Essential details
Warranty:
1 year
Customized support:
OEM
Place of Origin:
Shandong, China
Brand Name:
Winner
Size Range:
0.1μm-2000μm|0.1μm-1200μm
Standard:
ISO13320-1:1999,GB/T19077.1-2008, Q/0100JWN001-2013
Channels Number:
100pcs/97pcs
Accuracy error:
<1%
Repeatability error:
<1%
Light Source:
He-Ne laser
Operation Mode:
Manual / one key test
Optical Path Calibration System:
manual
Weight:
58KG
Application:
Laboratory
Supply Ability
Supply Ability
30 Set/Sets per Month
Packaging & delivery
Packaging Details

The laser particle size analyzer package is plywood box.

Port

Qingdao/Hongkong

Picture Example:
Lead time:
Quantity(sets)1 – 2>2
Lead time (days)5To be negotiated
Video Description

00:00

00:28

Winner3008A/Winner3008B
Product Description
Winner3008A/B is intelligent dry laser particle size analyzer, manual and full automatic operation model. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy.
It use air as dispersion medium, and use turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It’s fit for any dry powder materials, especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It’s with the same accuracy and repeatability.

Main Features

1) Advanced testing optical path.
Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range.

2)Scientific dispersion system
Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion system’s working life.

3)Human-based operation mode Manual and Full automatic, easy choose.

4)High precision-automatic optical path calibration system
It’s composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.

5)Intelligent data analysis-winner unique software support
Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output.

6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(bigger than or less than a certain particle diameter).


7)Users can design the test report output and display forms according to industry requirements.
Specification
Model
Winner3008A/Winner3008B
Standard
ISO 13320-1:1999;GB/T19077.1-2308;Q/0100JWN001-2013
Measuring Range
0.1-2000μm/0.1-1200μm
Channels Number
100/97pcs
Accuracy
<1% (Deviation of D50 on national standard sample)
Repeatability
<1% (Deviation of D50 on national standard sample )
Light source
He-Ne laser (λ= 632.8nm, P>2.0MW)
Dispersion
Dry-turbulence dispersion mode, normal shock wave shear technique
Operation Mode
Manual & Full automatic
Operation temperature
+5°C to +40°C
Feeding
Automatic vibration feeding
Optical Calibration System
Automatic
Software function
Analysis mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
Statistic Method
Volume Distribution, Quantity Distribution
Statistic Comparison
Several Testing Results of samples
Different batches of samples testing result,
Samples before and after processing,
Test result of samples in different time.
User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries
Test Report
Word, Excel,Photo( Bmp), Text etc
Multiple language Support
Multiple language Support
Intelligent operation
Better Repeatability after remove human-factor
Test Speed
<1min for each time
Power supply
220V
Volume
L105cm×W44cm×H54cm
Net Weight
58Kg

Principle

Test Operation Interface:

Demo Test Report

Application

Winner3008 is widely used for cement, ceramic, medicine, dope, dye, padding, chemical products, catalyst, braize, dust, additive,pesticide, explosive, graphite, photosensitive material, fuel, metal and nonmetal powder, calcium carbonate, kaolin,coffee and other powder materials.
It has unique applicability and practicability, especially for those occurs chemical reactions, change shapes and loss in liquid, such as Chinese herbal medicine, magnetic materials and powder industry with wide distribution and large particle size.
Company Profile
Jinan Winner Particle Instrument Co., Ltd. have have been specialized in particle size analyzer for more than 30 years, since we undertake National Science Project-particle size analyzer development in 1985.
We are the 1st manufacturer to produce Nano-particle size analyzer in China.

Our particle size analyzer will enable you understand materials well, and save your time and cost. Reliable data enables scientists, researchers and engineers to evolve formulations and processes with confidence. Our products guide research and product development, manage and control manufacturing quality, and optimize output.

By now, We have Laser Particle size analyzer, Image particle size analyzer, Spray particle size analyzer, particles counter and Nano-particles size analyzer and so on.

We are dedicated to offer you the best particle size analysis solution.
Your satisfaction is our eternal target!

Certifications
Exhibition
Our Customers

Cooperative Partner

Our Team

Our goal is to provide super quality and competitive price laser particle size analyzer for clients all over the world!
We created more than 10 first particle size analysis technology in China!
Recommend Products

Quality Assurance


1. Strictly conforming to ISO9001-2000 quality management system.

2. Strict control from purchasing materials, process inspection to final particle size distribution test.

3. QC department to execute quality control regulations.
4.Only qualified components will be assembled and total laser particle size analyzer must be inspected completely before sale.
5.Laser particle size analyzer will be processed preventing -shake test before delivery.
After Sale Service


1.Operation demo video CD will be offered.

2. Offer free-training service.
3. The quality assurance date is 1 year since finishing payment, Technology support will be provided for life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
Packing & Delivery
Winner particle testing equipment is Wooden box package.


We would ship machine by DHL, FeDex, China express, by sea and by air.

FAQ

Purchase laser particle size analyzer need know points:

1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so need liquid dispersion particle size analyzer also. Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.

2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model will be preciser, no need to buy large range model.

3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use water, alochol or organic solvent as dispersion media.For dry dispersion model, just use compressed air as dispersion media.In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid model is better.

More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!
Reviews
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.