Customer matched zone "Lagos Delivery Options"
“Cutinorm Soap (100gm) (pack of 3)” has been added to your basket. Continue shopping
“L?Oreal B6 + Biotin Inforcer Conditioner – 200ml” has been added to your basket. Continue shopping
Sort by:
257–272 of 39890 Results
-
SaleManufactured from white LDPE, with optional HDPE lid and mobile support trolley.?Food approvedThe storage bin locks securely onto the trolley for safety. Dimensions 645mm H x 545mm W x 570mm D Feefo ReviewsSku: 1723970201-892
106L Storage Bin
₦54,010.00Original price was: ₦54,010.00.₦45,010.00Current price is: ₦45,010.00.₦54,010.00Original price was: ₦54,010.00.₦45,010.00Current price is: ₦45,010.00. Add to basket Quick View -
SaleFeefo Reviews Product Attachments 3M Fit Test Guide (252.65 kB) The HSE Fit Test Guidance Resource (1.12 MB) More Information More Information ColourWhiteSku: 1723936201-1016
107 Respirator Carry Case – Suitable for Full and Half Masks
₦34,915.00Original price was: ₦34,915.00.₦29,095.00Current price is: ₦29,095.00.₦34,915.00Original price was: ₦34,915.00.₦29,095.00Current price is: ₦29,095.00. Add to basket Quick View -
Portable cylinder manufactured from high quality aluminium and supplied with pin-index toggle valveSku: 1727164257-2144
10L Oxygen Cylinder with Pin-index valve
₦649,999.00 -
Product More SpecificationsMade InChinaThere are no reviews for this product.Write a review Your Name Your ReviewNote: HTML is not translated! Rating Bad Good Captcha Please complete the captcha validation below ContinueSku: 1721375214-10292
10L Steel Oxygen Cylinder white Working pressure: 150bar OD-140mm
₦190.00 -
Sale10 litre plastic bucket availale with a tamper evident lid and a metal handle with roller grip. Made from Polypropylene Copolymer, these robust and airtight buckets are suitable for food products and non hazardous chemicals. Dimensions: Diameter at top - 288mm Diameter at base - 250mm Height - 212mm Can be Autoclaved. Feefo Reviews Related Blogs How can I keep my samples secure and tamper proof? The first stage of any test is to collect a sample. Whether it's water, biological tissues, or a sample from a production line, it must be representative of the bulk and not be altered in order to give accurate results. Most samples will have to be transported after they are collected - this might be just a few meters from a production line to the test room, or could be a lengthy transit fr...9 years ago More Information More Information MaterialPolypropylene (PP)Sku: 1723975447-1459
10L White Bucket with Tamper Evident Lid & Metal Handle
₦9,040.00Original price was: ₦9,040.00.₦7,535.00Current price is: ₦7,535.00.₦9,040.00Original price was: ₦9,040.00.₦7,535.00Current price is: ₦7,535.00. Add to basket Quick View -
Sale10 metre compressed air supply hose with coupling for use with Versaflo Supplied Air Systems S-200. Feefo ReviewsSku: 1723976829-1600
10m CAST with Coupling – Pack of 1
₦92,815.00Original price was: ₦92,815.00.₦77,345.00Current price is: ₦77,345.00.₦92,815.00Original price was: ₦92,815.00.₦77,345.00Current price is: ₦77,345.00. Add to basket Quick View -
SaleHigh temperature, anti-static 10m compressed air supply tube without for use with supplied air systems. Both ends of 3M CASTs have a 3/8" BSP male thread 3M CASTs form an integral part of the system approval process Feefo ReviewsSku: 1723975490-1465
10m Standard Duty Anti-Static High Temperature CAST – Pack of 1
₦267,155.00Original price was: ₦267,155.00.₦222,630.00Current price is: ₦222,630.00.₦267,155.00Original price was: ₦267,155.00.₦222,630.00Current price is: ₦222,630.00. Add to basket Quick View -
Sale10 metre standard duty compressed air supply tube for use with supplied air systems.? Both ends of 3M CASTs have a 3/8" BSP male thread 3M CASTs form an integral part of the system approval process Feefo ReviewsSku: 1723973973-1307
10m Standard Duty CAST – Pack of 1
₦91,860.00Original price was: ₦91,860.00.₦76,550.00Current price is: ₦76,550.00.₦91,860.00Original price was: ₦91,860.00.₦76,550.00Current price is: ₦76,550.00. Add to basket Quick View -
