Capacitance transformer magnetic current test of transformer CT analyzer testing equipment

Overview
Essential details
Warranty:
1 year
Customized support:
ODM, OBM, Software reengineering
Place of Origin:
Chongqing, China
Brand Name:
GOLD
Model Number:
GDVA-405
Power:
Electronic
Product name:
Capacitance transformer magnetic current test
Test standards:
IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5
Voltage output:
0.1~180V (AC)
Current output:
0.001~5A(RMS)
Power output:
500VA
Maximum knee voltage measurement:
45KV
PT phase angle test:
error < 9min
Memory capacity:
Temperature range:
-10℃~50℃; moist: ≤90%
Key words:
CT PT analyzer
Supply Ability
Supply Ability
200 Piece/Pieces per Month
Packaging & delivery
Packaging Details

Capacitance transformer magnetic current test of transformer omicron ct analyzer testing equipment
1.Wooden box with foam inside;
2.No fumigation,not influence the delivery;
3.Standard of IEC;
4.Customer OEM packing is also available;
5.Can be delivered by air,ship;
6.The products are packaged in paper or wood.
7.The package, logo and pattern can be customized.
If the order exceeds 1 piece, the weight of the goods will change . Please contact customer service.

Port

CHONGQING—Capacitance transformer magnetic current test of transformer omicron ct analyzer testing equipment

Picture Example:
Lead time:
Quantity(pieces) 1 – 1 >1
Lead time (days) 10 To be negotiated

Capacitance Transformer Magnetic Current Test Of

Transformer Omicron CT Analyzer Testing Equipment

Capacitance transformer magnetic current test of transformer CT analyzer testing equipment

Product Description

 

Product Description

The GDVA-402/404/405 CT/PT Analyzer is the revolutionary testing system for various CTs and PTs according to IEC60044-1/2/5/6 standard. The Analyzer can automatically complete the test within seconds by one click of the patented multifunctional rotary mouse. It allows to test the knee-point voltage up to 40kV CTs and PTs on-site in power grids or in manufacturers’ production facilities or test labs.

Features

1) Able to test Protection CTs, Measuring CTs, TP class CTs and inductive PTs

2) Test excitation characteristic and error curve based on low-frequency measurement principle

3) Measure ratio, polarity, ratio error and phase displacement error based on voltage method

4) Adopt patented multifunctional rotary mouse to replace the keypad

5) Adopt 5.7 inches LCD screen for display

6) Adopt DSP, ARM and embedded LINUX operation system

7) Both local test and PC remote test available

8) Higher measurement accuracy: 0.05 %

9) Print test results directly by built-in thermal printer

10) Small and light weight for easy transport

CT/PT Analyzer Technical Index

1) Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13

2) Power supply: AC220V±10%, 50/60Hz±10%

3) Voltage output: 0.1~180V (AC)

4) Current output: 0.001~5A(RMS)

5) Power output: 500VA

6) Maximum knee voltage measurement: 45KV

7) Current measurement:

    Range: 0~10A (automatically change range in 0.1/0.4/2/10A)

    Error: <±0.1%+0.01%FS

8) Voltage measurement:

     Range: 0~200V (automatically change range in 1V/10V/70V/200V) // Error: < ±0.1%+0.01%FS

9) Turns ratio measurement:

    Range:1~35000 / 1~2000 error<0.05% / 2000~5000  error<0.1% / 5000~35000  error<0.2%

 

10) Phase measurement: error: ±2min; resolution: 0.01min

11) Winding resistance measurement: 

      Range: 0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)

      Error: < 0.2%RDG+0.02%FS //    Maximum resolution: 0.1mΩ

12) Temperature measurement:-50~100 Celsius degree;  //  error<3 Celsius degree

13) CT Secondary burden: Range: 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)

      Error: <0.2%RDG+0.02%FS //      Maximum resolution: 0.001ohm

14)PT Secondary burden:

     Range: 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)

     Error :<0.2%RDG+0.02%FS // Maximum resolution: 0.1ohm

15)PT ratio measurement:Range: 1~35000 // 1~5000  error<0.2% // 5000~35000  error<0.5%16) PT phase angle test: error < 9min

17) Memory capacity: >1000 groups test results 

18)Working condition: temperature: -10~50; moist: ≤90%

19) Size: 485mm×356mm×183mm

20) Weight: <15kg

Main test function

CT (protection, measurement)

PT

Volt-ampere characteristic (excitation characteristic) curve

Volt-ampere characteristic (excitation characteristic) curve

Automatically give the inflection point value

Automatically give the inflection point value

Automatically give 5% and 10% error curves

Transformation ratio measurement

Transformation ratio measurement

Polarity judgment

Polarity judgment

Ratio measurement

One flow test

Angle difference measurement

Ratio measurement

AC withstand voltage test

Angle difference measurement

Secondary load test

AC withstand voltage test

Secondary winding test

Secondary load test

 Iron core demagnetization

Secondary winding test

 

Iron core demagnetization

 

Product Display 

Capacitance transformer magnetic current test of transformer CT analyzer testing equipmentCapacitance transformer magnetic current test of transformer CT analyzer testing equipmentCapacitance transformer magnetic current test of transformer CT analyzer testing equipmentCapacitance transformer magnetic current test of transformer CT analyzer testing equipment

Test Results 

Capacitance transformer magnetic current test of transformer CT analyzer testing equipmentCapacitance transformer magnetic current test of transformer CT analyzer testing equipment

 

Certifications

 Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd  has become a three-tier enterprise in safety production standardization, passed the ISO9001, quality management system certification, won the “high-tech enterprise” certificate,won the “high-tech products in Chongqing” certificate. The company’s output has hit new heights.So everyone can choose our products with confidence.

 

 

 

Contacts

 

Welcome to visit our website, welcome your inquiry.

 

Chongqing GOLD Mechanical & Electrical Equipment CO.,LTD.

Add:25F,Huarun Center,Xiejiang Street,Jiulongpo District,Chongqing,China,400050

Capacitance transformer magnetic current test of transformer CT analyzer testing equipment

Mobile:+8615922982462

Website:http://www.cqgoldequipment.com/

 

Capacitance transformer magnetic current test of transformer CT analyzer testing equipment 

Reviews
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.

Capacitance transformer magnetic current test of transformer CT analyzer testing equipment 3,040,989.60
Home Shop 1 Cart Account
Shopping Cart (1)