General Information
Extended Product Type:
EK1000-40-11 220-230V 50Hz / 240V 60Hz
Product ID:
SK827044-AL
EAN:
7320500194249
Catalog Description:
EK1000-40-11 220-230V 50Hz / 240V 60Hz Contactor
Long Description:
A 4-pole Contactor suitable for Distribution and Rail way applications AC and DC switching. Operated with control voltage, versions from 24?.690 AC, 50/60 Hz and 24-220 V DC
Categories
Products ? Low Voltage Products and Systems ? Control Products ? Contactors ? Block Contactors
Technical
Number of Main Contacts NO:
4
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Rated Operational Voltage:
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ?C 1000 A
Rated Operational Current AC-1 (Ie):
(1000 V) 40 ?C 1000 A
(1000 V) 60 ?C 800 A
(1000 V) 70 ?C 720 A
(690 V) 40 ?C 1000
(690 V) 55 ?C 800
(690 V) 60 ?C 800 A
(690 V) 70 ?C 720
Rated Short-time Withstand Current (Icw):
at 40 ?C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 15 min 1200 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 min 3400 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 s 6800 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 30 s 4400 A
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Mechanical Durability:
5 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) Uc (at ? ? 70 ?C)
Rated Control Circuit Voltage (Uc):
50 Hz 220 ? 230 V
60 Hz 240 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 125 V?A
Holding at Max. Rated Control Circuit Voltage 60 Hz 140 V?A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V?A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V?A
Operate Time:
Between Coil De-energization and NC Contact Closing 10 ? 20 ms
Between Coil De-energization and NO Contact Opening 13 ? 23 ms
Between Coil Energization and NC Contact Opening 25 ? 55 ms
Between Coil Energization and NO Contact Closing 30 ? 60 ms
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals (delivered in open position) Main Poles:
Flat type c/w screws and bolts
Terminal Type:
Main Circuit: Bars