Customer matched zone "Lagos Delivery Options"
Sort by:
197729–197744 of 386543 Results
-
SaleFeatures Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration Adjustable?reference temperature and?temperature coefficient Adjustable cell constant and selectable measurement unit Automatic / manual temperature compensation and temperature calibration function Conductivity and total dissolved solids (TDS) conversion Four (4)?TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl Two (2) salinity calibration curves: NaCl, Seawater ?C & ?F temperature readings Auto log data; built-in memory can store up to 500?data? Auto stable, auto hold, and real-time measurement modes Auto shut-off (programmable: up to 30 minutes) Monochrome LCD with white LED backlight: 50 x 50 mm Powered?by 2 x AA batteries? Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip 3 years meter warranty Specifications Model LAQUA EC210 Conductivity/TDS/Res/Sal/Temp (?C/?F) Conductivity Range ...?S/cm to 200.0 mS/cm (k=1.0) Resolution 0.05% full scale Accuracy ?0.6% full scale; ?1.5% full scale > 18.0 mS/cm? Reference Temperature 15 to 30 ?C (adjustable) Temperature Coefficient 0.00 to 10.00% (adjustable) Cell Constant 0.1, 1.0, 10.0 (adjustable) Calibration Points Up to 4 (Auto) / Up to 5 (Manual) Measurement Unit S/cm, S/m (selectable / auto-ranging) TDS?Range ...ppm to 100 ppt (TDS factor=0.5) Resolution 0.01 ppm (mg/L) / 0.1 ppt (g/L) Accuracy ?0.1% full scale TDS Curves Linear (0.40 to 1.00), EN27888, 442, NaCl Resistivity Range 0.000 ??cm to 20.0 M??cm Resolution 0.05% full scale Accuracy ?0.6% full scale; ?1.5% full scale > 18.0 M??cm Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 % Resolution 0.1 ppt / 0.01% Accuracy ?0.2% full scale Salinity Curves NaCl / Seawater Calibration Option Yes Temperature Range -30.0 to 130.0 ?C / -22.0 to 266.0 ?F Resolution 0.1 ?C /??F? Accuracy ? 0.5 ?C / ? 0.9 ?C Calibration Option Yes Memory Data 500 Auto Log Data Yes Measurement Modes Auto Stable, Auto Hold, Real Time Auto Shut-Off Yes (Programmable: up to 30 minutes) Electrode Status Yes (On screen display) Diagnostic Messages Yes Meter Inputs BNC (for conductivity electrode), phono (for temperature sensor) Display Custom LCD with backlight Housing IP67, shock & scratch resistant, non-slip Power Requirement 2 x?AA batteries? Battery Life > 500 hours Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm Meter Weight? Approx. 260g (with batteries) / 216g (without batteries) Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) Horiba LAQUA 200 Series (1.57 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) Manual_LAQUA-EC210_EC220 (2.12 MB) LAQUA Range Brochure (24.74 MB) LAQUA 200 Videos The following videos will help you set up and use the 200 series meters: ? Measurement Mode? ? ? ? Calibration ? ? ? ? ? ? ? ? ? More Information More Information ColourWhiteSku: 1723836464-480
LAQUA EC210 (Meter only) Handheld Water Quality Meter
₦112,420.00Original price was: ₦112,420.00.₦93,685.00Current price is: ₦93,685.00.₦112,420.00Original price was: ₦112,420.00.₦93,685.00Current price is: ₦93,685.00. Add to basket Quick View -
SaleFeatures Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration Adjustable?reference temperature and?temperature coefficient Adjustable cell constant and selectable measurement unit Automatic / manual temperature compensation and temperature calibration function Conductivity and total dissolved solids (TDS) conversion Four (4)?TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl Two (2) salinity calibration curves: NaCl, Seawater ?C & ?F temperature readings With real-time clock and date/time stamp for GLP compliance Auto log data; built-in memory can store up to 1000?data Auto stable, auto hold, and real-time measurement modes Auto shut-off (programmable: up to 30 minutes) Monochrome LCD with white LED backlight: 50 x 50 mm Phono jack output for connecting the meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout? Powered?by 2 x AA batteries? Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip Packaged with electrode and calibration solutions in carrying case 3 years meter warranty Specifications Model LAQUA EC220 Conductivity/TDS/Res/Sal/Temp (?C/?F) Conductivity Range ...?S/cm to 200.0 mS/cm (k=1.0) Resolution 0.05% full scale Accuracy ?0.6% full scale; ?1.5% full scale > 18.0 mS/cm? Reference Temperature 15 to 30 ?C (adjustable) Temperature Coefficient 0.00 to 10.00% (adjustable) Cell Constant 0.1, 1.0, 10.0 (adjustable) Calibration Points Up to 4 (Auto) / Up to 5 (Manual) Measurement Unit S/cm, S/m (selectable / auto-ranging) TDS?Range ...ppm to 100 ppt (TDS factor=0.5) Resolution 0.01 ppm (mg/L) / 0.1 ppt (g/L) Accuracy ?0.1% full scale TDS Curves Linear (0.40 to 1.00), EN27888, 442, NaCl Resistivity Range 0.000 ??cm to 20.0 M??cm Resolution 0.05% full scale Accuracy ?0.6% full scale; ?1.5% full scale > 18.0 M??cm Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 % Resolution 0.1 ppt / 0.01% Accuracy ?0.2% full scale Salinity Curves NaCl / Seawater Calibration Option Yes Temperature Range -30.0 to 130.0 ?C / -22.0 to 266.0 ?F Resolution 0.1 ?C /??F? Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments Horiba LAQUA 200 Series (1.57 MB) HORIBA LAQUA Product Brochure (15.04 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) Manual_LAQUA-EC210_EC220 (2.12 MB) LAQUA Range Brochure (24.74 MB) More Information More Information ColourWhiteSku: 1723836936-498
LAQUA EC220 (Meter only) Handheld Water Quality Meter
₦183,965.00Original price was: ₦183,965.00.₦153,305.00Current price is: ₦153,305.00.₦183,965.00Original price was: ₦183,965.00.₦153,305.00Current price is: ₦153,305.00. Add to basket Quick View -
SaleCombination of the PH1500 and EC1500 PH1500 highly accurate pH and ORP measurements Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibration EC1500 for Conductivity, TDS, Salinity and Resistivity. Accepts up to 5 conductivity calibration points Automatic calibration at 84?S/cm, 1413?S/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applications Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request LAQUA 1500 Series Benchtop Meters This range comprises three benchtop models ideal for water quality measurements and design with these measurements in mind. All posses the same key features: Auto Shut Off - Set the meter to automatically shut off after up to 30 minutes. Large Memory - Store up to 1000 data set in the meter Auto Data Log - Automatically store data at intervals between 2 and 999 seconds. Data Transfer - Export data to a PC using a USB cable and free of charge software ? This range includes: LAQUA PH1500: pH - ORP - Temperature Highly accurate pH and ORP measurements ?Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibration Model Description PH1500 (3200891886) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual PH1500-SR (1300095720) PH1500 - above 9625-10D refillable, plastic body pH electrode pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) ? LAQUA EC1500: Conductivity - TDS - Resistivity - Salinity - Temperature Accepts up to 5 conductivity calibration points Automatic calibration at 84?S/cm, 1413?S/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applications Model Description EC1500 (3200899658) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual EC1500-S (1300095721) EC1500 - above 9382-10D plastic body conductivity cell k=1.0 Conductivity standard, 84?S, 1413?S, 12.88mS (1 x 250ml each) ? LAQUA PC1500: pH - ORP - Conductivity - TDS - Resistivity - Salinity - Temperature Measure pH and Conductivity at the same time Combination of the PH1500 and EC1500 Model Description PC1500 (3200899659) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual PC1500-SR (1300095722) ?PC1500 - above 9625-10D refillable, plastic body pH electrode 9382-10D plastic body conductivity cell k=1.0 pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) Conductivity standard, 84?S, 1413?S, 12.88mS (1 x 250ml each) ? Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Related Blogs How should I clean a pH electrode, or revive a damaged electrode? Traditional glass pH electrodes are very delicate and need regular care to keep them in good working order. If your electrode has been damaged by exposure to incompatible chemicals such as proteins, heavy metals or sulphides, you may be able to clean and revive it using specialized cleaning solutions... [caption id="attachment_7483" align="aligncenter" width="236"] pH electrodes need regu...Loading... Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) LAQUA Electrodes and Accessories (5.14 MB) LAQUA 1500 Series Benchtop Water Quality Meters (5.28 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) LAQUA Range Brochure (24.74 MB) More Information More Information ColourBlackSku: 1723806374-40
LAQUA PC1500 with electrode stand and power adaptor
₦262,720.00Original price was: ₦262,720.00.₦218,935.00Current price is: ₦218,935.00.₦262,720.00Original price was: ₦262,720.00.₦218,935.00Current price is: ₦218,935.00. Add to basket Quick View -
SaleThe 1500 Series meters include the following: PH1500 highly accurate pH and ORP measurements Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibration EC1500 for Conductivity, TDS, Salinity and Resistivity. Accepts up to 5 conductivity calibration points Automatic calibration at 84?S/cm, 1413?S/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applications PC1500 for pH, ORP, Conductivity, TDS, Salinity and Resistivity. Measure pH and Conductivity at the same time Combination of the PH1500 and EC1500 Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request LAQUA 1500 Series Benchtop Meters This range comprises three benchtop models ideal for water quality measurements and design with these measurements in mind. All posses the same key features: Auto Shut Off - Set the meter to automatically shut off after up to 30 minutes. Large Memory - Store up to 1000 data set in the meter Auto Data Log - Automatically store data at intervals between 2 and 999 seconds. Data Transfer - Export data to a PC using a USB cable and free of charge software ? This range includes: LAQUA PH1500: pH - ORP - Temperature Highly accurate pH and ORP measurements ?Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibration Model Description PH1500 (3200891886) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual PH1500-SR (1300095720) PH1500 - above 9625-10D refillable, plastic body pH electrode pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) ? LAQUA EC1500: Conductivity - TDS - Resistivity - Salinity - Temperature Accepts up to 5 conductivity calibration points Automatic calibration at 84?S/cm, 1413?S/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applications Model Description EC1500 (3200899658) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual EC1500-S (1300095721) EC1500 - above 9382-10D plastic body conductivity cell k=1.0 Conductivity standard, 84?S, 1413?S, 12.88mS (1 x 250ml each) ? LAQUA PC1500: pH - ORP - Conductivity - TDS - Resistivity - Salinity - Temperature Measure pH and Conductivity at the same time Combination of the PH1500 and EC1500 Model Description PC1500 (3200899659) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual PC1500-SR (1300095722) ?PC1500 - above 9625-10D refillable, plastic body pH electrode 9382-10D plastic body conductivity cell k=1.0 pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) Conductivity standard, 84?S, 1413?S, 12.88mS (1 x 250ml each) ? Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Related Blogs How should I clean a pH electrode, or revive a damaged electrode? Traditional glass pH electrodes are very delicate and need regular care to keep them in good working order. If your electrode has been damaged by exposure to incompatible chemicals such as proteins, heavy metals or sulphides, you may be able to clean and revive it using specialized cleaning solutions... [caption id="attachment_7483" align="aligncenter" width="236"] pH electrodes need regu...8 years ago Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) LAQUA Range Brochure (24.74 MB)Sku: 1723865471-1858