SaleThese synthetic rubber extension hoses allow for remote measurement down manholes and into tanks.Available in 5m, 10m and 30m lengths.NB with the 30m hose only some tubes will still present accurate results - please contact us with further details of your requirements if you need this option. GASTEC Gas detector tubes Gas detector tubes GASTEC gas detector tubes are thin glass tubes with calibration scales printed on them so you can directly read the concentrations of the substances (gases and vapours) to be measured. Each tube contains a particulate matrix (e.g. silica gel, alumina), which binds carefully selected and highly stable detection reagents that are especially sensitive to the target substance to produce a distinct layer of colour change. The tubes are hermetically sealed at both ends. Currently, over 600 types of target gas can be measured. Features On-site measurements can be performed easily by anybody, anytime and anywhere, quickly. Easy-to-check direct reading possible due to calibrated scale directly printed on the tube An extensive measuring range can be obtained by adjusting the sampling volume. For high precision, each production lot is tested and calibrated independently. Each detector tube has its quality control number printed on the tube. Long shelf-life with excellent long-term stability Operating environment Most GASTEC tubes can be used in the temperature range of 0 - 40?C and relative humidity range of 0- 90%. However, a few tubes have different temperature or humidity ranges. Please refer to the instruction manuals before use. Gas sampling pump The handy design GASTEC GV-100 cylinder pump, with an inner capacity of 100mL, weighs only 240g. It is designed for use with almost all GASTEC short-term measurement detector tubes. ? Standards The following table provides an overview and comparison of JIS K 0814 and major international industrial standards. ? ? Standard / Requirements JIS K 0804:2022 ISO17621:2015 lUPAC (published in 1982) ANSl / ISEA 102-1990?(R2015) Sampling pump Volume ??5% ??5mL ??5% ??5% Air leakage ?3% ?3mL/min ? 3%/min ? 3%/min Durability 1000 pump strokes 1000 pump strokes - 100 pump strokes Detector tube Obliqueness of the boundary discolouration ?20% ?20% ?20% ?20% Measurement performance Class A B* ?15%??(Conc. of 33.3% or more of MS***) ?15 to 25%(Conc. of 20 to 33.3% of MS***) ?25%?(Conc. of 20% or less of MS***) (B*+U**) ?30%?(Conc. of 26.7% or more of MS***) ?30 to 50% (Conc. of 16 to 26.7% of MS***) ?50%?(Conc. of 16 % or less of MS***) Class B (B*+U**)?50% ? U**?50% Class A Read value ?? 25% (1, 2 and 5?MPC****) ?? 35% (0.5?MPC****) Class B Read value ?? 35% (0.5, 1, 2 and 5?MPC****) Read value ?? 25% (1, 2 and 5?MPC****) ?? 35% (0.5?MPC****) *B: Bias of the scale reading against the test gas concentration **U: Expanded uncertainty for a detector tube measurement system (The?calculations?of?Expanded?uncertainty?are?different?for?each?standard.) ***MS: Maximum scale value of the detector tube ****MPC: Maximum permissible concentration, e.g. TLVs (Threshold limit values), etc. Standards? JIS:? Japanese Industrial Standard, JIS K 0804: 2022, ?Gas detector tube measurement system ? ISO:? International Organization for standardization, ISO17621: 2015, ?Workplace atmosphere - Short term detector tube measurement systems - Requirements and test methods? lUPAC:? International Union of Pure and Applied Chemistry, ?Performance Standard for Detector Tube Units used to monitor gases?and vapours in working areas? ANSl / ISEA:? American National Standards Institute / Industrial Safety Equipment Association, ANSI / ISEA102-1990 (R2015), ?American National Standard for Gas Detector tube Units - Short Term Type for Toxic Gases and Vapors in Working Environments? GASTEC FAQs What is the purpose of gas detector tubes?? The gas detector tube system is a complete sampling and analysis system for determining hazardous gas and vapour concentrations quickly and easily. The majority of activities that the detector tube system is used for is to carry out spot sampling, e.g. to check the level of hazardous gas within a container that has been unloaded from a ship or for determining the level of hazardous gases present on-site. It is not advised to use detector tubes for personal safety, as they don?t provide an alarm or warning system. What are gas detector tubes? Gas detection or gas detector tubes as they are known, are glass tubes that are filled with a chemical reagent that absorbs and reacts with the target gas or vapour being measured as part of a gas detection programme.? A colorimetric stain (a colour change) is created. For most detector tubes, the concentration is read directly from the measurement scale on each tube. The detector tube system is comprised of a handheld air sampling? pump and detector tubes. How do detector tube system technologies vary?? Gastec and Drager tubes use the same colourimetric technology where the chemical reagent in the gas tube reacts to the gas sample as it is drawn through the tube. The main difference between Gastec and Drager is the gas sampling pump technique. Gastec utilises an effective piston-style pump that requires minimal effort which pulls air through the detector tube. The gas detector tube fits in one end of the Gastec pump. At the other end of the Gastec pump, there is a small handle that comfortably fits