Description FURNACE CERAMIC MUFFLE LT9/11/SKM/B510, TMAX.1100 lift d lift door, protective gas connection, hole for thermocouple in furnace door The muffle furnace L 9/11/SKM is particularly recommended for heat treatment of aggressive substances. The furnace has a ceramic muffle with embedded heating from four sides. The muffle furnace thus combines a very good temperature uniformity with excellent protection of the heating elements from aggressive atmospheres. Another aspect is the smooth, nearly particle free muffle (furnace door made of fiber insulation), an important quality feature. Standard Equipment Tmax 1100 °C Muffle heated from four sides Furnace chamber with embedded ceramic muffle, high resistance to aggressive gasses and vapours Dual shell housing made of textured stainless steel sheets with additional fan cooling for low surface temperature Exclusive use of insulation materials without categorization according to EC Regulation No. 1272/2008 (CLP) Optional flap door (L) which can be used as work platform or lift door (LT) with hot surface facing away from the operator Adjustable working air inlet in the door Exhaust air outlet in rear wall of furnace Controller B510 (5 programs with each 4 segments) Solid state relays provide for lownoise operation Defined application within the constraints of the operating instructions NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive Additional Equipment Chimney, chimney with fan or catalytic converter Over-temperature limiter with adjustable cutout temperature as temperature limiter to protect the furnace and load Protective gas connection to purge with non-flammable protective or reaction gases (not available in combination with chimney, chimney with fan or catalytic converter) not gas tight Manual or automation gas supply system Port for thermocouple in the rear wall or in the furnace door Process control and documentation via VCD software package for monitoring, documentation and control Specification Modell Tmax Inner dimensions in mm Volume Outer dimensions2 in mm Connected Electrical Weight Heating time in °C1 w d h in l W D H load in kW connection* in kg in min4 L 9/11/SKM 1100 230 240 170 9 490 505 580 3.4 1-phase 50 75 LT 9/11/SKM 1100 230 240 170 9 490 505 580+3203 3.4 1-phase 50 75 1Recommended working temperature for processes with longer dwell times is 1000 °C*Please see page 75 for more information about supply voltage 2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. 3Including opened lift door 4Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE)Sku: 1701820085-132
FURNACE CERAMIC MUFFLE LT9/11/SKM/B510, TMAX.1100 – Available On Request, Prices in Dollars
₦8,367.12 -
Description FURNACE NCAT 240V CE ASPHALT Accommodate larger sample testing and reduce labor and cost with the Thermo Scientific™ NCAT Asphalt Content Furnace, which uses an environmentally friendly, cost-effective ignition method to determine asphalt content by eliminating the cost of solvent and solvent disposal. Cost analysis has shown that the average asphalt producer can pay for the cost of the furnace in as little as 26-32 weeks based on solvent cost-savings alone. Key Features Asphalt content of bituminous paving mixtures is accurate to 0.11% Accommodates samples up to 5000g Operating Features Automatic mode: endpoint is detected and software ends the test, prints the results and beeps until STOP is pressed to unlock door (in accordance with AMRL specifications) Manual mode: endpoint is detected and furnace begins to beep but continues to test until STOP is pressed to unlock door, then and results print Furnace software automatically compensates for weight change due to sample and basket assembly temperature change Compensation is computed for each sample load tested (i.e, a fixed number is not assigned to a given range of load sizes) Positive or negative correction factors are accepted for use with mixes containing hydrated lime Endpoint within 0.01% of the sample weight is automtically detected Sample stability is reached once endpoint criterion is met for three consecutive minutes during the test Endpoint sensitivity is adjustable from 0.01% to 0.5% Software computes test results as calibrated asphalt content per total weight of HMA sample or bitumen ratio per weight of dry aggregate 24-hour/7-day timer can be programmed to preheat furnace RS-232 port provides data interface with a PC for graphical data analysis Savings and Convenience Larger sample testing reduces total samples needed for testing each day, reducing labor and costs Ignition method reduces testing time when compared to solvent extraction: a 1200 to 1800g asphalt sample can be tested in 30 to 45 min. Internal scale monitors sample weight throughout the process, saving