General Information

Extended Product Type:
AF265-30-11-13

Product ID:
1SFL547002R1311

EAN:
7320500481189

Catalog Description:
AF265-30-11-13 Contactor

Long Description:
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, 50/60 Hz and DC

Categories

Products ? Low Voltage Products and Systems ? Control Products ? Contactors ? Block Contactors

Technical

Number of Main Contacts NO:
3

Number of Main Contacts NC:
0

Number of Auxiliary Contacts NO:
1

Number of Auxiliary Contacts NC:
1

Rated Operational Voltage:
Main Circuit 1000 V

Rated Frequency (f):
Main Circuit 50/60 Hz

Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ?C 400 A

Rated Operational Current AC-1 (Ie):
(1000 V) 40 ?C 350 A

(1000 V) 55 ?C 300 A

(1000 V) 60 ?C 300 A

(1000 V) 70 ?C 240 A

(690 V) 40 ?C 400

(690 V) 55 ?C 350

(690 V) 70 ?C 290

Rated Operational Current AC-3 (Ie):
(415 V) 55 ?C 265 A

(440 V) 55 ?C 265 A

(500 V) 55 ?C 250 A

(690 V) 55 ?C 250 A

(1000 V) 55 ?C 113 A

(380 / 400 V) 55 ?C 265 A

(220 / 230 / 240 V) 55 ?C 265

Rated Operational Power AC-3 (Pe):
(415 V) 132 kW

(440 V) 160 kW

(500 V) 160 kW

(690 V) 200 kW

(1000 V) 160 kW

(380 / 400 V) 132 kW

(220 / 230 / 240 V) 75 kW

Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3

Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3

Short-Circuit Protective Devices:
gG Type Fuses 500 A

Rated Short-time Withstand Current (Icw):
at 40 ?C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 15 min 400 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 min 865 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A

Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A

Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour

(AC-2 / AC-4) 150 cycles per hour

(AC-3) 300 cycles per hour

Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 ?C 350 A

(220 V) 3 Poles in Series, 40 ?C 350 A

Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 ?C 350 A

(220 V) 3 Poles in Series, 40 ?C 350 A

Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 ?C 350 A

(220 V) 3 Poles in Series, 40 ?C 350 A

Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V

acc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV

Mechanical Durability:
5 million

Maximum Mechanical Switching Frequency:
300 cycles per hour

Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ? 1.1 x Uc Max. (at ? ? 70 ?C)

Rated Control Circuit Voltage (Uc):
50 Hz 100 ? 250 V

60 Hz 100 ? 250 V

DC Operation 100 ? 250 V

Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V?A

Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V?A

Holding at Max. Rated Control Circuit Voltage DC 4.5 W

Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V?A

Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V?A

Pull-in at Max. Rated Control Circuit Voltage DC 410 W

Operate Time:
Between Coil De-energization and NO Contact Opening 37 ? 47 ms

Between Coil Energization and NO Contact Closing 25 ? 55 ms

Connecting Capacity Main Circuit:
Flexible 2 x 70 ? 185 mm?

Rigid Al-Cable 1 x 185 ? 240 mm?

Rigid Cu-Cable 2 x 70 ? 185 mm?

Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ? 2.5 mm?

Flexible with Insulated Ferrule 2x 0.75 ? 2.5 mm?

Flexible 2?0.75 ? 2.5 mm?

Solid 2 x 1 ? 4 mm?

Stranded 1 x 1 ?. 4 mm?

Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type:
Main Circuit: Bars

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 1000 V

General Use Rating UL/CSA:
(600 V AC) 350 A

Horsepower Rating UL/CSA:
(200 V AC) Three Phase 75 hp

(208 V AC) Three Phase 75 hp

(220 ? 240 V AC) Three Phase 100 hp

(440 ? 480 V AC) Three Phase 200 hp

(550 ? 600 V AC) Three Phase 250 hp

Reviews
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.

1SFL547002R1311 AF265-30-11-13 Contactor 224,352.00 Save:2,400.00(1%)
Home Shop 11 Cart Account
Shopping Cart (11)