Feature
1.????15-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR2.????13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;3.????Efficient resistance to interference of defibrillator and electrosurgical cautery;4.????SPO2 can testing for 0.1% Weak;5.????RA-LL impedance Respiration;6.????Trend Coexist Display;7.????OxyCRG DyNamic View Display;8.????Bed to Bed view Display;9.????Networking capacity and nurse calling system;10.??Options of printing, IBP, VGA and EtCO2;11.??UP to 4 hours working capacity of built-in rechargeable battery;12.??15.1″ high resolution color TFT LCD display;13.??Large volume of tabular and graphic trends information storage and easy to recall;14.??Anti-ESU, anti- defibrillator;15.??Capture dynamic waveforms.Technical SpecificationECGLead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)Lead selection: I, II, III, avR, avL, avF, V,Waveform: 2 chLead mode: 3 Leads (R, L, F or RA, LA, LL)Lead selection: I, II, III,Waveform: 1 chGain: ?2.5mm/mV, ?5.0mm/mV, ?10mm/mV, ?20mm/mV, autoHeart Rate and AlarmRangeAdult: 15 ~ 300 bpmNeo/Ped: 15 ~ 350 bpmAccuracy: ? 1% or ? 1bpm, which greatResolution: 1 bpmSensitivity: > 200 (uV P-P)Differential Input Impedance: > 5 M?CMRR-Monitor: > 105 dB-Operation: > 105 dB-Diagnosis: > 85 dBElectrode offset potential: ?300mVLeakage Current: < 10 uABaseline Recovery: < 3 S after Defi.ECG Signal Range: ?8 m V (Vp-p)Bandwidth??-Surgery: 1 ~ 15 Hz-Monitor: 0.5 ~ 35 Hz-Diagnostic: 0.05 ~ 100 HzCalibration Signal: 1 (mV p-p), Accuracy: ?5%?ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mVARR DetectingType: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNCAlarm: AvailableReview: AvailableRespirationMethod: Impedance between R-F (RA-LL)Differential Input Impedance: >2.5 M?Measuring Impedance Range: 0.3~5.0?Base line Impedance Range: 0 ? 2.5 K?Bandwidth: 0.3 ~ 2.5 HzResp. RateMeasuring and Alarm Range-Adult: 0 ~ 120 rpm-Neo/Ped: 0 ~ 150 rpmResolution: 1 rpmAccuracy: ?2 rpmApnea Alarm: 10 ~ 40 SNIBPMethod: OscillometricMode: Manual, Auto, STATMeasuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)Measuring Period in STAT Mode: 5 MinPulse Rate Range: 40 ~ 240 bpmAlarm Type: SYS, DIA, MEANMeasuring and alarm range??Adult Mode-SYS: 40 ~ 270 mmHg-DIA: 10 ~ 215 mmHg-MEAN: 20 ~ 235 mmHg??Pediatric Mode-SYS: 40 ~ 200 mmHg-DIA: 10 ~ 150 mmHg??-MEAN: 20 ~ 165 mmHgNeonatal Mode-SYS: 40 ~ 135 mmHg-DIA: 10 ~ 100 mmHg-MEAN: 20 ~ 110 mmHgResolution Pressure: 1mmHgAccuracy Pressure Maximum Mean error: ?5mmHgMaximum Standard deviation: ?8mmHgOverpressure Protection-Adult Mode: 297?3 mmHg-Pediatric Mode: 240?3 mmHg-Neonatal Mode: 147?3 mmHgSpO2Measuring Range: 0 ~ 100 %Alarm Range: 0 ~ 100 %Resolution: 1 %Accuracy: 70% ~ 100% ?2 %; 0% ~ 69% unspecifiedActualization interval: about 1 Sec.Alarm Delay: 10 Sec.Pulse RateMeasuring and Alarm Range: 20~300bpmResolution: 1bpmAccuracy: ?2bpmTemperatureChannel: 2Measuring and Alarm Range: 0 ~ 50 ?CResolution: 0.1?CAccuracy: ?0.1?CActualization interval: about 1 Sec.Average Time Constant:<10 Sec.IBP (Optional)Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and alarm range-ART: 0 ~ 300 mmHg-PA: -6 ~ 120 mmHg-CVP/RAP/LAP/ICP: -10 ~ 40 mmHg-P1/P2: -10 ~ 300 mmHgPress SensorSensitivity: 5 uV/V/mmHgImpedance: 300-3000?Resolution: 1 mmHgAccuracy: ?2% or ?1mmHg, which greatActualization interval: about 1 SecStandard Packing List5-lead ECG cable (including RESP)Adult finger SpO2 sensor???Adult NIBP cuff???NIBP extension tube?TEMP sensor?AC power adaptorECG electrodesOperation instructionSelectable AccessoryChild finger SPO2 sensorChild NIBP cuff?Neonate NIBP cuff
Reviews
There are no reviews yet.