Description
Overview
Essential details
Warranty:
1 year
Customized support:
OEM
Place of Origin:
Shandong, China
Brand Name:
Winner 2005A
Size Range:
0.01μm/0.1μm-1000μm
Standard:
ISO13320-1:1999,GB/T19077.1-2008, Q/0100JWN001-2013
Channels Number:
40 pcs
Accuracy error:
<1%
Repeatability error:
<1%
Light Source:
He-Ne laser
Dispersion Method:
Dry-turbulence dispersion mode
Operation Mode:
Manual / one key test
Optical Path Calibration System:
manual
Dispersing Medium:
Compressed air
Supply Ability
Supply Ability
500 Set/Sets per Month
Packaging & delivery
Packaging Details

The laser particle size analyzer package is plywood box.

Port

Qingdao/Hongkong

Picture Example:
Lead time:
Quantity(sets)1 – 2>2
Lead time (days)5To be negotiated
Video Description

00:00

00:00

Winner 2005A/Winner 2005B
Product Description
Winner2005A/B intelligent full automatic laser diffraction particle size analyzer with MIE scattering theory to precisely test the particle size distribution from 0.01/0.1μm to 1000μm. It adopts dual laser beam and built-in sample preparation system, Intelligent operation, very simple to use for engineer, offer accurate and reliable data,built-in side wide-angle detector, make sure get 0.01 micron particles scattering angles.

Main Features

1) Light path: Adopt converging light Fourier transform light path,measure range expanded from 0.01μm-1000μm.

2)Intelligent full automatic operation mode realize one key test, automatically supply water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.

3) Automatic Optical path alignment System,
The precision of four hybrid stepping motor in the automatic system of optical components, micro precision of 0.01μm, the instrument of light path is always at its best to eliminate manually on the light path and the troubles and difficulties but also enhance the accuracy and stability of test results.


4)Full built-in Sample dispersion system,
Auto wet dispersion system,SOP realize one key operation.
set mechanical stirring, ultrasonic dispersion, and circulation path in one, It ensures particles uniform dispersion and distribution,avoids many bad phenomenon, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, it guarantees the representativeness of test result.

5) Analysis software:adopt unconstrained free fitting patent technology make particle analysis not be restricted by any functions, truly reflect particle size distribution.

6) High sensitive photo detectos gathering all the particles scattering signals, ensure the good accuracy.

7)Output parameters:(D50, D03, D06, D10, D16, D25, D75, D84, D90, D97,D98,set any value, S/V, D[3,2],D[4,3] )

Specification
Model Name
Winner2005A/Winner2005B
Standard
ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013
Principle
MIE Scattering Principle
Size range
0.01μm-1000μm/0.1μm-1000μm
Photodetectos
90pcs/87 pcs
Accuracy
≤0.5% (Deviation of D50 on national standard sample)
Repeatability
≤0.5% (Deviation of D50 on national standard sample)
Laser
Semi conductor Laser λ= 636.5nm, p>2mW
Service time>25000 hour
Wet dispersion
Ultrasonic
Frequency:40KHz Power:35W, Time: ≥1S
Agitator
Revolutions Speed: 0-3000RPM (Adjustable)
Circulation
Rated Flow:8L/min Rated Power:10W
Sample tank
Volume: 350mL
Operation mode
Manual and Full automatic
Optical alignment system
Full automatic optical path alignment system
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple-language Support
Multiple language Support
Intelligent operation
Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor
Report Items
Particle size distribution table&graph, average diameter, Median diameter, SSA, etc.
Testing speed
<2min/time (including all the procedures)
Running temperature
15 ℃ -35 ℃
Humidity
<85%
Outer dimension
L85cm*W39cm*H45cm
Net weight
40Kg

Principle

Test Analysis View

Application

Winner2005A/Winner 2005B is widely used for cement, ceramic, medicine, dope, dye, padding, chemical products, catalyst, braize, dust, additive,pesticide, explosive, graphite, photosensitive material, fuel, metal and nonmetal powder, calcium carbonate, kaolin and other powder materials.
Company Profile
Jinan Winner Particle Instrument Co., Ltd. have have been specialized in particle size analyzer for more than 30 years, since we undertake National Science Project-particle size analyzer development in 1985.
We are the 1st manufacturer to produce Nano-particle size analyzer in China.

Our particle size analyzer will enable you understand materials well, and save your time and cost. Reliable data enables scientists, researchers and engineers to evolve formulations and processes with confidence. Our products guide research and product development, manage and control manufacturing quality, and optimize output.

By now, We have Laser Particle size analyzer, Image particle size analyzer, Spray particle size analyzer, particles counter and Nano-particles size analyzer and so on.

We are dedicated to offer you the best particle size analysis solution.
Your satisfaction is our eternal target!

Certifications
Exhibition
Our Customers

Cooperative Partner

Our Team

Our goal is to provide super quality and competitive price laser particle size analyzer for clients all over the world!
We created more than 10 first particle size analysis technology in China!
Recommend Products

Quality Assurance


1. Strictly conforming to ISO9001-2000 quality management system.

2. Strict control from purchasing materials, process inspection to final particle size distribution test.

3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.
After Sale Service


1.Operation demo video CD will be offered.

2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
Packing & Delivery
Winner particle testing equipment is Wooden box package.


We would ship machine by DHL, FeDex, China express, by sea and by air.

FAQ

Purchase laser particle size analyzer need know points:

1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.

2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.

3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.

More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!
Reviews
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.