Description

The Portable ICU Ventilator is designed to work in a highly versatile environment. Whether you need Invasive or Non-Invasive ventilation the Meditec 1700 delivers. Power-packed with a range of Ventilation modes to suit individual preferences the Portable ICU Ventilator is ideal for use in an ICU, Intra-Hospital transport, Air, and Ground transport. Simplicity, In-built air supply, versatility, and affordable cost of ownership make Meditec 1700 the obvious choice.
Feature of Allied M1700 Portable ICU Ventilator:
Invasive as well as Non-Invasive VentilationPressure & Flow waveforms with Trends FacilityAltitude compensationFiO2 MeasurementSuitable for both dual as well as single limb breathing circuitsPatient History storage capabilityAutomatic Parameters adjustment of the patient according to Height & WeightBattery Backup: 4 HrsExtended battery backup (optional): 4 HrsTouchscreen, as well as the knob, operatedShock Resistant (Drop Test compliant)Nebulizer: 10 180 minutesInspiration hold: Measures patient? lung compliance and resistance, Elasticity, Time constantKey lock: Key & LCD Touch Screen LockWaveform freeze: Freezes the waveformAlarm silence: Mutes audible alarms for 2 minutesAlarm Reset: Clears visual indicators and messagesSpecification of?Allied M1700 Portable ICU Ventilator:
BrandAlliedModel?M1700Inspiratory time0.1 – 24 secTrigger SensitivityPressure trigger OFF,0.5 to 20 cm H2O, Flow trigger OFF,0.5 to 20 lpmWeight7.8 kgs. (main unit with battery)Tidal Volume50 – 2500 mlInspiratory Pressure5 – 80 cm H2O (Peep+Pins less than 100cm H2O)Respiratory Rate2 – 80 bpmOperation Temperature10 – 40 Degree CRelative Humidity10 – 85%Display Screen8 Inch Screen with Touch Control & Rotary KnobParametersSet Parameters / Measured Parameters / Alarm Status / IE RatioWaveformPressure-Time, Flow-Time, Volume-TimeLoopPressure-Volume, Flow-Volume, Minute VolumeModesPACV,PSIMV,VACV,VSIMV,AUTO (Emergency Quick Start),Spont+,PRVCPressure support0 – 60 cm H2O (PEEP+PSV less than 100cm H2O)Rise Time in PCVFast,Medium,Slow (0 – 2 sec)Apnea Time2 – 60 secApnea BackUp TypePACV,VACV ModeTrend72 hrsEnable inhalation to trigger En sense10 – 80% of Inhalated volumeExhalation trigger Sensitivity Ex trig10 – 80% of peak flow in exhalationInspiratory Pressure limit5 – 80 cm H2O in PRVCSuitable Body WeightVolume Mode 10 – 150 kg,Pressure mode 1 – 150 kgNebulizer time10 – 180 mins (3 Hours)Altitude Volume Compensated(-)100 – 5000 [m]Room Air Temperature0 – 50 Degree CPowerAC 100 – 230v 50 – 60 Hz,DC 10.8v – 8.8APower Backup180 mins. internal battery backupPEEP and CPAP0 – 50 cm H2ODimensions250mm x 156mm x 371mm (W x D x H)