LAQUA PC1500-SR with refillable electrode stand and power adaptor
₦563,515.00Original price was: ₦563,515.00.₦469,595.00Current price is: ₦469,595.00.₦563,515.00Original price was: ₦563,515.00.₦469,595.00Current price is: ₦469,595.00. Add to basket Quick View -
SaleSpecifications Model LAQUA PC210 pH/ORP/Cond/TDS/Res/Sal/Temp (?C/?F) pH Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ? 0.01 pH Calibration Points Up to 5 (USA & NIST), Up to 6 (DIN) Buffer Options USA, NIST, DIN ORP Range ? 2000 mV Resolution 0.1 mV (< ?1000 mV), 1 mV (? ?1000 mV) Accuracy ? 0.3 mV?( 18.0 mS/cm? Reference Temperature 15 to 30 ?C (adjustable) Temperature Coefficient 0.00 to 10.00% (adjustable) Cell Constant 0.1, 1.0, 10.0 (adjustable) Calibration Points Up to 4 (Auto) / Up to 5 (Manual) Unit Setting S/cm, S/m (Auto-ranging) TDS Range ...ppm to 100 ppt (TDS factor=0.5) Resolution 0.01 ppm (mg/L) / 0.1 ppt (g/L) Accuracy ?0.1% full scale Calibration?Curves Linear (0.40 to 1.00), EN27888, 442, NaCl Resistivity Range 0.000 ??cm to 20.0 M??cm Resolution 0.05% full scale Accuracy ?0.6% full scale; ?1.5% full scale > 18.0 M??cm? Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 % Resolution 0.1 ppt / 0.01 % Accuracy ?0.2% full scale Calibration Curves NaCl, Seawater Calibration Option Yes Temperature Range -30.0 to 130.0 ?C / -22.0 to 266.0 ?F Resolution 0.1 ?C /??F Accuracy ? 0.5 ?C / ? 0.9 ?F Calibration Option Yes Memory Data 500 Auto Log Data Yes Measurement Modes Auto Stable, Auto Hold, Real Time Offset / Average Slope Display Yes? Calibration Alarm Yes (Programmable: up to 90 days) Auto Shut-Off Yes (Programmable: up to 30 minutes) Electrode Status Yes (On screen display) Diagnostic Messages Yes Meter Inputs 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors) Display Custom LCD with backlight Housing IP67, shock & scratch resistant, non-slip Power Requirement 2 x AA batteries Battery Life > 500 hours Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm Meter Weight Approx. 260g (with batteries) / 216g (without batteries)? Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) Horiba LAQUA 200 Series (1.57 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) Manual_LAQUA-PC210_PC220.pdf (2.66 MB) LAQUA Range Brochure (24.74 MB) LAQUA 200 Videos The following videos will help you set up and use the 200 series meters: ? Measurement Mode? ? ? ? Calibration ? ? ? ? ? ? ? ? ? More Information More Information ColourWhiteSku: 1723836649-486
LAQUA PC210 (Meter only) Handheld Water Quality Meter
₦212,825.00Original price was: ₦212,825.00.₦177,355.00Current price is: ₦177,355.00.₦212,825.00Original price was: ₦212,825.00.₦177,355.00Current price is: ₦177,355.00. Add to basket Quick View -
SaleSpecifications Model LAQUA PC220 pH/ORP/Cond/TDS/Res/Sal/Temp (?C/?F) pH Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ? 0.01 pH Calibration Points Up to 5 (USA & NIST), Up to 6 (DIN) Buffer Options USA, NIST, DIN ORP Range ? 2000 mV Resolution 0.1 mV (< ?1000 mV), 1 mV (? ?1000 mV) Accuracy ? 0.3 mV?( 18.0 mS/cm? Reference Temperature 15 to 30 ?C (adjustable) Temperature Coefficient 0.00 to 10.00% (adjustable) Cell Constant 0.1, 1.0, 10.0 (adjustable) Calibration Points Up to 4 (Auto) / Up to 5 (Manual) Unit Setting S/cm, S/m (Auto-ranging) TDS Range ...ppm to 100 ppt (TDS factor=0.5) Resolution 0.01 ppm (mg/L) / 0.1 ppt (g/L) Accuracy ?0.1% full scale Calibration?Curves Linear (0.40 to 1.00), EN27888, 442, NaCl Resistivity Range 0.000 ??cm to 20.0 M??cm Resolution 0.05% full scale Accuracy ?0.6% full scale; ?1.5% full scale > 18.0 M??cm? Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 % Resolution 0.1 ppt / 0.01 % Accuracy ?0.2% full scale Calibration Curves NaCl, Seawater Calibration Option Yes Temperature Range -30.0 to 130.0 ?C / -22.0 to 266.0 ?F Resolution 0.1 ?C /??F Accuracy ? 0.5 ?C / ? 