YES! We deliver orders to 2184 cities worldwide →
See your region

1SFL467001R1311 AF146-30-11-13 Contactor

Sku: 1SFL467001R1311

Estimated Delivery Date: International: 2-3 days (by DHL Express)

See Recent Deliveries to your City Here

-2%

1SFL467001R1311 AF146-30-11-13 Contactor

Sku: 1SFL467001R1311

104,664.00 Save:2,400.00(2%)

Quantity:

Available in stock

Express delivery on this item

380000+ Products Online

100% Money Back

Description

General Information

Extended Product Type:
AF146-30-11-13

Product ID:
1SFL467001R1311

EAN:
7320500476994

Catalog Description:
AF146-30-11-13 Contactor

Long Description:
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, 50/60 Hz and DC

Categories

Products ? Low Voltage Products and Systems ? Control Products ? Contactors ? Block Contactors

Technical

Number of Main Contacts NO:
3

Number of Main Contacts NC:
0

Number of Auxiliary Contacts NO:
1

Number of Auxiliary Contacts NC:
1

Rated Operational Voltage:
Main Circuit 1000 V

Rated Frequency (f):
Main Circuit 50/60 Hz

Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ?C 225 A

Rated Operational Current AC-1 (Ie):
(1000 V) 40 ?C 225 A

(1000 V) 55 ?C 200 A

(1000 V) 60 ?C 200 A

(1000 V) 70 ?C 175 A

(690 V) 40 ?C 225

(690 V) 55 ?C 200

(690 V) 60 ?C 200 A

(690 V) 70 ?C 175

Rated Operational Current AC-3 (Ie):
(415 V) 55 ?C 146 A

(440 V) 55 ?C 146 A

(500 V) 55 ?C 130 A

(690 V) 55 ?C 93 A

(1000 V) 55 ?C 60 A

(380 / 400 V) 55 ?C 146 A

(220 / 230 / 240 V) 55 ?C 146

Rated Operational Power AC-3 (Pe):
(415 V) 75 kW

(440 V) 90 kW

(500 V) 90 kW

(690 V) 90 kW

(1000 V) 75 kW

(380 / 400 V) 75 kW

(220 / 230 / 240 V) 45 kW

Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3

Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3

Short-Circuit Protective Devices:
gG Type Fuses 315 A

Rated Short-time Withstand Current (Icw):
at 40 ?C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 15 min 200 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 min 477 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 30 s 674 A

Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A

Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour

(AC-2 / AC-4) 150 cycles per hour

(AC-3) 300 cycles per hour

Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V

acc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV

Mechanical Durability:
5 million

Maximum Mechanical Switching Frequency:
300 cycles per hour

Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ? 1.1 x Uc Max. (at ? ? 70 ?C)

Rated Control Circuit Voltage (Uc):
50 Hz 100 ? 250 V

60 Hz 100 ? 250 V

DC Operation 100 ? 250 V

Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V?A

Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V?A

Holding at Max. Rated Control Circuit Voltage DC 3 W

Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V?A

Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V?A

Pull-in at Max. Rated Control Circuit Voltage DC 135 W

Operate Time:
Between Coil De-energization and NO Contact Opening 37 ? 47 ms

Between Coil Energization and NO Contact Closing 25 ? 55 ms

Connecting Capacity Main Circuit:
Flexible 1 x 10 ? 70 mm?

Rigid Cu-Cable 1 x 10 ? 95 mm?

Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ? 2.5 mm?

Flexible with Insulated Ferrule 2x 0.75 ? 2.5 mm?

Flexible 2?0.75 ? 2.5 mm?

Solid 2 x 1 ? 4 mm?

Stranded 1 x 1 ?. 4 mm?

Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type:
Double Clamp

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 1000 V

General Use Rating UL/CSA:
(600 V AC) 200 A

Horsepower Rating UL/CSA:
(200 V AC) Three Phase 40 hp

(208 V AC) Three Phase 40 hp

(220 ? 240 V AC) Three Phase 50 hp

(440 ? 480 V AC) Three Phase 100 hp

(550 ? 600 V AC) Three Phase 125 hp

Reviews
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.

1SFL467001R1311 AF146-30-11-13 Contactor 104,664.00 Save:2,400.00(2%)
Home Shop Cart Account
Shopping Cart (0)

No products in the cart. No products in the cart.