between your middle and index finger. This is pulled up to draw the sample and clicks once the sample is complete. Drager utilises a bellow-style pump (shaped similar to a stapler). When the bellows are released, the air is drawn, and the gas sample to be measured is sucked through the detector tube in use. How is gas detected using the gas detector tube system?? The detector tubes are generally supplied in packs of ten and are sealed at both ends. The tips are broken off in operation using a tube tip breaker, a neat function often within the hand pump or otherwise sold as a separate item. Gas detector tubes are used with a handheld air sampling pump.? Depending on the manufacturer, the pump utilises a bellows or piston design. The pump connects to one end of the detector tube, and the user draws a sample of 50ml or 100ml of ambient air. As the gas sample works its way up the tube towards the sampling pump, it reacts with the chemical reagent within the tube. The colour stain produced is proportional in length to the concentration. Using a calibration scale printed on the tube, the concentration may be read immediately without needing?laboratory analysis. The point where this reaction stops is easily read off against markings on the gas detector tube. What range do the detector tubes measure at? For many gases and vapours, several concentration ranges are available (ppm, %, Mg/m3, mg/l), giving you the flexibility to measure both low and high concentrations without sacrificing precision. Which gases do detector tubes detect?? Gas detector tubes are available to measure more than 500 different kinds of gases and vapours, including the following:? Acetaldehyde Acetic Acid Acetone Ammonia Benzene Bromine Carbon Dioxide Fluorine Formaldehyde Hydrogen Hydrogen Chloride Hydrogen Cyanide Hydrogen Sulphide MEK-Methyl Ethyl Ketone Mercaptans Nitrogen Dioxides Oxygen Phosphine Styrene Sulphuric Acid Toluene Xylene What do the most popular detector tubes test for? Hydrogen Sulphide and Carbon Monoxide are our most popular detector tube types. There are 7 variations of Hydrogen Sulphide detector tubes within the standard tubes' classification. The main difference being the range at which they detect. All standard detector tubes are priced at the same price no matter the detection range. There are 8 different Carbon Monoxide detector tube range types. Do detector tubes offer STEL and TWA readings? Short Term Exposure Limit (STEL) detector tubes accurately measure gas concentration for occupational hygiene and compliance with laws and guideline standards. The short-term tubes account for the lion's share of available tubes (standard tubes). Time-Weighted Average (TWA) tubes provide gas samples for up to eight hours. The direct-reading, length of-stain tube shows immediate results and is often worn in a lapel for the duration of the shift/working day.? TWA tubes eliminate laboratory turnaround time and allow you to correct worker exposure problems faster. Do short-term gas detector tubes comply with standards?? Yes, European Standard EN1231 specifies performance requirements and test methods under prescribed laboratory conditions for length-of-stain detector tubes and their associated pump (detector tube measurement system) used for short-term measurements of the concentration of specified chemical agents in the workplace? air. What are the benefits of gas detector tubes?? Detector tubes are most effective for accurate on-the-spot measurements Relatively inexpensive Intrinsically safe method, allowing them to be deployed in all applications where some gas detectors cannot Where are detector tubes used? A number of different job roles for various gas detecting activities uses the gas detector tubes.? Hazardous Materials Response Clean-up of Spills Wastewater Treatment Plants Refineries Leak Detection Marine and Shipping Pharmaceutical Chemical & Fertilizer Fumigation Food & Beverage Industry Power & Steel Plants Municipal Corporations Oil & Gas How much does the gas detector tube system cost?? Following the initial one-off outlay of purchasing an air sampling pump for about ?200, the only ongoing cost is for gas tubes. The gas detector tubes are low cost, with a pack of 10 tubes costing in the region of around ?30. Look out for suppliers that offer detection tubes at one consistent price, which makes it easier for procurement processes. Do I need to perform a pump leak test before using the pump, and how do I do this?? It is very important always to do a leak test every time you are using an air sampling pump to ensure that you get accurate readings. You can confirm that the inlet clamping nut is firmly tightened. After confirming that the pump the handle is fully