Description

Allied Volumatric Infusion PUMP Description :-

Display
LCD

Weight
2.2 Kg

Allied Infuser 120 is a microprocessor controlled high-precision, intelligent drip type infusion pump, which is capable of accurately controlling the delivery rate of disposable IV set and monitoring the infusion course.
It is especially suitable for clinical treatments which require continuous and precisely controlled infusion at a constant rate. It is widely used in internal medicine, surgical, pediatrics, obstetrics, ICU, CCU wards, operating rooms and other clinical infusion treatments.

Product Features:-

4.3? Large LCD display, with back light, suitable for working in various ambient light conditions
With special heating function, suitable for infusion in winter
Remote control makes operation more convenient
Real time monitoring at the central station through wireless transmission
Simple and convenient operation
Three working modes: Rate/Volume/Time mode
Purge, KVO function
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle
Air Bubble Detector
Saves last Infusion and bolus rate
Adjustable Mounting Clamps

Flow Management:-

Adjustable Drop Rate Range: 1 ? 400 drops/min (step: 1 drop/min)
Adjustable Volume Rate Range: 1 ? 1200 ml/h (when 1-99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h)
Flow Precision: within ?2% (using calibrated high-quality IV set) Mechanical precision: ?2%
Purge Rate: up to 800 ml/hr
KVO Rate: 1 ml/h (1 ? 300 ml/h); 3 ml/h (greater than 300ml/h)
Infusion Volume Range: 1 ml ? 9999.9 ml (step: 0.1 ml)
Maximum Accumulated Volume: 9999.9 ml (step: 0.1 ml)
Time Range: 1 min ? 9999 min (step: 1 min)

Alarms:-

?(i) Infusion Complete? (ii) Empty? (iii) Misoperation? (iv) Faulty Signal (v) Occlusion (vi) Air Bubble (vii) Door Open? (viii) Low Battery (ix) Setting Error (x) AC Off (xi) Timeout

Specifications:-

Pump Type: Drip type infusion pump
Pumping Method: Peristaltic
Adjustable Drop Rate Range: 1 – 400 drops/min (step: 1 drop/min)
Adjustable Volume Rate Range: 1 – 1200 ml/h (when 1 – 99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h)
Flow Precision: ?2% (using calibrated high quality IV set)
Mechanical Precision: ?2%
Purge Rate: up to 800 ml/hr
KVO Rate: 1 ml/h (1 – 300 ml/h); 3 ml/h (greater than 300 ml/h);
Volume Range: 1 ml – 9999.9 ml (step: 0.1 ml), 9999.9 ml (step: 0.1 ml)
Infusion Maximum Accumulated Volume: 1 min – 9999 min (step: 1 min)
Time Range: 1 min – 9999 min (step: 1 min)
Occlusion Alarm Threshold: High: 800 mmHg – 200 mmHg (106.7kPa – 26.7kPa), Medium: 500 mmHg – 100 mmHg (66.7kPa – 13.3kPa) Low: 300 mmHg – 100 mmHg(40.7kPa – 13.3kPa)
Air Bubble Detector: Ultra sonic wave, sensitivity: 25 L
Alarms Infusion Complete: Empty, Mis-operation, Faulty Signal, Occlusion, Air Bubble, Door Open, Low Battery, Setting Error, AC Off, Timeout
Power Supply: AC 85 – 265V, 50/60Hz
Fuse: F1AL/250V (F indicates fast, L indicates low breaking capacity), 2 pieces (installed inside pump)
Power Consumption 40vA
Internal Battery: Rechargeable battery with backup of 5hours @25ml/hr
Dimension (mm): 188(L) x 198(W) x 228(H)
Interface: Com Port