Customer matched zone "Lagos Delivery Options"
Sort by:
125681–125696 of 362918 Results
-
Description FLOW METERS INSERTION-VERSION. VA 500 – Flow meter for compressed air and gases VA 500 Special features: • Including temperature measurement • RS 485 interface, Modbus-RTU as standard • Integrated display for m³/h and m³ • Applicable from 1/2” to DN 1000 • Easy installation under pressure • 4…20 mA analogue output for m³/h or m³/min • Pulse output for m³ or M-Bus (optional) • Inner diameter adjustable by means of keys • Flow meter can be reset • Adjustable by means of keypad on the display: Reference conditions, °C and mbar, 4…20 mA scaling, pulse weight FLOW METERS INSERTION-VERSION VA 500 DESCRIPTION VA 500 flow sensor in basic version: Standard (92.7 m/s), probe length 220 mm, without display Bi-directional measurement – includes 2 x 4…20 mA analogueue outputs and 2x pulse outputs. These do not apply to Ethernet (PoE) and M-Bus OPTIONS FOR FLOW METERS INSERTION-VERSION VA 500 Display Max version (185 m/s) High-speed version (224 m/s) Low-speed version (50 m/s) 1% accuracy of m.v. ± 0.3 % of f.s. Ethernet interface for VA 500/520 and FA 500 Ethernet interface PoE for VA 500/520 and FA 500 M-Bus board for VA 500/520 and FA 500 Probe length 120 mm Probe length 160 mm Probe length 300 mm Probe length 400 mm Probe length 500 mm Probe length 600 mm G 1/2″ NPT male thread High-pressure protection recommended for installation from 10 to 50 bar (for VA 400/500) ISO calibration certificate (5 calibration points) for VA sensors Gas type:___ (specify gas type when placing order) Gas mixture:___ (specify gas mixture when placing order) Real gas adjustment 3200 0015 Special cleaning oil and grease free (e.g. for oxygen applications) LABS and silicone-free version including cleaning oil and grease-free Additional calibration curve stored in the sensor (can be selected via display) Certificate of originSku: 1701821391-363
FLOW METERS INSERTION-VERSION. VA 500 – Flow meter for compressed air and gases – Available On Request, Prices in Dollars
₦2,836.68 -
FLOW SPLITTER paediatric (Sureflow FM069-2)Sku: 1723595067-2777
FLOW SPLITTER paediatric (Sureflow FM069-2)
₦0.00 -
SaleThe U-50 Multi-Meter Series Features ?Control Unit ?Control Unit Design for Field Operations Auto-calibration feature provides hassle-free calibration of pH, dissolved oxygen, conductivity, turbidity and depth. Shock resistant cover designed for rough treatment in the field and is easily cleaned. Cable can be easily connected and disconnected with quick-connect fitting. ?Data Management Auto hold function freezes average data values on the screen to offer more time to verify or transcribe data. Diagnostic functions notify the user of errors. Integral USB connection for data transfer to a PC. Selectable measurement units allow the operator to report data without the need to convert data to desired units of measure. ?Sensor Probe Unit ?Multiple Sensors Housed in Each Probe Multiple sensors allow for the measurement of?11 parameters simultaneously?(pH, pH(mv), ORP, DO, COND, Salinity, TDS, Seawater Specific Gravity, Temperature, Turbidity, Water Depth). Turbidity sensor U-53 conforms to US EPA method 180.1. Precision has been improved over conventional instruments. The model U-53 high precision filed replaceable turbidity sensor with wiper has a resolution of 0.01 NTU. Turbidity sensor of U-54 conforms to EN ISO 7027. The model U-54 has a resolution of 0.01 NTU. Improved stability of the dissolved oxygen sensor has been achieved with a new 3 electrode design for fast response and polarographic sensor for ease of maintenance. pH and ORP electrodes can be replaced individually to reduce replacement costs LAQUA U-50 - Sensors Housing ? ? ? Multiple sensors allow for the measurement of 11 parameters simultaneously. (pH, pH (mv), ORP, DO, COND, Salinity, TDS, Seawater Specific Gravity, Temperature, Turbidity, Water depth) Turbidity Sensor U-53 conforms to US EPA method 180.1. Precision has been improved over conventional instruments. The Model U-53 high precision field replaceable turbidity sensor with wiper has a resolution of 0.01 NTU. Turbidity sensor of U-54 conforms to EN ISO 7027. The model U-54 has a resolution of 0.01 NTU. Improved stability of the dissolved oxygen sensor has been achieved with a new 3 electrode design for fast response and polarographic sensor for ease of maintenance. pH and ORP electrodes can be