0.9 ?F Calibration Option Yes Memory Data 1000 Auto Log Data Yes Real-time Clock Yes Date & Time Stamp Yes Measurement Modes Auto Stable, Auto Hold, Real Time Offset / Average Slope Display Yes? Calibration Alarm Yes (Programmable: up to 90 days) Auto Shut-Off Yes (Programmable: up to 30 minutes) Electrode Status Yes (On screen display) Diagnostic Messages Yes PC Communication Yes via PC (USB) cable PN 3200779639 Printer Communication Yes via Printer (RS232) cable PN 3200779638 Meter Inputs 2 x BNC (for pH and conductivity electrodes), 2 x phono (for temperature sensors) Meter Output phono (for PC/printer connection) Display Custom LCD with backlight Housing IP67, shock & scratch resistant, non-slip Power Requirement 2 x AA batteries Battery Life > 500 hours Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm Meter Weight Approx. 260g (with batteries) / 216g (without batteries)? Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments Horiba LAQUA 200 Series (1.57 MB) HORIBA LAQUA Product Brochure (15.04 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) Manual_LAQUA-PC210_PC220.pdf (2.66 MB) LAQUA Range Brochure (24.74 MB) LAQUA 200 Videos The following videos will help you set up and use the 200 series meters: ? Measurement Mode? ? ? ? Calibration ? ? ? ? ? ? ? ? ? More Information More Information ColourWhiteSku: 1723836762-493
LAQUA PC220 (Meter only) Handheld Water Quality Meter
₦259,115.00Original price was: ₦259,115.00.₦215,930.00Current price is: ₦215,930.00.₦259,115.00Original price was: ₦259,115.00.₦215,930.00Current price is: ₦215,930.00. Add to basket Quick View -
SaleSpecifications Model LAQUA PD210 pH/ORP/DO/Temperature (?C/?F) pH Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ? 0.01 pH Calibration Points Up to 5 (USA & NIST) / Up to 6 (DIN)? Buffer Options USA, NIST, DIN ORP Range ? 2000 mV Resolution 0.1 mV (<??1000 mV), 1 mV (???1000 mV) Accuracy ?0.3 mV?( 500 hours Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm Meter Weight Approx. 260g (with batteries) / 216g (without batteries) Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) Horiba LAQUA 200 Series (1.57 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) Manual_LAQUA-PD210_PD220 (2.42 MB) LAQUA Range Brochure (24.74 MB) LAQUA 200 Videos The following videos will help you set up and use the 200 series meters: ? Measurement Mode? ? ? ? Calibration ? ? ? ? ? ? ? ? ? More Information More Information ColourWhiteSku: 1723836916-497
LAQUA PD210 (Meter only) Handheld Water Quality Meter
₦212,825.00Original price was: ₦212,825.00.₦177,355.00Current price is: ₦177,355.00.₦212,825.00Original price was: ₦212,825.00.₦177,355.00Current price is: ₦177,355.00. Add to basket Quick View -
SaleSpecifications Model LAQUA PD220 pH/ORP/DO/Temperature (?C/?F) pH Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ? 0.01 pH Calibration Points Up to 5 (USA & NIST) / Up to 6 (DIN)? Buffer Options USA, NIST, DIN ORP Range ? 2000 mV Resolution 0.1 mV (<??1000 mV), 1 mV (???1000 mV) Accuracy ?0.3 mV?( 500 hours Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm Meter Weight Approx. 260g (with batteries) / 216g (without batteries) Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments Horiba LAQUA 200 Series (1.57 MB) HORIBA LAQUA Product Brochure (15.04 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) Manual_LAQUA-PD210_PD220 (2.42 MB) LAQUA Range Brochure (24.74 MB) LAQUA 200 Videos The following videos will help you set up and use the 200 series meters: ? Measurement Mode? ? ? ? Calibration ? ? ? ? ? ? ? ? ? More Information More Information ColourWhiteSku: 1723836635-485
LAQUA PD220 (Meter only) Handheld Water Quality Meter
₦259,115.00Original price was: ₦259,115.00.₦215,930.00Current price is: ₦215,930.00.₦259,115.00Original price was: ₦259,115.00.₦215,930.00Current price is: ₦215,930.00. Add to basket Quick View -
