The?800??TS?Absorbance Reader is an affordable, high-quality microplate reader for assays in 6- to 384-well formats. The color touchscreen provides a visual user interface, making programming fast and intuitive. Applications for the? 800 TS extend from endpoint ELISA to temperature-sensitive kinetic assays, enabled with Gen5 Software. The 800 TS partners well with the 50? TS Washer, making a compact, versatile and affordable system to automate many application workflows.High quality, high performance at an affordable priceApplication versatility: ELISA, protein, and other endpoint assays to kinetics and cell-based assaysColor touchscreen for quick, easy programming and operationUSB flash drive for convenient data export, Gen5 import for analysisHigh precision and accuracy for quality resultsApplications
The?800?TS?easily measures absorbance in microplate-based assays. The onboard software is ideal for endpoint protocols, and under computer control with Gen5 software, applications include kinetic ELISA.ELISAProtein quantificationCytotoxicity assaysKineticsCell-based assaysThese are just a few examples of the many important applications for?800?TS.FeaturesHigh quality, high performance at an affordable price
The?800?TS?delivers high-quality, high-performance microplate reading at an affordable price. Robust instrument hardware and powerful software, along with unparalleled service and support, make?BioTek?the #1 plate reader brand.Application versatility: ELISA, protein, and other endpoint assays to kinetics and cell-based assays
With its?340 to 750 nm wavelength range, the?800?TS?is ideal for a variety of applications including ELISA, protein, and other endpoint protocols. Incubation and shaking expand the reach to enzyme kinetics and cell-based assays.Color touchscreen for quick, easy programming and operation
The touchscreen and menu-driven software make protocol creation intuitive and simple. Simple press start to ready, and the?800?TS?delivers results quickly and reliably. Protocols and results are saved onboard for instant recall.USB flash drive for convenient data export, Gen5 import for analysis
Many assays require more extensive data analysis and reporting. For convenience, you can export data to a USB flash drive and import it into Gen5 software for advanced data handling and custom reporting.High precision and accuracy for quality results
Although the?800?TS?is affordable, it doesn?t compromise performance. The high-quality hardware and optical design assure excellent results for all assays. It?s easy for your lab to verify and qualify performance over time, using the Absorbance Test Plate and Product Qualification Package.Specifications?GENERALDetection modesAbsorbanceRead methodsEndpoint. Kinetic, well area scanning (under computer control)Microplate types6-, 12-, 24-, 48-, 96-well microplates
384-well microplates, (NB configurations)
Maximum plate height 0.9″ (22.86 cm)Temperature control50 ?C (800TSI, 800TSUVI)ShakingLinear (except NB configurations)SoftwareGen5? Software for external computer control and data analysis (optional)Onboard softwareUp to 40 user-programmable protocols
Quick menu
Create, edit or run protocols
Save results to a USB thumb drivePrinterExternal USB printer (optional)User interface4.3″ color LCD touchscreen displayABSORBANCELight sourceTungsten halogenDetectorPhotodiodeWavelength selectionFiltersWavelength range400 to 750 nm
340 to 750 nm (“UV” configurations)Dynamic range0 to 4.0 OD (normal & rapid read modes)
0 to 3.0 OD (sweep read mode)Resolution0.001 OD (standalone mode)
0.0001 OD (via Gen5 control)Filter wheel capacity5Filters supplied405, 450, 490, 630
340, 405, 450, 490, 630 (“UV” configurations)OD accuracy96-well plate, normal read mode, 405 nm
+1.0% +0.010 OD from 0.0 to 2.0 ODOD linearity96-well plate, normal read mode, 405 nm
+1.0% from 0.0 to 2.0 OD
+3.0% from 2.0 OD to 3.0 ODOD repeatability96-well plate, normal read mode, 405 nm
+0.5%?+0.005 OD from 0.0 to 2.0 ODReading speed (kinetic)96 wells, single wavelength
Normal read mode: 30 seconds
Rapid read mode: 18 seconds
Sweep read mode: 11 seconds96 wells, dual-wavelength
Normal read mode: 63 secondsPHYSICAL CHARACTERISTICSConnectivity1) USB Type B for computer control
(2) USB Type-A for thumb drive and printerPowerExternal 24VDC power supply compatible with 100-240VAC @50-60Hz
Power consumption: 40 WattsDimensions16.5 x 15 x 7 inches
(41.9 x 38.1 x 17.8 cm)Weight18.5 lbs (8 kg)REGULATORYRegulatoryCE and TUV marked. IVD compliant.Specifications are subject to change. Performance values represent the average observed factory test values.Product More SpecificationsSpecification
?
GENERAL |
|
Detection modes | Absorbance |
Read methods | Endpoint. Kinetic, well area scanning (under computer control) |
Microplate types | 6-, 12-, 24-, 48-, 96-well microplates 384-well microplates, (NB configurations) Maximum plate height 0.9″ (22.86 cm) |
Temperature control | 50 ?C (800TSI, 800TSUVI) |
Shaking | Linear (except NB configurations) |
Software | Gen5? Software for external computer control and data analysis (optional) |
Onboard software | Up to 40 user-programmable protocols Quick menu Create, edit or run protocols Save results to a USB thumb drive |
Printer | External USB printer (optional) |
User interface | 4.3″ color LCD touchscreen display |
ABSORBANCE |
|
Light source | Tungsten halogen |
Detector | Photodiode |
Wavelength selection | Filters |
Wavelength range | 400 to 750 nm 340 to 750 nm (“UV” configurations) |
Dynamic range | 0 to 4.0 OD (normal & rapid read modes) 0 to 3.0 OD (sweep read mode) |
Resolution | 0.001 OD (standalone mode) 0.0001 OD (via Gen5 control) |
Filter wheel capacity | 5 |
Filters supplied | 405, 450, 490, 630 340, 405, 450, 490, 630 (“UV” configurations) |
OD accuracy | 96-well plate, normal read mode, 405 nm +1.0% +0.010 OD from 0.0 to 2.0 OD |
OD linearity | 96-well plate, normal read mode, 405 nm +1.0% from 0.0 to 2.0 OD +3.0% from 2.0 OD to 3.0 OD |
OD repeatability | 96-well plate, normal read mode, 405 nm +0.5%?+0.005 OD from 0.0 to 2.0 OD |
Reading speed (kinetic) |
96 wells, single wavelength 96 wells, dual-wavelength |
PHYSICAL CHARACTERISTICS |
|
Connectivity | 1) USB Type B for computer control (2) USB Type-A for thumb drive and printer |
Power | External 24VDC power supply compatible with 100-240VAC @50-60Hz Power consumption: 40 Watts |
Dimensions | 16.5 x 15 x 7 inches (41.9 x 38.1 x 17.8 cm) |
Weight | 18.5 lbs (8 kg) |
REGULATORY | |
Regulatory | CE and TUV marked. IVD compliant. |
Specifications are subject to change. Performance values represent the average observed factory test values. |
?
Made InUSAWrite a review
Your Name
Your ReviewNote: HTML is not translated!
Rating
Bad
Good Captcha Please complete the captcha validation below
Continue
Reviews