Sku: 1701821421-368
Flow Calibration with Certificate – Available On Request, Prices in Dollars
₦550.03 -
-
Sku: 1701821416-367
Flow Controller with One-Touch Fittings, Inline Type – Available On Request, Prices in Dollars
₦87.16 -
Description CS-iTEC FLOW DIRECTONAL SWITCH FOR COMPRESSED AIR AND GASES The thermal mass flow direction switch S 409 allows the detection of an existing flow and the direction of the flow. It can be used in compressed air and non-corrosive gases. The sensor element is very robust and completely of stainless steel. Through a 1/2” G-type ball valve the switch can be inserted into the pipe under pressure. The flow and direction information is output through 2 normally open relay switches. This signals can be transferred to the CS flow sensor to activate and deactivate the flow measurement depending on the flow direction. Application Connection of S 330 to S 450 via flow switch Connection of S 330 to two S 400 with flow switch Product Features Detects smallest changes <0.1 m/s referred to 20 °C and 1000 mbar No mechanical wear parts Easy installation under pressure All parts which are in contact with flow medium are made of stainless steel Technical data Technical data S 409 Detection range 0.1 … 185 Nm/s Sensor 2 x Pt 1000 Medium air, gases Medium humidity <100% (no condensation) Medium temp. -20 … 80 ºC Ambient temp. -20 … 70 ºC Operating pressure 0 … 16 bar Power supply 24 VDC, 60 mA Output 2 x Relay, 60V, 1A Process connection 1/2” G typeSku: 1701821410-366
Flow Direction Switch for Compressed Air / Gases S 409 – Available On Request, Prices in Dollars
₦954.46 -
SaleA pipe network is a system of interconnected pipes used for fluid transport. A pipe network can be used for a variety of purposes, such as water supply, sewage disposal, heating and cooling systems, and industrial process piping. Flow in a pipe network is determined by the principles of fluid mechanics, including conservation of mass and energy, as well as the properties of the fluid and the geometry of the pipes. Here are some common methods used to analyze flow in a pipe network:
- Conservation of mass: The principle of conservation of mass states that the mass of fluid entering a pipe junction must equal the mass of fluid exiting the junction. This principle is used to calculate the flow rates of fluid in the pipes of the network.
- Conservation of energy: The principle of conservation of energy states that the total energy of the fluid in a pipe network must remain constant. This principle is used to calculate the pressure drops and head losses in the pipes.
- Pipe network modeling: Pipe network modeling involves creating a mathematical model of the pipe network using computer software, such as EPANET or Bentley Systems. The model can be used to simulate the flow rates and pressures in the network under different operating conditions.
- Pipe sizing: Pipe sizing involves selecting the appropriate pipe diameter for each section of the network to ensure that the flow rate and pressure drop are within the design specifications.
- Pump selection: Pump selection involves selecting the appropriate pump type and size to provide the necessary flow rate and pressure to the network.
- Flow measurement: Flow measurement involves using flow meters, such as differential pressure meters, magnetic flow meters, or ultrasonic flow meters, to measure the flow rates of fluid in the pipes of the network.
Sku: flow-in-pipe-networkFlow in Pipe Network
₦600,000.00Original price was: ₦600,000.00.₦520,000.00Current price is: ₦520,000.00.₦600,000.00Original price was: ₦600,000.00.₦520,000.00Current price is: ₦520,000.00. Add to basket Quick View -
SaleFlow indicators give precise visual indication of the flow velocity of liquids or gases being transported through hose connections.The impeller starts to rotate at a given flow rate (see details under each individual type).Optional colours for ease of?identification?for different hose lines. Feefo ReviewsSku: 1723931334-407
Flow Indicator Paddles
₦50,000.00Original price was: ₦50,000.00.₦6,880.00Current price is: ₦6,880.00.₦50,000.00Original price was: ₦50,000.00.₦6,880.00Current price is: ₦6,880.00. Add to basket Quick View -
SaleA flow measuring apparatus is a device or system used to measure the rate of flow of a fluid, such as a liquid or gas, through a pipe or conduit. Flow measurement is important in a wide range of applications, including process control, monitoring and optimization of fluid flow, and research in fluid dynamics. Here are some common types and features of flow measuring apparatus:
- Differential pressure flow meters: These flow meters measure the pressure drop across a constriction in a pipe, such as an orifice plate, venturi tube, or flow nozzle, to determine the flow rate. The differential pressure is measured using pressure sensors or a manometer.