technician time and increasing productivity, as samples need not be removed and weighed Standard 30A electrical service is used (50A service costs more to install and operate) Modular design of refractory embedded heating elements provides extended service life and inexpensive, easy replacement Safety No exposure to harmful solvents Automatic door-lock prevents door opening during critical test time, protecting operator and ensuring test integrity High temperature afterburner is used with a proprietary ceramic filter to reduce ignition process emissions by up to 95% Independent laboratory study, conducted with the California Transportation Department in accordance with California EPA guidelines, showed emissions from the furnace during the ignition test were within EPA parameters A laboratory hygiene study, conducted in accordance with OSHA guidelines, proved the system poses no health threats during proper use Compatible with: Accessory start-up kit (AY1087X1) Specifications Accuracy 0.11% Amperage 23 A Analysis Time 30 to 45 min. (1200 to 1800 g sample) Depth (English) Interior 14 in. Depth (Metric) Interior 35.5 cm Dimensions (D x W x H) Interior 14 x 14 x 14 in. (35.5 x 35.5 x 35.5 cm) Dimensions (L x W x H) Exterior 25.75 x 21.75 x 36.75 in. (65.4 x 55.2 x 93.3 cm) Height (English) 36.75 in. Height (English) Interior 14 in. Height (Metric) 93.3 cm Height (Metric) Interior 35.5 cm Length (English) 25.75 in. Length (Metric) 65.4 cm Power Consumption 4800 w Scale Sensitivity Endpoint: 0.01 to 0.5% Shipping Weight (English) 280 lb. Shipping Weight (Metric) 127 kg Voltage 240 V Width (English) 21.75 in. Width (Metric) 55.2 cm Width (Metric) Interior 35.5 cm Temperature (Metric) 200°C to 650°C Type Asphault Content FurnaceSku: 1701820079-131
FURNACE NCAT 240V CE ASPHALT – Available On Request, Prices in Dollars
₦20,410.38 -
-
Description Fusible Fittings 316 SS Material, Pipe Plug, 1/4 NPT ConnectionSku: 1701820069-129
Fusible Fittings – Available On Request, Prices in Dollars
₦3.00 -
Description FW25Si1 Reagents Silica reagentSku: 1701820063-128
FW25Si1 Reagents – Available On Request, Prices in Dollars
-
Description FW25Si2 Reagents Silica reagentSku: 1701820057-127
FW25Si2 Reagents – Available On Request, Prices in Dollars
-
Description PRODUCT DESCRIPTION G&W and Eastimoldn Type Recloser (F5851-32K) USED WITH Cooper power/Eaton Form 3, Form 4, Form 5, Form 6 SEL-351R; SEL-651R; SEL-351R Falcon Beckwith Electric M-7976 Accessory for F6Sku: 1701820053-126
G&W and Eastimoldn Type Recloser (F5851-32K) – Available On Request, Prices in Dollars
₦0.00 -
Description Galactomannan Assay Kit The Galactomannon test kit is suitable for the measurement and analysis of Galactomannan in food and plant products.Sku: 1701820047-125
Galactomannan Assay Kit – Available On Request, Prices in Dollars
-
Description Galactose dehydrogenase (soil prokaryote) Content: 200 Units Shipping Temperature: Ambient Storage Temperature: 2-8oC Formulation: In 3.2 M ammonium sulphate Physical Form: Suspension Stability: Minimum 1 year at 4oCSku: 1701820028-122
Galactose dehydrogenase (soil prokaryote) – Available On Request, Prices in Dollars
-
Description Galactose dehydrogenase – Galactose mutarotase High purity Galactose dehydrogenase (Escherichia coli) / Galactose mutarotase (Escherichia coli) for use in research, biochemical enzyme assays and in vitro diagnostic analysis. Can be employed for the rapid determination of D-galactose or L-arabinoseSku: 1701820037-123
Galactose dehydrogenase – Galactose mutarotase – Available On Request, Prices in Dollars
-
Description Product Description stant body with a high ingress protection rating IP67. Geiger counter watch aGent-R is designed for detection and evaluation of gamma radiation using four-level threshold alarm system. LED and vibrating alarms warn about threshold levels exceeding. The function of non-stop counter performance monitoring guarantees the accuracy of measurement results. aGent-R is designed for emergency services, MES units and law enforcement agencies. Due to its simplicity, convenience and reliability the radiation detection watch became also popular among people who use it in everyday life. Purpose of Use Detection of the increased levels of gamma radiation and their estimation by means of the four-level threshold alarm system. Features Wrist warning device. Non-stop performance monitoring of the warning device. LED and vibrating alarm of threshold levels exceeding with the option to turn off the vibrating alarm. Non-stop performance monitoring of the built-in Geiger-Muller counter. Manual control of the built-in vibration instrument and residual capacity of batteries with the corresponding LED indication. Periodic vibrating and LED alarm