General Information
Extended Product Type:
UA110-30-00RA-80
Product ID:
1SFL451024R8000
EAN:
7320500260524
Catalog Description:
UA110-30-00RA 220-230V 50Hz Contactor
Long Description:
A 3-phase Contactor suitable for Capacitor switching application. Maximum permissible peak current 100 times the nominal RMS current. Operated with a control voltage, versions from 24…….690 V
Categories
Products ? Low Voltage Products and Systems ? Control Products ? Contactors ? Block Contactors ? UA and UA..RA Contactors
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
0
Number of Auxiliary Contacts NC:
0
Rated Operational Voltage:
Main Circuit 1000 V
Rated Frequency (f):
Main Circuit 50 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ?C 160 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 ?C 160
(690 V) 55 ?C 145
(690 V) 60 ?C 145 A
(690 V) 70 ?C 130
Rated Operational Current AC-3 (Ie):
(415 V) 55 ?C 110 A
(440 V) 55 ?C 100 A
(500 V) 55 ?C 100 A
(690 V) 55 ?C 82 A
(1000 V) 55 ?C 30 A
(380 / 400 V) 55 ?C 110 A
(220 / 230 / 240 V) 55 ?C 110
Rated Operational Power AC-6b (Pe):
(230 / 240 V) 40 ?C, 50 / 60 Hz 45 kvar
(230 / 240 V) 55 ?C, 50 / 60 Hz 40 kvar
(230 / 240 V) 70 ?C, 50 / 60 Hz 35 kvar
(400 / 415 V) 40 ?C, 50 / 60 Hz 80 kvar
(400 / 415 V) 70 ?C, 50 / 60 Hz 60 kvar
(400 / 415 V) 55 ?C, 50 / 60 Hz 70 kvar
(440 V) 40 ?C, 50 / 60 Hz 85 kvar
(440 V) 55 ?C, 50 / 60 Hz 75 kvar
(440 V) 70 ?C, 50 / 60 Hz 70 kvar
(500 / 550 V), 40 ?C, 50 / 60 Hz 95 kvar
(500 / 550 V) 55 ?C, 50 / 60 Hz 82 kvar
(500 / 550 V) 70 ?C, 50 / 60 Hz 78 kvar
(690 V) 40 ?C, 50 / 60 Hz 130 kvar
(690 V) 55 ?C, 50 / 60 Hz 110 kvar
(690 V) 70 ?C, 50 / 60 Hz 100 kvar
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Mechanical Durability:
10 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ? 1.1 x Uc Max. (at ? ? 70 ?C)
Rated Control Circuit Voltage (Uc):
50 Hz 220 ? 230 V
60 Hz 230 ? 240 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V?A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V?A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V?A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V?A
Operate Time:
Between Coil De-energization and NC Contact Closing 7 ? 15 ms
Between Coil Energization and NO Contact Closing 10 ? 25 ms
Connecting Capacity Main Circuit:
Bar 30 mm?
Flexible with Cable End 1 x 10 ? 70 mm?
Rigid 2 x 6 ? 65 mm?
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ? 2.5 mm?
Flexible with Insulated Ferrule 2x 0.75 ? 2.5 mm?
Flexible 2?0.75 ? 2.5 mm?
Solid 2 x 1 ? 4 mm?
Stranded 1 x 1 ?. 4 mm?
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting Terminals (delivered in open position) Main Poles:
M8 hexagon socket screw with single connector
Terminal Type:
Cable Clamp
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
Reviews
There are no reviews yet.