- Positive displacement flow meters: These flow meters measure the volume of fluid displaced by a moving element, such as a piston, gear, or rotor, to determine the flow rate.
- Magnetic flow meters: These flow meters use the principle of electromagnetic induction to measure the flow rate of conductive fluids. A magnetic field is generated by coils around the pipe, and the voltage induced in the fluid is proportional to the flow rate.
- Ultrasonic flow meters: These flow meters use ultrasonic waves to measure the flow rate of fluid in a pipe. Ultrasonic waves are transmitted across the pipe and the time of flight of the waves is used to determine the flow rate.
- Thermal flow meters: These flow meters measure the flow rate of gas by sensing the heat transfer between a heated element and the gas stream. The flow rate is proportional to the heat transfer rate.
- Turbine flow meters: These flow meters use a turbine or paddle wheel to measure the flow rate of liquid in a pipe. The rotation of the turbine or paddle wheel is proportional to the flow rate.
- Coriolis flow meters: These flow meters use the principle of Coriolis force to measure the mass flow rate of fluid in a pipe. The fluid is forced to oscillate by vibrating tubes and the phase shift between the input and output signals is proportional to the mass flow rate.
- Volumetric flow meters: These flow meters measure the volume of fluid passing through a pipe over a given time period. Examples include rotameters and variable area meters.
- Portable flow meters: These flow meters are designed to be easily portable and can be used for flow measurement in a variety of applications, including process monitoring and troubleshooting.
Sku: flow-measuring-apparatusFlow Measuring Apparatus
₦650,000.00Original price was: ₦650,000.00.₦550,000.00Current price is: ₦550,000.00.₦650,000.00Original price was: ₦650,000.00.₦550,000.00Current price is: ₦550,000.00. Add to basket Quick View -
Description Flow meter insertion type- VA 520 – Inline flow meter with integrated measuring section, (R 1/4″ DN 8) Flow meter insertion type- VA 520 application-technological features: • Digital interfaces such as Modbus-RTU, Ethernet (PoE) and M-Bus enable connection to higher-level systems such as energy man-agement systems, building management systems, PLC,… • Easy and affordable installation • Units freely selectable via keys on the display m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s, cfm • Compressed air counter up to 1,999,999,999 m³ can be reset to “zero” via keypad • Analog output 4…20 mA, pulse output (electrically isolated) • High measuring accuracy even in the lower measuring range (ideal for leakage measurement) • Negligibly small loss of pressure • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts • Comprehensive diagnostic functions can be read out on the display or remote access via Modbus-RTU such as exceeding max./min values °C, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus Flow meter insertion type- VA 520 display shows 2 values at the same time: • Present flow in m³/h, l/min,… • Total consumption (counter reading) in m³, l • Temperature measurement Readout values in the display can be rotated by 180°, e.g. for overhead installation Flow meter insertion type- VA 520 with a key stroke: • Reset counter reading • Select units • Zero-point adjustment, leak flow volume suppression Flow meter insertion type- VA 520 options: Bi-directional measurement. Blue or green arrows in the display indicate the direction of flow. A meter reading is available for each flow direction.Sku: 1701821404-365
Flow meter insertion type- VA 520 – Inline flow meter with integrated measuring section, (R 1/4″ DN 8) – Available On Request, Prices in Dollars