in (therefore, the guideline on the pump shaft is not seen), insert a fresh unbroken detector tube into the rubber inlet of the pump. Align the guide mark (red line) on the backplate and the guide mark (100) on the handle. Pull out the handle fully along the red guideline on the pump shaft to the lock position, and wait 1 minute. Unlock the handle by turning it for more than 1/4 turns and guide it back gradually.? Confirm the handle returns to the initial position and the guideline on the pump shaft is not seen. When the handle is unlocked, guide it back gradually by applying a little resistance. Otherwise, the handle will spring back due to the vacuum in the pump cylinder and possibly damage internal parts. What to do when my tube shows a blurry result after doing a test?? If you have encountered a blurry discolouration of the chemical reagent in the tube, always take the average between the two points on the detector tube, printed scale where it ended. Is it possible to mix the use of gas detection tubes from different brands of air sampling pumps?? It is not recommended. How do I store and dispose of the tubes?? As detector tubes contain sensitive reagents that are ready to react, and some reagents might be corrosive, care should be taken for their storage and disposal. Used or date-expired detector tubes should be disposed properly following your local regulations. For further information, consult your detector tube representative. To keep the high quality of detector tubes, it is necessary to store them in a cool (0 to 10C) dark place (never expose them to the direct sunlight). Never store tubes above normal room temperature. What should I do when a tube breaks and my hands touched the chemical powder reagent? inside the tube?? Always immediately wash your hands, and never rub your eyes or touch your mouth before doing this. What is the shelf life of the Gastec detector tubes?? Detector tubes have up to a 3-year shelf life (depending on the reagent, if refrigerated). The use-by date is printed clearly on the front of the packet of the detector tubes. Please inform us at the point of purchase if you require a long shelf life. a1-class employs a stock rotation policy of first in, first out. Can I still use the tubes when their expiry date has been expired?? No, to avoid the risk of getting unreliable measurements, we definitely discourage the use of expired tubes. What is included with the purchase of a Gastec detector tube system?? The Gastec pump kit includes a protective carry case, a Gastec pump, an instruction manual and replacement filters. Detector tube packs include an instruction sheet and numbered stickers. Pack details display Batch number, number of tubes included and valid until date. What are the dimensions of the box? 150mm x 55mm x 20mm Feefo ReviewsSku: 1723939442-1588
10m Synthetic Rubber Sampling Hose for use with Gastec Systems
₦90,180.00Original price was: ₦90,180.00.₦75,150.00Current price is: ₦75,150.00.₦90,180.00Original price was: ₦90,180.00.₦75,150.00Current price is: ₦75,150.00. Add to basket Quick View -
SaleSI Analytics Titronics Range SI Analytics titrators range from the simple TITRONIC? 300 piston burette for simple dosing tasks and manual titration to the TitroLine? 7800 with sample changer TW alpha plus / TW 7400 and TitriSoft software for complex titration tasks. The devices are used in all areas of industry, such as the chemical, pharmaceutical and food industries, research, education, as well as water and environmental laboratories. All devices, as well as the software, provide convenience with innovative features as well as easy handling. Below is an overview of the range. Contact support@Allschoolabs.co.uk to assist with selecting the right titrator for your application. Simple piston burette TITRONIC? 300 for dosing tasks and manual titration Piston burette with exchangeable head TITRONIC? 500 for dosing tasks, manual titration and sample preparation Simple automatic titrator TitroLine? 5000 For total acidity in wine. Juices, chloride in food, FOS / TAC and more Automatic titrator with exchangeable head TitroLine? 7000 for all potentiometric and dead-stop titrations Karl Fischer Titrator TitroLine? 7500 KF for volumetric and TitroLine? 7500 KF trace for coulometric titrations Universal Titrator TitroLine? 7750 and TitroLine? 7750 KF for all types of potentiometric, vol. KF and dead-stop-titrations Universal titrator with IDS-technology TitroLine? 7800 for all potentiometric, vol. KF and dead-stop-titrations. Additionally with IDS-measuring input Sample changer for titration TW alpha plus for up to 24 and TW 7400 for up to 72 samples Feefo Reviews Product Attachments SI Analytics Titration Selection (601.78 kB) SI Analytics Titronic Range (1.51 MB)Sku: 1723938004-1333