replaced individually to reduce replacement costs. ? U-5X Series Comparison List LAQUA U-50 Multi Meters & Accessories ? U-50 Multi Meters U-51(2M) 3200164509 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp. U-51(10M) 3200164510 U-52(2M) 3200164501 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(LED) U-52(10M) 3200164502 U-52(30M) 3200164503 U-52G(2M) 3200156563 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(LED), Depth, GPS U-52G(10M) 3200164499 U-52G(30M) 3200164500 U-53(2M) 3200164506 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(tungsten), Depth U-53(10M) 3200164507 U-53(30M) 3200164508 U-53G(2M) 3200158178 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(tungsten), Depth, GPS U-53G(10M) 3200164504 U-53G(30M) 3200164505 U-54(2M) 3200323680 Parameters: pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(tungsten), Depth* U-54(2M) doesn't have the feature of water depth. U-54(10M) 3200323681 U-54(30M) 3200323683 U-54G(2M) 3200323686 Parameters: pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(tungsten), Depth, GPS* U-54(2M) doesn't have the feature of water depth U-54G(10M) 3200323687 U-54G(30M) 3200323688 Supplied with 1 x pH 4 buffer solution (500ml), 1 x pH reference solution (330 - 250ml), 1 x DO solution set (50ml internal solution, sandpaper, syringe), cleaning brush ? U-50 Probes only U-51- 2m 3200237465 Sensor Probe with 2m Cable Assemblies include: Sensor probe Guard., conductivity U-51-10m 3200237464 Sensor Probe with 1Om Cable Assemblies include: Sensor probe Guard., conductivity U-52- 2m 3200237467 Sensor Probe with 2m Cable Assemblies include: Sensor probe Guard, conductivity. U-52-10m 3200237466 Sensor Probe with 1Om Cable Assemblies include: Sensor probe Guard, conductivity U-52-30m 3200237468 Sensor Probe with 30m Cable Assemblies include: Sensor probe Guard, conductivity U-52G- 2m 3200237470 Sensor Probe with 2m Cable Assemblies include: Sensor probe Guard, conductivity, Water depth U-52G-10m 3200237469 Sensor Probe with 1Om Cable Assemblies include: Sensor probe Guard, conductivity, Water depth U-52G-30m 3200237471 Sensor Probe with 30m cable include: Sensor probe Guard, conductivity, Water depth U-53/U-53G- 2m 3200237473 Sensor Probe with 2m Cable Assemblies include: Sensor probe Guard, conductivity, Water depth U-53/U-53G-1 Om 3200237472 Sensor Probe with 1Om Cable Assemblies include: Sensor probe Guard, conductivity, Water depth U-53/U-53G-30m 3200237474 Sensor Probe with 30m Cable Assemblies include: Sensor probe Guard, conductivity, Water depth ? U-50 electrodes and consumables 7112 3014057312 pH Sensor: 7112 7113 3200170923 pH Sensor ToupH: 7113 7313 3200170920 ORP Sensor: 7313 7543 3200170924 DO Sensor: 7543 7210 3200043582 Reference Electrode Tip: 7210 Liquid Junction for 7210 3200043587 Liquid Junction for 7210 (2pcs) 7800 3200172803 U-52 Turbidity Cell: 7800 7801 3200172800 U-53 Turbidity Cell: 7801 DO Membrane cap 3200170194 DO Membrane cap (3pcs) 306 3200170938 Internal Solution for DO: 306 PH PROTECT CAP 3200175019 pH Sensor Protect Cover (3pcs) DO PROTECT CAP 3200175020 DO Sensor Protect Cover (3pcs) O-RING SET 3200169520 O-rinQ for pH/ORP sensor (10pcs) O-RING SET 3200169426 O-rinq for DO sensor (10pcs) O-RING SET 3200169376 O-rinq for Reference electrode (1Opes) RUBBER CAP SET 3200169428 Rubber Cap for sensor Quard (8pcs) WIPER RUBBER 3200169789 Wiper rubber (3pcs) SPONGE BRUSH 3200169531 Sponge Brush ? Accessories U-5030 3200174772 U-50 - Carrying Case for U-50: U-5030 KU-20-2 3200174823 U-50 - Communication Cable(USB2.0, 2m) w/ software Flow Through Cell 3200156570 U-50 - Flow Cell for U-50 Probe Guard for U-50 3200167002 U-50 - Probe Guard for U-50 Calibration Beaker 3200156572 U-50 - Calibration Beaker for U-50 U-5000 3200324195 U-50 - Control Unit for U-50 without GPS: U-5000 U-5000G 3200324196 U-50 - Control Unit with GPS for U-50: U-5000G U-50EP 3200358528 U-50 - External power for U-50: U-50EP USB connector 3200225292 U-50 - Leak test for U-50 (ETO) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments LAQUA Multi Meters U-50 Series (3.76 MB) LAQUA Multi Meters U-50 Series Instruction Manual (2.36 MB)Sku: 1723966663-425
Flow Through Cell – U-50 – Flow Throuqh Cell for U-50
₦357,080.00Original price was: ₦357,080.00.₦297,565.00Current price is: ₦297,565.00.₦357,080.00Original price was: ₦357,080.00.₦297,565.00Current price is: ₦297,565.00. Add to basket Quick View -
-
-