₦1,429.08 -
Description Flow meter insertion type-VA 550 – Flow sensor for installation in existing compressed air or gas line of 3/4″ to DN 1000 Flow meter insertion type-VA 550–Special measurement technology features: • 4 values on the display: Flow, total consumption, velocity, tem-perature. Units freely adjustable • All measured values, settings such as gas type, inner diameter, serial number and so on can be accessed via Modbus-RTU • Comprehensive diagnostic functions readable on the display or remote access via Modbus such as calibration cycle, error codes, serial number • Notifi cation in case of exceeding the calibration cycle • Standard version accuracy 1.5% of m.v. ± 0.3% of f.s. • Precision version accuracy 1.0% of m.v. ± 0.3% of f.s • Measuring span of 1 : 1000 (0.1 up to 224 m/s) • Confi guration and diagnosis via display, hand-held device PI 500, PC service software on-site • Gas type (air, nitrogen, oxygen, argon and so on) freely adjust-able via PC service software or external device DS 400, DS 500, PI 500 • Reference conditions °C and mbar/hPa freely adjustable• Zero-point adjustment, leak fl ow volume suppression • Pressure loss negligible Flow meter insertion type-VA 550–Flow sensor mechanical features: • Robust impact-proof aluminium die cast housing for the outdoor area IP 67 • All wetted parts made from stainless steel 1.4571 • Suitable as an insertion version for 3/4″ to DN 1000 • On request with DVGW approval for natural gas (up to 16 bar) • Pressure range up to 50 bar, special version up to 100 bar • Temperature range up to 180 °C• No moveable parts, no wear • Sensor tip very robust, easy to clean • Easy installation and removal under pressure via 1/2″ ball valve • Housing rotatable, display rotatable by 180° • Safety ring for installation and removal under pressure • Depth scale for precise installation Flow meter insertion type-VA 550–Flow sensor Optional: Connection to different Bus systems There are different options available for connection to modern Bus systems: • Ethernet interface (Modbus-TCP) / PoE • M-BUS • Modbus-RTU • Profi bus DP interface (in process) • Profi net interface (in process) • HART (in process)Sku: 1701821396-364
Flow meter insertion type-VA 550 – Flow sensor for installation in existing compressed air or gas line of 3/4″ to DN 1000 – Available On Request, Prices in Dollars
₦3,682.43 -
Description FLOW METERS INSERTION-VERSION. VA 500 – Flow meter for compressed air and gases VA 500 Special features: • Including temperature measurement • RS 485 interface, Modbus-RTU as standard • Integrated display for m³/h and m³ • Applicable from 1/2” to DN 1000 • Easy installation under pressure • 4…20 mA analogue output for m³/h or m³/min • Pulse output for m³ or M-Bus (optional) • Inner diameter adjustable by means of keys • Flow meter can be reset • Adjustable by means of keypad on the display: Reference conditions, °C and mbar, 4…20 mA scaling, pulse weight FLOW METERS INSERTION-VERSION VA 500 DESCRIPTION VA 500 flow sensor in basic version: Standard (92.7 m/s), probe length 220 mm, without display Bi-directional measurement – includes 2 x 4…20 mA analogueue outputs and 2x pulse outputs. These do not apply to Ethernet (PoE) and M-Bus OPTIONS FOR FLOW METERS INSERTION-VERSION VA 500 Display Max version (185 m/s) High-speed version (224 m/s) Low-speed version (50 m/s) 1% accuracy of m.v. ± 0.3 % of f.s. Ethernet interface for VA 500/520 and FA 500 Ethernet interface PoE for VA 500/520 and FA 500 M-Bus board for VA 500/520 and FA 500 Probe length 120 mm Probe length 160 mm Probe length 300 mm Probe length 400 mm Probe length 500 mm Probe length 600 mm G 1/2″ NPT male thread High-pressure protection recommended for installation from 10 to 50 bar (for VA 400/500) ISO calibration certificate (5 calibration points) for VA sensors Gas type:___ (specify gas type when placing order) Gas mixture:___ (specify gas mixture when placing order) Real gas adjustment 3200 0015 Special cleaning oil and grease free (e.g. for oxygen applications) LABS and silicone-free version including cleaning oil and grease-free Additional calibration curve stored in the sensor (can be selected via display) Certificate of originSku: 1701821391-363
