro ToupH electrode (for low-volume samples)
9680S-10D Long ToupH electrode (for large containers and long tubes)
9480-10C Long ToupH electrode (for large containers and long test tubes)
6069-10C (for very slender test tubes)
Low Conductivity Samples
pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging.
The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples.
9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples)
9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples)
9630-10D (for low conductivity samples)
Solid and Semi-solid Samples
Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement.
Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.?
ISFET electrodes can also be used in food processing and other applications where glass is prohibited.
6252-10D (for food samples)
6261-10C (for flat surface measurement)
Request Information...
For more information on this product please click the Request information button below and we will get back to you as soon as we can.
Request information
Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget.
Your product or service requirements
Performance criteria
Budget constraints
Site access
Project timeframes
Services available
Environmental factors
Please click the Request Consultation button below and we will get back to you as soon as we can.
Request Information
The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120
Feefo Reviews Related Blogs Conveniently Measure Sodium in Chilli Sauce with the LAQUAtwin Na-11 Pocket Meter Chilli sauces often contain significant amounts of sodium due to dissolved salts. The LAQUAtwin Na-11 pocket meter is a handy device that quickly and accurately measures the sodium content, displaying the result in parts per million (ppm) or mg/L within seconds.4 days ago Question: How can I measure the salinity of Brine? Answer: a Brinometer! Brine is simply defined as a solution of salt in water. It has a wide variety of uses from the transport of thermal energy, de-icing the roads or in cooking to preserve meat or vegetables. The low levels of salinity commonly?found in?food or seawater can be tested in a number of ways such as on the Laqua Twin sodium meter?,?Laqua Twin salt meter?or for a multi-pa...8 years ago Product Attachments Horiba LAQUAtwin Pocket Water Quality Meters (3.14 MB) LAQUAtwin K-11 User Manual (1.41 MB) HORIBA LAQUA Product Brochure (15.04 MB) LAQUAtwin Ion Sensor Maintenance Procedures (1.39 MB) LAQUAtwin pH Sensor Maintenance Procedures (1.44 MB) Soil Nitrate Measurement for Determination of Plant-AvailableNitrogen (1.98 MB) LAQUAtwin Conductivity Sensor Maintenance Procedures (1.34 MB) Soil Salinity Measurement in Almond Orchard (5.01 MB) Nitrate Measurement in Turf Grass (2.37 MB) Rapid In-Field Determination of Nitrogen in Onions (1.74 MB) LAQUAtwin Technical Tips (3.35 MB) LAQUA Electrodes and Accessories (5.14 MB) LAQUA Range Brochure (24.74 MB) LAQUAtwin Na-11 User Manual (1.41 MB) LAQUAtwin Nitrate Ion Meter User Manual (1.46 MB) LAQUAtwin Ca-11 Calcium Meter User Manual (1.52 MB)