10ml Dosing Unit For Titronic 110 TA 10 PLUS
₦527,155.00Original price was: ₦527,155.00.₦439,295.00Current price is: ₦439,295.00.₦527,155.00Original price was: ₦527,155.00.₦439,295.00Current price is: ₦439,295.00. Add to basket Quick View -
SaleGooch CruciblesIdeal for drying precipitates to constant mass at 110?CAlso suitable for ignition work up to 450?C (see safety notice)With integral glass sintered discManufactured from chemically resistant Pyrex? borosilicate glassThe labelling P1, P2, P3 etc refers to the porosity of the sintered disc in the base of the crucible;P1 = pore index 100 to 160 microns, ISO 4793 designation P160 - coarse precipitate filtration, gas dispersion, coarse grain material filtrationP2 = pore index 40 to 100 microns, ISO 4793 designation P100, medium and crystalline preciptate filtration, medium filtration and washing of gasesP3 = pore index 16 to 40 microns, ISO 4793 designation P40 - analytical work with medium precipitatesP4 = pore index 10 to 16 microns, ISO 4793 designation P16 - analytical work with fine precipitatesP5 = pore index 4 to 10 microns, ISO 4793 designation P10 - principally used for bacterial filtrationSafety Notice:Avoid sudden changes in temperature which can result in thermal breakage.For high temperature ignition work, use a furnace and slowly heat to 450?C maximum.Allow to cool to below 200?C before removing from the furnace. Feefo Reviews More Information More Information MaterialBorosilicate glassSku: 1723935439-906
10ml Gooch Crucible P3 20mm Dia Disc Pack of 20
₦203,090.00Original price was: ₦203,090.00.₦169,240.00Current price is: ₦169,240.00.₦203,090.00Original price was: ₦203,090.00.₦169,240.00Current price is: ₦169,240.00. Add to basket Quick View -
SaleSTERILIN INDIVIDUALLY FILM WRAPPED PLUGGED PIPETTESGamma irradiated to ensure sterility and certified non-pyrogenic with an endotoxin level of below 0.25EU/ml Batch specific certificate supplied in each carton Lot number for complete traceability Accuracy of ± 1% for nominal volume Clear black printed graduations for maximum clarity Descending and ascending graduations to aid pipetting Negative graduations for extra capacity Colour coded for ease of identification Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews More Information More Information Supplied asIndividually wrapped MaterialPolystyrene (PS) Sterile?YesSku: 1723965131-214
10ml Pipette with suction adaptor single wrap narrow orifice PS Irradiated
₦92,410.00Original price was: ₦92,410.00.₦77,010.00Current price is: ₦77,010.00.₦92,410.00Original price was: ₦92,410.00.₦77,010.00Current price is: ₦77,010.00. Add to basket Quick View -
SaleDesigned for sample collection and transport where sample security and integrity is key. The tamper evident cap provides proof that the sample has not been opened before.Leak proof cap with unique security seal to assure sample security.Conical design with free standing baseMoulded graduations in 1mL steps.Made of high clarity polypropylene.Caps available in white, blue and pink for easy sample identificationTemperature range -90?C to 121?CChoice of 5 or 10ml and with a range of coloured caps for sample identification Feefo Reviews Related Blogs How can I keep my samples secure and tamper proof? The first stage of any test is to collect a sample. Whether it's water, biological tissues, or a sample from a production line, it must be representative of the bulk and not be altered in order to give accurate results. Most samples will have to be transported after they are collected - this might be just a few meters from a production line to the test room, or could be a lengthy transit fr...9 years ago More Information More Information Autoclavable?Yes ColourBlue MaterialPolypropylene (PP) Volume (ml)10Sku: 1723851535-10
10ml Polypropylene Tube with Blue Tamper Evident Cap Pack of 250
₦31,915.00Original price was: ₦31,915.00.₦26,595.00Current price is: ₦26,595.00.₦31,915.00Original price was: ₦31,915.00.₦26,595.00Current price is: ₦26,595.00. Add to basket Quick View -
SaleDesigned for sample collection and transport where sample security and integrity is key. The tamper evident cap provides proof that the sample has not been opened before.Leak proof cap with unique security seal to assure sample security.Conical design with free standing baseMoulded graduations in 1mL steps.Made of high clarity polypropylene.Caps available in white, blue and pink for easy sample identificationTemperature range -90?C to 121?CChoice of 5 or 10ml and with a range of coloured caps for sample identification Feefo Reviews Related Blogs How can I keep my samples secure and tamper proof? The first stage of any test is to collect a sample. Whether it's water, biological tissues, or a sample from a production line, it must be representative of the bulk and not be altered in order to give accurate results. Most samples will have to be transported after they are collected - this might be just a few meters from a production line to the test room, or could be a lengthy transit fr...9 years ago More Information More Information Autoclavable?Yes ColourClear MaterialPolypropylene (PP) Volume (ml)10Sku: 1723942006-2023