SalepH range: -2.00 to 16.00 pH Automatic pH calibration up to 5 points using USA or NIST buffers Switchable pH resolutions - 0.1, 0.01 pH ORP range: -2000 to +2000 mV Offset and slope display Automatic / Manual temperature compensation and temperature calibration function Auto-Hold / Auto-Stable measurement Built-in memory can store up to 1000 data sets Custom black and white static LCD USB / RS232 output 3 years meter warranty Specifications Model LAQUA PH1500 pH/ORP/Temperature (?C) pH Range -2.00 to 16.00 pH Resolution 0.1 / 0.01 pH Accuracy ? 0.01 pH Calibration Points Up to 5 Buffer Options USA / NIST ORP Range ??2000 mV Resolution 0.1 mV Accuracy ? 0.2 mV Temperature Range -30.0 to 130.0 ?C Resolution 0.1 ?C Accuracy ? 0.4 ?C Calibration Option Yes Memory Data 1000 Auto-Hold / Auto-Stable Yes Offset / Slope Display Yes (Independent acid and alkaline slopes depending on calibration) Electrode Status On screen display Diagnostic Messages Yes Display Custom black and white static LCD Inputs BNC, phono, DC sockets Output USB/RS232C Power Requirement AC?adaptor, 100-240V, 50/60Hz Weight Meter : 727g Set : 3700g Dimensions Meter : 155(L) x 150(D) x 67(H) mm Boxed : 410(L) x 260(D) x 230(H) mm Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request LAQUA 1500 Series Benchtop Meters This range comprises three benchtop models ideal for water quality measurements and design with these measurements in mind. All posses the same key features: Auto Shut Off - Set the meter to automatically shut off after up to 30 minutes. Large Memory - Store up to 1000 data set in the meter Auto Data Log - Automatically store data at intervals between 2 and 999 seconds. Data Transfer - Export data to a PC using a USB cable and free of charge software ? This range includes: LAQUA PH1500: pH - ORP - Temperature Highly accurate pH and ORP measurements ?Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibration Model Description PH1500 (3200891886) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual PH1500-SR (1300095720) PH1500 - above 9625-10D refillable, plastic body pH electrode pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) ? LAQUA EC1500: Conductivity - TDS - Resistivity - Salinity - Temperature Accepts up to 5 conductivity calibration points Automatic calibration at 84?S/cm, 1413?S/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applications Model Description EC1500 (3200899658) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual EC1500-S (1300095721) EC1500 - above 9382-10D plastic body conductivity cell k=1.0 Conductivity standard, 84?S, 1413?S, 12.88mS (1 x 250ml each) ? LAQUA PC1500: pH - ORP - Conductivity - TDS - Resistivity - Salinity - Temperature Measure pH and Conductivity at the same time Combination of the PH1500 and EC1500 Model Description PC1500 (3200899659) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual PC1500-SR (1300095722) ?PC1500 - above 9625-10D refillable, plastic body pH electrode 9382-10D plastic body conductivity cell k=1.0 pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) Conductivity standard, 84?S, 1413?S, 12.88mS (1 x 250ml each) ? Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Related Blogs How should I clean a pH electrode, or revive a damaged electrode? Traditional glass pH electrodes are very delicate and need regular care to keep them in good working order. If your electrode has been damaged by exposure to incompatible chemicals such as proteins, heavy metals or sulphides, you may be able to clean and revive it using specialized cleaning solutions... [caption id="attachment_7483" align="aligncenter" width="236"] pH electrodes need regu...8 years ago Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) LAQUA 1500 Series Benchtop Water Quality Meters (5.28 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) LAQUA Range Brochure (24.74 MB)Sku: 1723865540-1868
LAQUA PH1500 with electrode stand and power adaptor
₦168,635.00Original price was: ₦168,635.00.₦140,530.00Current price is: ₦140,530.00.₦168,635.00Original price was: ₦168,635.00.₦140,530.00Current price is: ₦140,530.00. Add to basket Quick View -