FLOW METERS INSERTION-VERSION. VA 500 – Flow meter for compressed air and gases – Available On Request, Prices in Dollars
₦2,836.68 -
FLOW SPLITTER paediatric (Sureflow FM069-2)Sku: 1723595067-2777
FLOW SPLITTER paediatric (Sureflow FM069-2)
₦0.00 -
SaleThe U-50 Multi-Meter Series Features ?Control Unit ?Control Unit Design for Field Operations Auto-calibration feature provides hassle-free calibration of pH, dissolved oxygen, conductivity, turbidity and depth. Shock resistant cover designed for rough treatment in the field and is easily cleaned. Cable can be easily connected and disconnected with quick-connect fitting. ?Data Management Auto hold function freezes average data values on the screen to offer more time to verify or transcribe data. Diagnostic functions notify the user of errors. Integral USB connection for data transfer to a PC. Selectable measurement units allow the operator to report data without the need to convert data to desired units of measure. ?Sensor Probe Unit ?Multiple Sensors Housed in Each Probe Multiple sensors allow for the measurement of?11 parameters simultaneously?(pH, pH(mv), ORP, DO, COND, Salinity, TDS, Seawater Specific Gravity, Temperature, Turbidity, Water Depth). Turbidity sensor U-53 conforms to US EPA method 180.1. Precision has been improved over conventional instruments. The model U-53 high precision filed replaceable turbidity sensor with wiper has a resolution of 0.01 NTU. Turbidity sensor of U-54 conforms to EN ISO 7027. The model U-54 has a resolution of 0.01 NTU. Improved stability of the dissolved oxygen sensor has been achieved with a new 3 electrode design for fast response and polarographic sensor for ease of maintenance. pH and ORP electrodes can be replaced individually to reduce replacement costs LAQUA U-50 - Sensors Housing ? ? ? Multiple sensors allow for the measurement of 11 parameters simultaneously. (pH, pH (mv), ORP, DO, COND, Salinity, TDS, Seawater Specific Gravity, Temperature, Turbidity, Water depth) Turbidity Sensor U-53 conforms to US EPA method 180.1. Precision has been improved over conventional instruments. The Model U-53 high precision field replaceable turbidity sensor with wiper has a resolution of 0.01 NTU. Turbidity sensor of U-54 conforms to EN ISO 7027. The model U-54 has a resolution of 0.01 NTU. Improved stability of the dissolved oxygen sensor has been achieved with a new 3 electrode design for fast response and polarographic sensor for ease of maintenance. pH and ORP electrodes can be replaced individually to reduce replacement costs. ? U-5X Series Comparison List LAQUA U-50 Multi Meters & Accessories ? U-50 Multi Meters U-51(2M) 3200164509 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp. U-51(10M) 3200164510 U-52(2M) 3200164501 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(LED) U-52(10M) 3200164502 U-52(30M) 3200164503 U-52G(2M) 3200156563 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(LED), Depth, GPS U-52G(10M) 3200164499 U-52G(30M) 3200164500 U-53(2M) 3200164506 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(tungsten), Depth U-53(10M) 3200164507 U-53(30M) 3200164508 U-53G(2M) 3200158178 Parameters : pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(tungsten), Depth, GPS