Products Description

30ATM Balloon Inflation Device
The disposable balloon inflation device is used in PTCA surgery together with balloon catheter. Expand the balloon by operating the balloon inflation device, thereby expand the blood vessel or implant stents inside the vessel.
Disposable balloon inflation device is sterilized by ethylene oxide, the shelf life is 3 years.
Product name:
|
Balloon inflation device
|
Type:
|
gun type
|
Model:
|
20ML 30 ATM
|
Package:
|
Blister package
|



Product Features
1. 20 ml clear syringe barrel with smooth moving plunger.
2. Pressure gauge dial with highlighted design and can read while contrast.
3. Self-locking mechanism for easy locking as well as gradual and rapid pressure release.
4. Grip Finger & Ergonomic handle for better grip.
5. Charging device has large range, up to 40ATM.
6. Precision manometer shows accurate pressure.
3. Self-locking mechanism for easy locking as well as gradual and rapid pressure release.
4. Grip Finger & Ergonomic handle for better grip.
5. Charging device has large range, up to 40ATM.
6. Precision manometer shows accurate pressure.
Recommend Products
Manufacturer picture



Instructions For Use
Preparing inflation device
1. Squeeze the locking lever to allow the plunger to move freeely.
2. Release the locking lever to allow the plunger to move by rotation (to fill the inflation device)
2. Release the locking lever to allow the plunger to move by rotation (to fill the inflation device)
Filling inflation device
1. Fill a tray with sterile water, saline,or contrast.
2. Turn on the three way stopcock.
3. Insert distal tip of inflation device.
4. Fill syringe by squeezing the locking lever and pulling back plunger completely, then releasing the locking lever.
5. Allow the syringe to fill until it stops.
6. After that push the air out of syringe by squeezing locking lever and pressing the plunger.
7. Then turn off the three way stopcock and release the locking lever.
8. Rotate the plunger to inflate the pressure until the lable reached the surgeon needed.
9. Release the pressure by squeezing the locking lever.
2. Turn on the three way stopcock.
3. Insert distal tip of inflation device.
4. Fill syringe by squeezing the locking lever and pulling back plunger completely, then releasing the locking lever.
5. Allow the syringe to fill until it stops.
6. After that push the air out of syringe by squeezing locking lever and pressing the plunger.
7. Then turn off the three way stopcock and release the locking lever.
8. Rotate the plunger to inflate the pressure until the lable reached the surgeon needed.
9. Release the pressure by squeezing the locking lever.
*The operation method is for reference purposes only the specific clinical recommendations shall prevail
CE and ISO13485

Q&A
Q&A
Q: Are you manufacturer or trading company?
A: We are manufacturer.
Q: Are you manufacturer or trading company?
A: We are manufacturer.
Q: Do you offer OEM service or customized products?
A: Yes.
Q: How many employees does your company have?
A: OVER 200.
Q: What is your manufacturing ability?
A: 200,000pcs each month
Q: What’s your best delivery time?
A: within 15 days.
Q: What’s your payment term for large order?
A: T/T, 30% down payment for order confirmation, and 70% payment before delivery.
Contact us

David Xu
Tianck Medical CO.,Ltd
Tel: +86 18122929357
Email: gw16@tianck.com
web: www.tianck.com
Address: Building C, No.16 Yinkui road, Kuichong town, Dapeng new district, Shenzhen, 518119 China
Tel: +86 18122929357
Email: gw16@tianck.com
web: www.tianck.com
Address: Building C, No.16 Yinkui road, Kuichong town, Dapeng new district, Shenzhen, 518119 China
Reviews
There are no reviews yet.