General Information
Extended Product Type:
UA95-30-00-80
Product ID:
1SFL431022R8000
EAN:
7320500144572
Catalog Description:
UA95-30-00 220-230V 50Hz / 230-240V 60Hz Contactor
Long Description:
A 3-phase Contactor suitable for Capacitor switching application. Maximum permissible peak current 30 times the nominal RMS current. Operated with a control voltage, versions from 24…….690 V
Dimensions
Product Net Width:
90?mm
Product Net Depth / Length:
123.5?mm
Product Net Height:
148?mm
Product Net Weight:
1.8?kg
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Rated Operational Voltage:
Main Circuit 1000 V
Rated Frequency (f):
Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ?C 145 A
Rated Operational Power AC-3 (Pe):
(380 / 400 V) 45 kW
Rated Operational Power AC-6b (Pe):
(230 / 240 V) 40 ?C, 50 / 60 Hz 35 kvar
(230 / 240 V) 55 ?C, 50 / 60 Hz 35 kvar
(230 / 240 V) 70 ?C, 50 / 60 Hz 30 kvar
(400 / 415 V) 40 ?C, 50 / 60 Hz 65 kvar
(400 / 415 V) 70 ?C, 50 / 60 Hz 55 kvar
(400 / 415 V) 55 ?C, 50 / 60 Hz 65 kvar
(440 V) 40 ?C, 50 / 60 Hz 65 kvar
(440 V) 55 ?C, 50 / 60 Hz 65 kvar
(440 V) 70 ?C, 50 / 60 Hz 55 kvar
(500 / 550 V), 40 ?C, 50 / 60 Hz 70 kvar
(500 / 550 V) 55 ?C, 50 / 60 Hz 70 kvar
(500 / 550 V) 70 ?C, 50 / 60 Hz 60 kvar
(690 V) 40 ?C, 50 / 60 Hz 80 kvar
(690 V) 55 ?C, 50 / 60 Hz 80 kvar
(690 V) 70 ?C, 50 / 60 Hz 70 kvar
Rated Short-time Withstand Current (Icw):
at 40 ?C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency:
240 cycles per hour
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Mechanical Durability:
10 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ? 1.1 x Uc Max. (at ? ? 70 ?C)
Rated Control Circuit Voltage (Uc):
50 Hz 220 ? 230 V
60 Hz 230 ? 240 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V?A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V?A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V?A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V?A
Operate Time:
Between Coil De-energization and NC Contact Closing 7 ? 15 ms
Between Coil Energization and NO Contact Closing 10 ? 25 ms
Connecting Capacity Main Circuit:
Bar 30 mm?
Flexible with Cable End 2 x 6 ? 35 mm?
Rigid 1 x 10 ? 95 mm?
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ? 2.5 mm?
Flexible with Insulated Ferrule 2x 0.75 ? 2.5 mm?
Flexible 2?0.75 ? 2.5 mm?
Solid 2 x 1 ? 4 mm?
Stranded 1 x 1 ?. 4 mm?
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles:
M8 hexagon socket screw with single connector
Terminal Type:
Cable Clamp
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V