SaleThe 1500 Series meters include the following: PH1500 highly accurate pH and ORP measurements Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibration EC1500 for Conductivity, TDS, Salinity and Resistivity. Accepts up to 5 conductivity calibration points Automatic calibration at 84?S/cm, 1413?S/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applications PC1500 for pH, ORP, Conductivity, TDS, Salinity and Resistivity. Measure pH and Conductivity at the same time Combination of the PH1500 and EC1500 Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request LAQUA 1500 Series Benchtop Meters This range comprises three benchtop models ideal for water quality measurements and design with these measurements in mind. All posses the same key features: Auto Shut Off - Set the meter to automatically shut off after up to 30 minutes. Large Memory - Store up to 1000 data set in the meter Auto Data Log - Automatically store data at intervals between 2 and 999 seconds. Data Transfer - Export data to a PC using a USB cable and free of charge software ? This range includes: LAQUA PH1500: pH - ORP - Temperature Highly accurate pH and ORP measurements ?Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibration Model Description PH1500 (3200891886) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual PH1500-SR (1300095720) PH1500 - above 9625-10D refillable, plastic body pH electrode pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) ? LAQUA EC1500: Conductivity - TDS - Resistivity - Salinity - Temperature Accepts up to 5 conductivity calibration points Automatic calibration at 84?S/cm, 1413?S/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applications Model Description EC1500 (3200899658) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual EC1500-S (1300095721) EC1500 - above 9382-10D plastic body conductivity cell k=1.0 Conductivity standard, 84?S, 1413?S, 12.88mS (1 x 250ml each) ? LAQUA PC1500: pH - ORP - Conductivity - TDS - Resistivity - Salinity - Temperature Measure pH and Conductivity at the same time Combination of the PH1500 and EC1500 Model Description PC1500 (3200899659) Meter with integrated electrode stand Universal power adaptor with 6 plugs Instruction Manual PC1500-SR (1300095722) ?PC1500 - above 9625-10D refillable, plastic body pH electrode 9382-10D plastic body conductivity cell k=1.0 pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) Conductivity standard, 84?S, 1413?S, 12.88mS (1 x 250ml each) ? Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Related Blogs How should I clean a pH electrode, or revive a damaged electrode? Traditional glass pH electrodes are very delicate and need regular care to keep them in good working order. If your electrode has been damaged by exposure to incompatible chemicals such as proteins, heavy metals or sulphides, you may be able to clean and revive it using specialized cleaning solutions... [caption id="attachment_7483" align="aligncenter" width="236"] pH electrodes need regu...8 years ago Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) LAQUA Range Brochure (24.74 MB)Sku: 1723865465-1857
LAQUA PH1500-SR with refillable electrode stand and power adaptor
₦280,855.00Original price was: ₦280,855.00.₦234,045.00Current price is: ₦234,045.00.₦280,855.00Original price was: ₦280,855.00.₦234,045.00Current price is: ₦234,045.00. Add to basket Quick View -
SaleFeatures Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) 0.01 pH resolution Offset and average slope display? Automatic / manual temperature compensation and temperature calibration function ORP calibration option ?C & ?F temperature readings Auto log data; built-in memory?can store up to 500 data Auto shut-off (programmable: up to 30 minutes) Auto stable, auto hold, and real time measurement modes Calibration alarm (programmable: up to 90 days) Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mm Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip Powered?by?2 x AA batteries Packaged with electrode and calibration solutions in carrying case 3 years meter warranty Specifications Model LAQUA PH210 pH/ORP/Temperature (?C/?F) pH Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ? 0.01 pH Calibration Points Up to 5 (USA & NIST) / Up to 6 (DIN) Buffer Options USA, NIST, DIN ORP Range ? 