when residual battery capacity becomes less than 10 %. Automatic vibrating and LED alarm when residual battery capacity is less than 5 %, with the following switching-off of the warning device. Two АААА batteries. Shock-resistant plastic housing with IP67 ingress protection rating. Specifications Dynamic range of gamma radiation registration from 10 μR/h to 1000 R/h. Energy range of gamma radiation registration from 0.05 to 3.0 MeV. Threshold level values of gamma radiation dose rate: – 100 μR/h; – 1.0 mR/h; – 100 mR/h; – 10 R/h; Relative error in threshold levels determination ± 25 %. Time of continuous operation with new batteries – not less than 1300 hours*. Operating temperatures range – from -20 to + 50 °С. Weight – 80 g. Dimensions without a strap – 55×55×27 mm. Mean time between failures – not less than 6000 hours. Average service life – not less than 6 years. Average shelf life – not less than 6 years. Delivery Kit “aGent-R” gamma radiation warning device; batteries; leather case with a clip; operating manual; packing box.Sku: 1701820021-121
Gamma radiation warning device “aGent-R” – Available On Request, Prices in Dollars
₦360.80 -
Description Product Description A compact search device with telescopic tube for quick detection and localization of gamma and beta radiation sources. 5 seconds are enough for quick evaluation of gamma background with 4 built-in Geiger-Muller counters. A big display with luminescent backlight simultaneously indicates units of measurement, measurement errors, threshold level and real time. Analog indicator of radiation intensity facilitates localization of radiation sources. The device has a built-in memory for 1200 measurements and 999 objects of inspection. STORA-TU can also transfer measurement results to smartphones and tablets running Android OS in real time. With the help of GS Ecotest application this information is processed, displayed in a user-friendly way and stored in a special database. The GS Ecotest application can be downloaded from Google Play for free. Measurement results can also be transferred to a personal computer through the Bluetooth channel. Purpose of Use Measurement of gamma and X-ray radiation ambient dose equivalent rate (DER). Measurement of surface beta-particles flux density. Real time and date display, alarm clock function. Features Damp and dustproof body IP54. Big display with luminescent backlight. Simultaneous indication of measurement units, measurement errors, threshold level and real time. Analog twelve-segment indicator of registered radiation intensity. Ability to perform measurements with a preset error. Four-level indication of battery discharge. Built-in memory which allows storing up to 1200 measurements and 999 numbers of the measured objects with ability to view the recorded information on the display of the device. Mode of PC connection via Bluetooth. Three independent measuring channels with alternate indication of data on the single liquid crystal display. Prompt evaluation of gamma background within 5 seconds. Automatic subtraction of gamma background at measurement of beta contamination. Four built-in gamma, beta sensitive Geiger-Muller counters. Automatic setting of measurement intervals and ranges. Audio signaling of each detected gamma-quantum and beta-particle that can be switched off. Two-tone audio alarm of exceeded programmed threshold levels. Operation with telescopic tube. Two AAA batteries. Specifications Measurement ranges and main relative errors Gamma and X-ray radiation ambient dose equivalent rate (137Cs) µSv/h 0.1…999.9; % ±(15+2/H*(10)),where H*(10) is a numeric value of measured DER equivalent to µSv/h Beta-particles flux density (90Sr+90Y) 1/(cm2×min) 5…100 000; % ±(20+200/φβ), where φβ is a numeric value of measured beta-particles flux density equivalent to part./(cm²×min) Energy ranges of measurement and energy dependence: – Gamma and X-ray radiation MeV 0.05…3.0;±25% – Beta radiation MeV 0.5…3.0 Resolution of threshold level programming for: dose rate flux density µSv/h 10³/(cm²×min) 0.01 0.01 Time of continuous operation with fully charged batteries* hours 2 500 Operating temperature range °С -20…+50 Weight kg 0.44 Dimensions mm 160×75×35 Delivery Kit RKS-01 “STORA-TU” radiometer-dosimeter; case of close and waterproof cloth used to carry the device and telescopic tube on a shoulder; telescopic tube; operating manual; “Cadmium ECOMONITOR” software; packing box.Sku: 1701820016-120
Gamma, beta radiation radiometer-dosimeter RKS-01 “STORA-TU” with Bluetooth module, telescopic tube and case – Available On Request, Prices in Dollars
₦1,263.60 -
-
500162 cas: 93?92?5 fema: 2684 ec: 202?288?5flavis: 09.178coe: 573jecfa: 801Sku: 1713927979-862
Gardenol (Styrallyl Acetate)
₦100.00