General Information
Extended Product Type:
AF580-30-11-70
Product ID:
1SFL617001R7011
EAN:
7320500217696
Catalog Description:
AF580-30-11 100-250V 50/60Hz / 100-250V DC Contactor
Long Description:
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC
Categories
Products ? Low Voltage Products and Systems ? Control Products ? Contactors ? Block Contactors
Parts & Services ? Drives ? Low voltage AC drives ? Legacy AC drives ? MoCon
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
1
Rated Operational Voltage:
Main Circuit 1000 V
Rated Frequency (f):
Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ?C 800 A
Rated Operational Current AC-1 (Ie):
(1000 V) 40 ?C 800 A
(1000 V) 55 ?C 700 A
(1000 V) 70 ?C 580 A
(690 V) 40 ?C 800
(690 V) 55 ?C 700
(690 V) 70 ?C 580
Rated Operational Current AC-3 (Ie):
(415 V) 55 ?C 580 A
(440 V) 55 ?C 580 A
(500 V) 55 ?C 580 A
(690 V) 55 ?C 500 A
(1000 V) 55 ?C 250 A
(380 / 400 V) 55 ?C 580 A
(220 / 230 / 240 V) 55 ?C 580
Rated Operational Power AC-3 (Pe):
(415 V) 355 kW
(440 V) 355 kW
(500 V) 400 kW
(690 V) 500 kW
(1000 V) 355 kW
(380 / 400 V) 315 kW
(220 / 230 / 240 V) 160 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3
Short-Circuit Protective Devices:
gG Type Fuses 1000 A
Rated Short-time Withstand Current (Icw):
at 40 ?C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A
at 40 ?C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 6000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 5000 A
Maximum Electrical Switching Frequency:
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 60 cycles per hour
(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie):
(110 V) 1-Pole, 40 ?C 800 A
(110 V) 2 Poles in Series, 40 ?C 800 A
(220 V) 3 Poles in Series, 40 ?C 800 A
(600 V) 3 Poles in Series, 40 ?C 800 A
(850 V) 3 Poles in Series, 40 ?C 800 A
Rated Operational Current DC-3 (Ie):
(110 V) 1-Pole, 40 ?C 800 A
(110 V) 2 Poles in Series, 40 ?C 800 A
(220 V) 3 Poles in Series, 40 ?C 800 A
(600 V) 3 Poles in Series, 40 ?C 800 A
Rated Operational Current DC-5 (Ie):
(110 V) 1-Pole, 40 ?C 800 A
(110 V) 2 Poles in Series, 40 ?C 800 A
(220 V) 3 Poles in Series, 40 ?C 800 A
(600 V) 3 Poles in Series, 40 ?C 800 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Mechanical Durability:
3 million
Maximum Mechanical Switching Frequency:
300 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ? 1.1 x Uc Max. (at ? ? 70 ?C)
Rated Control Circuit Voltage (Uc):
50 Hz 100 ? 250 V
60 Hz 100 ? 250 V
DC Operation 100 ? 250 V
Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V?A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V?A
Holding at Max. Rated Control Circuit Voltage DC 5 V?A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V?A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V?A
Pull-in at Max. Rated Control Circuit Voltage DC 880 V?A
Operate Time:
Between Coil De-energization and NC Contact Closing 50 ? 70 ms
Between Coil De-energization and NO Contact Opening 53 ? 73 ms
Between Coil Energization and NC Contact Opening 45 ? 115 ms
Between Coil Energization and NO Contact Closing 50 ? 120 ms
Connecting Capacity Main Circuit:
Bar 52 mm?
Rigid Al-Cable 300 mm?
Rigid Cu-Cable 300 mm?
Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ? 2.5 mm?
Flexible with Insulated Ferrule 2x 0.75 ? 2.5 mm?
Flexible 2?0.75 ? 2.5 mm?
Solid 2 x 1 ? 4 mm?
Stranded 1 x 1 ?. 4 mm?
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Technical UL/CSA
Maximum Operating Voltage UL/CSA:
Main Circuit 1000 V
General Use Rating UL/CSA:
(600 V AC) 750 A
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 200 hp
(208 V AC) Three Phase 200 hp
(220 ? 240 V AC) Three Phase 250 hp
(440 ? 480 V AC) Three Phase 500 hp
(550 ? 600 V AC) Three Phase 600 hp
Reviews