YES! We deliver orders to 2184 cities worldwide →
See your region

1SFL677001R7011 AF1650-30-11 100-250V 50/60Hz / 100-250V DC Contactor

Sku: 1SFL677001R7011

Estimated Delivery Date: International: 2-3 days (by DHL Express)

See Recent Deliveries to your City Here

-0%

1SFL677001R7011 AF1650-30-11 100-250V 50/60Hz / 100-250V DC Contactor

Sku: 1SFL677001R7011

3,328,824.00 Save:12,000.00(0%)

Quantity:

Available in stock

Express delivery on this item

380000+ Products Online

100% Money Back

Description

General Information

Extended Product Type:
AF1650-30-11-70

Product ID:
1SFL677001R7011

EAN:
7320500249703

Catalog Description:
AF1650-30-11 100-250V 50/60Hz / 100-250V DC Contactor

Long Description:
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC

Categories

Products ? Low Voltage Products and Systems ? Control Products ? Contactors ? Block Contactors

Technical

Number of Main Contacts NO:
3

Number of Main Contacts NC:
0

Number of Auxiliary Contacts NO:
1

Number of Auxiliary Contacts NC:
1

Rated Operational Voltage:
Main Circuit 1000 V

Rated Frequency (f):
Main Circuit 50/60 Hz

Conventional Free-air Thermal Current (Ith):
acc. to IEC 60947-4-1, Open Contactors q = 40 ?C 1650 A

Rated Operational Current AC-1 (Ie):
(1000 V) 40 ?C 1650 A

(1000 V) 55 ?C 1450 A

(1000 V) 70 ?C 1270 A

(690 V) 40 ?C 1650

(690 V) 55 ?C 1450

(690 V) 70 ?C 1270

Rated Operational Current AC-3 (Ie):
(415 V) 55 ?C 1060 A

(440 V) 55 ?C 1060 A

(500 V) 55 ?C 970 A

(690 V) 55 ?C 970 A

(1000 V) 55 ?C 400 A

(380 / 400 V) 55 ?C 1060 A

(220 / 230 / 240 V) 55 ?C 1060

Rated Operational Power AC-3 (Pe):
(415 V) 630 kW

(440 V) 710 kW

(500 V) 710 kW

(690 V) 1000 kW

(1000 V) 600 kW

(380 / 400 V) 560 kW

(220 / 230 / 240 V) 315 kW

Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3

Rated Short-time Withstand Current (Icw):
at 40 ?C Ambient Temp, in Free Air, from a Cold State 10 s 10000 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 15 min 2200 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 min 5500 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 1 s 12000 A

at 40 ?C Ambient Temp, in Free Air, from a Cold State 30 s 7500 A

Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 12000 A

Maximum Electrical Switching Frequency:
(AC-1) 60 cycles per hour

(AC-2 / AC-4) 60 cycles per hour

(AC-3) 60 cycles per hour

Rated Operational Current DC-1 (Ie):
(220 V) 3 Poles in Series, 40 ?C 1650 A

(600 V) 3 Poles in Series, 40 ?C 1650 A

(850 V) 3 Poles in Series, 40 ?C 1650 A

Rated Operational Current DC-3 (Ie):
(220 V) 3 Poles in Series, 40 ?C 1650 A

(600 V) 3 Poles in Series, 40 ?C 1650 A

(850 V) 3 Poles in Series, 40 ?C 1650 A

Rated Operational Current DC-5 (Ie):
(220 V) 3 Poles in Series, 40 ?C 1650 A

(600 V) 3 Poles in Series, 40 ?C 1650 A

(850 V) 3 Poles in Series, 40 ?C 1650 A

Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V

acc. to UL/CSA 1000 V

Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV

Mechanical Durability:
0.5 million

Maximum Mechanical Switching Frequency:
300 cycles per hour

Coil Operating Limits:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ? 1.1 x Uc Max. (at ? ? 70 ?C)

Rated Control Circuit Voltage (Uc):
50 Hz 100 ? 250 V

60 Hz 100 ? 250 V

DC Operation 100 ? 250 V

Coil Consumption:
Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V?A

Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V?A

Holding at Max. Rated Control Circuit Voltage DC 20.5 V?A

Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V?A

Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V?A

Pull-in at Max. Rated Control Circuit Voltage DC 2290 V?A

Operate Time:
Between Coil De-energization and NC Contact Closing 35 ? 55 ms

Between Coil De-energization and NO Contact Opening 35 ? 55 ms

Between Coil Energization and NC Contact Opening 50 ? 80 ms

Between Coil Energization and NO Contact Closing 50 ? 80 ms

Connecting Capacity Main Circuit:
Bar 100 mm?

Connecting Capacity Auxiliary Circuit:
Flexible with Ferrule 2x 0.75 ? 2.5 mm?

Flexible with Insulated Ferrule 1x 0.75 ? 2.5 mm?

Flexible 2?0.75 ? 2.5 mm?

Solid 2 x 1 ? 4 mm?

Stranded 2 x 1 ?. 4 mm?

Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type:
Main Circuit: Bars

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
Main Circuit 1000 V

General Use Rating UL/CSA:
(1000 V AC) 1650 A

(600 V AC) 1650 A

Horsepower Rating UL/CSA:
(220 ? 240 V AC) Three Phase 450 hp

(440 ? 480 V AC) Three Phase 900 hp

(550 ? 600 V AC) Three Phase 1150 hp

Reviews
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.

1SFL677001R7011 AF1650-30-11 100-250V 50/60Hz / 100-250V DC Contactor 3,328,824.00 Save:12,000.00(0%)
Home Shop 30 Cart Account
Shopping Cart (30)