Socorex Initial Pack – Acura Electro 926 XS Electronic Micropipette 0.5-10?l for tip style Ultra 10?l.
Each initial package contains all components needed to get started. Thereafter, additional pipettes can be purchased alone and charged on the existing stand.
Set includes:
1x Acura?electro926XSpipette
1x Qualitix?pipette tips samples
1x QC certificate
1x Operating instructions
1x Pipette charging stand
1x Fast charger with AC adapter and cord
1x Additional battery pack
₦444,435.00 Save:₦88,885.00(17%)
Socorex Initial Pack - Acura Electro 926 XS Electronic Micropipette 0.5-10?lThe Acura Electro 926 range includes a microprocessor-controlled motor and rechargeable battery pack. It also contains an intuitive software avoiding any complicated programming steps. Eight models cover the volume range 0.1 to 1000 ?L. Additional interchangeable volumetric modules available as accessories.
Reduced shaft length and conical end improve driveability
Easy access to microtubes and microplates
Optional longer volumetric modules
Simple conversion of volumes with interchangeable volumetric volumes
Unsurpassed metrological performance and stability
Features:
Natural ergonomics - The Acura?electro offers shape, balance and working ergonomics resembling those of a manual instrument.
Pipetting cycle counter - A simple double click gives access to the number of pipetting cycles performed since last zeroing.
Unique "left or right" display reading - Display converts instantly to right or left side reading. All information clearly presented and visible at a glance during programming, pipetting and calibration steps.
Variable speed - Located on the front side, speed selector allows swift change even during the pipetting process. In addition, slow speed access at any time by gentle touch of start button.
Interchangeable volumetric modules - One control unit fits a choice of 27 volumetric assemblies available separately. This greatly extends working possibilities and makes electronic pipetting affordable to all budgets. Disassembling and re-assembling without any tool contributes towards maximal flexibility. Calibration specificities of extra modules - as set by factory QC or by pipette owner - are retained in instrument memory.
Long working autonomy - NiMH battery pack exchangeable instantly. Fast battery charging ( 3000 consecutive pipetting cycles). Battery charge level clearly visible on display. Automatic energy saving stand-by when unused.
Adjustable tip ejection - Maximal efficiency obtained with a large surface, ergonomically located ejector button. The shaft height adjustment system called JustipTM (4 mm span) - controlled by efficient click-stops - allows a wide selection of tips to tightly fit the nozzle.
Time efficient maintenance - Pipette construction limits maintenance to a minimum - no tool required to remove volumetric module. The pipetting cycle counter facilitates maintenance monitoring. Whenever sterilisation is needed, volumetric modules can be autoclaved at 121?C / 250?F.
Calibration- Control software gives immediate access to calibration menu. Performance check possible over two or three independent volumes (Vmin, Vmid and Vmax). New settings entered directly from the keyboard. Error message warns of any inaccurate plunger movement.
Pipetting modes
Mode
Action
Suitable for
Forward
Aspiration and pipetting of set volume
All daily pipetting applications
Reverse
Aspiration in excess followed by dosing of set volume
Viscous, volatile and foaming liquids.
Enhances reproducibility below 20 ?L
Stepper
Tip filling and step-by-step distribution
Aliquot samples
Dilution
Aspiration of 2 or 3 different volumes for restitution in one shot
Dilution samples
Tactile
Monitoring of aspiration or distribution while touching activation button
Measurement of unknown volumes,
gel loading or titration
Mixing
"Up and down" liquid flow in the tip / vial
Sample mixing in small tubes
Specifications
Performance information
Volume
Inaccuracy (E%)
Imprecision (CV%)
Range
Division
Min. vol.
Mid. vol.
Max. vol.
Min. vol.
Mid. vol.
Max. vol.
0.1 - 2 ?L
0.01 ?L
<? 2.5 %1)
<? 1.2 %
<? 0.9 %
< 2.5%1)
< 1.5 %
< 0.8 %
0.5 - 10 ?L
0.05 ?L
<? 1.2%2)
<? 0.8 %
<? 0.6 %
< 1.5 %2)
< 0.7 %
< 0.35 %
0.5 - 10 ?L
0.05 ?L
<? 1.2%2)
<? 0.8 %
<? 0.6 %
< 1.7 %2)
< 0.8 %
< 0.4 %
1- 20 ?L
0.1 ?L
<? 1.2%2)
<? 0.6 %
<? 0.5 %
< 1.2 %2)
< 0.4 %
< 0.3 %
2.5 - 50 ?L
0.25 ?L
<? 1.0 %2)
<? 0.6 %
<? 0.5 %
< 0.7 %2)
< 0.3 %
< 0.25 %
5 - 100 ?L
0.5 ?L
<? 1.0 %2)
<? 0.6 %
<? 0.5 %
< 0.7 %2)
< 0.3 %
< 0.2 %
10 - 200 ?L
1.0 ?L
<? 1.0 %2)
<? 0.6 %
<? 0.4 %
< 0.6 %2)
< 0.2 %
< 0.15 %
50 - 1000 ?L
5.0 ?L
<? 0.8 %2)
<? 0.5 %
<? 0.4 %
< 0.4 %2)
< 0.15 %
< 0.1 %
Performance values obtained with bidest water at constant temperature (? 0.5?C) comprised between 20 and 25?C,in accordance with ISO 8655. Results can be improved by individual calibration in each mode.
1) measured at 0.5 ?L 2) measured at 10% of nominal volume
Request Information...
For more information on this product please click the Request information button below and we will get back to you as soon as we can.
Request information
Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget.
Your product or service requirements
Performance criteria
Budget constraints
Site access
Project timeframes
Services available
Environmental factors
Please click the Request Consultation button below and we will get back to you as soon as we can.
Request Information
The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120
Feefo Reviews Related Blogs Air cushioned vs positive displacement pipettes
Pipettes are used to transfer specific volumes of solutions from one place to another. These are used mainly in analytical and microbiology, cell biology, DNA analysis, PCR etc, where small volumes are used. Pipettes can come in fixed volumes or as variable volume so you can set the desired volume. Variable volume pipettes come in a particular volume range.
Varied volume pipettes by Socore...2 years ago
Description
Reviews
There are no reviews yet.