Description Flow-/ consumption meter VA 570-Inline flow meter Flow-/ consumption meter VA 570 Special measurement technology features: • 4 values on the display: Flow, total consumption, velocity, tem-perature. Units freely adjustable • All measured values, settings such as gas type, inner diameter, serial number and so on can be accessed via Modbus-RTU • Comprehensive diagnostic functions readable on the display or remote access via Modbus such as calibration cycle, error codes, serial number • Notification in case of exceeding the calibration cycle • Standard version accuracy 1.5% of m.v. ± 0.3% of f.s. • Precision version accuracy 1.0% of m.v. ± 0.3% of f.s • Measuring span of 1 : 1000 (0.1 up to 224 m/s) • Configuration and diagnosis via display, hand-held device PI 500, PC service software on-site • Gas type (air, nitrogen, oxygen, argon and so on) freely adjust-able via PC service software or external device DS 400, DS 500, PI 500 • Reference conditions °C and mbar/hPa freely adjustable • Zero-point adjustment, leak flow volume suppression • Pressure loss negligible Flow-/ consumption meter VA 570 Special mechanical features: • Robust impact-proof aluminium die cast housing for the outdoor area IP 67 • All wetted parts made from stainless steel 1.4571 • On request with DVGW approval for natural gas (up to 16 bar) • Pressure range up to 16 bar, special version up to 40 bar • Temperature range up to 180 °C • No moveable parts, no wear • Sensor tip very robust, easy to clean • Housing rotatable, display rotatable by 180°Sku: 1701821385-362
Flow-/ consumption meter VA 570-Inline flow meter – Available On Request, Prices in Dollars
₦2,778.81 -
Description Flow-Through Conductivity Cells/TetraCon® DU/T Four electrode plastic flow-through measuring cells with low-polarization graphite electrodes for applications in closed circuits Suitable for flow-through measurement in the lab For medium and high conductivity Also to test special systems Flow measuring cells by WTW for medium and high conductivity are suitable for extensive measuring series in the lab but also for the maintenance and measurement of cleaning solutions in special systems. Technical Data TetraCon® DU/T, TetraCon® DU/TH Measuring range 1 µS/cm … 1 S/cm Temperature range 0 … 60 °Sku: 1701821379-361
Flow-Through Conductivity Cells . TetraCon® DU/T – Available On Request, Prices in Dollars
₦1,174.95 -
Description Flow-Through Conductivity Cells/TetraCon® DU/TH Four electrode plastic flow-through measuring cells with low-polarization graphite electrodes for applications in closed circuits Suitable for flow-through measurement in the lab For medium and high conductivity Also to test special systems Flow measuring cells by WTW for medium and high conductivity are suitable for extensive measuring series in the lab but also for the maintenance and measurement of cleaning solutions in special systems. Technical Data TetraCon® DU/T, TetraCon® DU/TH Measuring range 1 µS/cm … 1 S/cm Temperature range 0 … 60 °Sku: 1701821373-360
Flow-Through Conductivity Cells . TetraCon® DU/TH – Available On Request, Prices in Dollars
₦1,232.60 -
Description Product Description Features Fit a Wide Range of Tubing Diameters – 1/4″ to 1/2″ Flow – No Flow Non – Intrusive-Senses right through tubing Mounting Bracket All Plastic Design Simple to Install Tube Thickness – Heavy Walled Low Voltage Light weight Very Accurate Perfect for Dosing Pumps – Metering WillSku: 1701821362-358
FLOW/LEVEL SWITCH – Available On Request, Prices in Dollars
₦343.82 -
-
-
SaleSku: 1707220394-354
Flowel Plus (Tamsulocin 0.4mg+ Dustasteride 0.5mg) x 10Caps
₦21,000.00Original price was: ₦21,000.00.₦20,300.00Current price is: ₦20,300.00.₦21,000.00Original price was: ₦21,000.00.₦20,300.00Current price is: ₦20,300.00. Add to basket Quick View -
Sale
Flowel plus – request current price on allschoolabs.com
₦21,000.00Original price was: ₦21,000.00.₦20,300.00Current price is: ₦20,300.00.₦21,000.00Original price was: ₦21,000.00.₦20,300.00Current price is: ₦20,300.00. Add to basket Quick View -
FLOWEL TAMSULOSIN HYDROCHLORIDE CAP 0.4MGSku: 130
FLOWEL TAMSULOSIN HYDROCHLORIDE CAP 0.4MG
₦1,650.00 -
Tamsulosin belongs to a group of medicines called alpha blockers. It?s used to treat men with symptoms of an enlarged prostate (benign prostate enlargement). It?s also occasionally taken to treat kidney stones and prostatitis.Sku: 1736041921-1443
FLOWEL TAMSULOSIN | Exp. Date: 12/27
₦11,700.00