10ml Polypropylene Tube with Pink Tamper Evident Cap Pack of 250
₦31,915.00Original price was: ₦31,915.00.₦26,595.00Current price is: ₦26,595.00.₦31,915.00Original price was: ₦31,915.00.₦26,595.00Current price is: ₦26,595.00. Add to basket Quick View -
SaleDesigned for sample collection and transport where sample security and integrity is key. The tamper evident cap provides proof that the sample has not been opened before.Leak proof cap with unique security seal to assure sample security.Conical design with free standing baseMoulded graduations in 1mL steps.Made of high clarity polypropylene.Caps available in white, blue and pink for easy sample identificationTemperature range -90?C to 121?CChoice of 5 or 10ml and with a range of coloured caps for sample identification Feefo Reviews Related Blogs How can I keep my samples secure and tamper proof? The first stage of any test is to collect a sample. Whether it's water, biological tissues, or a sample from a production line, it must be representative of the bulk and not be altered in order to give accurate results. Most samples will have to be transported after they are collected - this might be just a few meters from a production line to the test room, or could be a lengthy transit fr...9 years ago More Information More Information Autoclavable?Yes ColourWhite MaterialPolypropylene (PP) Volume (ml)10Sku: 1723940628-1800
10ml Polypropylene Tube with White Tamper Evident Cap Pack of 250
₦31,915.00Original price was: ₦31,915.00.₦26,595.00Current price is: ₦26,595.00.₦31,915.00Original price was: ₦31,915.00.₦26,595.00Current price is: ₦26,595.00. Add to basket Quick View -
Sale6 replacement 10ml, 1" round sample vials with cap suitable for the DR700 & DR800 series, Mark I & II colorimeters Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Feefo Reviews Related Blogs What vials and sample cells are compatible with my Hach DR1900? The DR1900 by Hach is a portable spectrophotometer with over 220 pre-programmed test methods, accepting the Hach and the Lange chemistry. It is rugged and has a large, clear screen, with easy to use navigation, making it great for use in the field. [caption id="attachment_15657" align="aligncenter" width="300"] The DR1900 portable spectrophotometer[/caption] The DR1900 will accept the followi...4 years ago What vials and sample cells are compatible with my Hach DR900? The DR900 by Hach is a robust, portable colorimeter, capable of performing many dozens of different tests, supporting the Hach chemistry type. It can accept a number of different sizes cuvettes/samples cells ? 1 inch round sample cells 1cm sample cells 16mm COD/TNT vials [caption id="attachment_15641" align="aligncenter" width="300"] Hach DR900 colorimeter[/caption] Every Hach method c...4 years ago What vials and sample cells are compatible with my Hach DR300? The DR300 by Hach is a robust, portable single parameter colorimeter. It is the follow on from the Pocket colorimeter II which has been discontinued for most parameters - offering improved waterproofing, a large display and ergonomic design combined with optional Bluetooth and system integration. This unit is available in two formats ? a single wavelength (either 500, 528, 600, 655nm) or pre-pr...4 years ago Hach Sample Cells - Explained Hach have a wide variety of sample cells for use in their colorimeters and spectrophotometers. The correct type of sample cell that is required for every method programme with each compatible instrument will be detailed at the start of the method sheet. Here, any adapters that may be required along with any extra equipment needed to perform the test will also be listed. This is the typical form...5 years ago What are the replacement sample cells for Hach Pocket Colorimeter II? Replacement cells for the Hach pocket II colorimeter HH/24276-06 1133350 6 replacement sample vials with cap suitable for the Hach DR800 series and Hach Mark II pocket colorimeters15 years agoSku: 1723937947-1321
10ml Round Glass Sample Cell with Cap for Hach Colorimeter Pack of 6
₦54,420.00Original price was: ₦54,420.00.₦45,350.00Current price is: ₦45,350.00.₦54,420.00Original price was: ₦54,420.00.₦45,350.00Current price is: ₦45,350.00. Add to basket Quick View