U-53G(10M) 3200164504 U-53G(30M) 3200164505 U-54(2M) 3200323680 Parameters: pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(tungsten), Depth* U-54(2M) doesn't have the feature of water depth. U-54(10M) 3200323681 U-54(30M) 3200323683 U-54G(2M) 3200323686 Parameters: pH, ORP, DO, conductivity, Salinity, TDS, Seawater, Temp, Turbidity(tungsten), Depth, GPS* U-54(2M) doesn't have the feature of water depth U-54G(10M) 3200323687 U-54G(30M) 3200323688 Supplied with 1 x pH 4 buffer solution (500ml), 1 x pH reference solution (330 - 250ml), 1 x DO solution set (50ml internal solution, sandpaper, syringe), cleaning brush ? U-50 Probes only U-51- 2m 3200237465 Sensor Probe with 2m Cable Assemblies include: Sensor probe Guard., conductivity U-51-10m 3200237464 Sensor Probe with 1Om Cable Assemblies include: Sensor probe Guard., conductivity U-52- 2m 3200237467 Sensor Probe with 2m Cable Assemblies include: Sensor probe Guard, conductivity. U-52-10m 3200237466 Sensor Probe with 1Om Cable Assemblies include: Sensor probe Guard, conductivity U-52-30m 3200237468 Sensor Probe with 30m Cable Assemblies include: Sensor probe Guard, conductivity U-52G- 2m 3200237470 Sensor Probe with 2m Cable Assemblies include: Sensor probe Guard, conductivity, Water depth U-52G-10m 3200237469 Sensor Probe with 1Om Cable Assemblies include: Sensor probe Guard, conductivity, Water depth U-52G-30m 3200237471 Sensor Probe with 30m cable include: Sensor probe Guard, conductivity, Water depth U-53/U-53G- 2m 3200237473 Sensor Probe with 2m Cable Assemblies include: Sensor probe Guard, conductivity, Water depth U-53/U-53G-1 Om 3200237472 Sensor Probe with 1Om Cable Assemblies include: Sensor probe Guard, conductivity, Water depth U-53/U-53G-30m 3200237474 Sensor Probe with 30m Cable Assemblies include: Sensor probe Guard, conductivity, Water depth ? U-50 electrodes and consumables 7112 3014057312 pH Sensor: 7112 7113 3200170923 pH Sensor ToupH: 7113 7313 3200170920 ORP Sensor: 7313 7543 3200170924 DO Sensor: 7543 7210 3200043582 Reference Electrode Tip: 7210 Liquid Junction for 7210 3200043587 Liquid Junction for 7210 (2pcs) 7800 3200172803 U-52 Turbidity Cell: 7800 7801 3200172800 U-53 Turbidity Cell: 7801 DO Membrane cap 3200170194 DO Membrane cap (3pcs) 306 3200170938 Internal Solution for DO: 306 PH PROTECT CAP 3200175019 pH Sensor Protect Cover (3pcs) DO PROTECT CAP 3200175020 DO Sensor Protect Cover (3pcs) O-RING SET 3200169520 O-rinQ for pH/ORP sensor (10pcs) O-RING SET 3200169426 O-rinq for DO sensor (10pcs) O-RING SET 3200169376 O-rinq for Reference electrode (1Opes) RUBBER CAP SET 3200169428 Rubber Cap for sensor Quard (8pcs) WIPER RUBBER 3200169789 Wiper rubber (3pcs) SPONGE BRUSH 3200169531 Sponge Brush ? Accessories U-5030 3200174772 U-50 - Carrying Case for U-50: U-5030 KU-20-2 3200174823 U-50 - Communication Cable(USB2.0, 2m) w/ software Flow Through Cell 3200156570 U-50 - Flow Cell for U-50 Probe Guard for U-50 3200167002 U-50 - Probe Guard for U-50 Calibration Beaker 3200156572 U-50 - Calibration Beaker for U-50 U-5000 3200324195 U-50 - Control Unit for U-50 without GPS: U-5000 U-5000G 3200324196 U-50 - Control Unit with GPS for U-50: U-5000G U-50EP 3200358528 U-50 - External power for U-50: U-50EP USB connector 3200225292 U-50 - Leak test for U-50 (ETO) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments LAQUA Multi Meters U-50 Series (3.76 MB) LAQUA Multi Meters U-50 Series Instruction Manual (2.36 MB)Sku: 1723966663-425
Flow Through Cell – U-50 – Flow Throuqh Cell for U-50
₦357,080.00Original price was: ₦357,080.00.₦297,565.00Current price is: ₦297,565.00.₦357,080.00Original price was: ₦357,080.00.₦297,565.00Current price is: ₦297,565.00. Add to basket Quick View -
-