2000 mV Resolution 0.1 mV (< ?1000 mV), 1 mV (? ?1000 mV) Accuracy ?0.3 mV ( 500 hours Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm Meter Weight Approx. 260 g (with batteries) / 216 g (without batteries) pH Meter & Electrode Selection Which pH meter/electrode do I need?... Making sure you have the right electrode and meter for your application can be confusing, not to mention correct maintenance and what to do if you are having issues. You can find links to our support guides below to help you through the process. If you are after an electrode selector guide for some of our most popular electrodes and what applications they are recommended for you can find that below. Electrode Selector Guide ? ? An introduction to pH pH, put simply is a measure of how acidic or basic a solution is. It is a measure of H+ions present.? pH can be measured in a number of ways including test strips, indicator solution or with a pH meter and electrode. If you want to read more about the pH and the pros and cons of these methods, you can check out our introduction guide here.? How to take a pH reading and care for your electrode pH electrodes require the correct storage and regular calibration. If you have a pH meter or are looking to purchase and need to find out more about the care and maintenance process then you can read our guide here. We also include a troubleshoot sections with the most reported issues and possible solutions.? Selecting the right electrode and meter for your application So you have decided you need to purchase a pH meter with electrode, but with such a wide selection out there, how do you know which is right for you? You can read our guide on the differences between electrodes and what applications different features are good for. We also have an electrode selection guide for some of our most popular electrodes.? Related Products pH Buffers Electrode Storage Solution Electrode Cleaning Solution ? ? If you require any further assistance, or extra information you can request that here and one of our trained technical specialists will be in contact. Please provide as much detail as possible so that we can get back to you with the right information. Request information Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) Horiba LAQUA 200 Series (1.57 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) Manual_LAQUA-PH210_PH220 (1.80 MB) LAQUA Range Brochure (24.74 MB) LAQUA 200 Videos The following videos will help you set up and use the 200 series meters: ? Measurement Mode? ? ? ? Calibration ? ? ? ? ? ? ? ? ? More Information More Information ColourWhiteSku: 1723836807-494
LAQUA PH210 (Meter only) Handheld Water Quality Meter
₦135,270.00Original price was: ₦135,270.00.₦112,725.00Current price is: ₦112,725.00.₦135,270.00Original price was: ₦135,270.00.₦112,725.00Current price is: ₦112,725.00. Add to basket Quick View -
SaleFeatures Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers) 0.01 pH resolution Offset and average slope display? Automatic / manual temperature compensation and temperature calibration function ORP calibration option ?C & ?F temperature readings With real-time clock and date/time stamp for GLP compliance Auto log data; built-in memory?can store up to 1000 data Auto shut-off (programmable: up to 30 minutes) Auto stable, auto hold, and real time measurement modes Calibration alarm (programmable: up to 90 days) Built-in electrode holder allows 2 electrodes to be attached Monochrome LCD with white LED backlight: 50 x 50 mm Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout? Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip Powered?by?2 x AA batteries Packaged with electrode and calibration solutions in carrying case 3 years meter warranty Specifications Model LAQUA PH220 pH/ORP/Temperature (?C/?F) pH Range -2.00 to 16.00 pH Resolution 0.01 pH Accuracy ? 0.01 pH Calibration Points Up to 5 (USA & NIST) / Up to 6 (DIN) Buffer Options USA, NIST, DIN ORP Range ? 2000 mV Resolution 0.1 mV (< ?1000 mV), 1 mV (? ?1000 mV) Accuracy ?0.3 mV ( 500 hours Meter Dimensions 160 (L) x 80 (W) x 40.60 (H) mm Meter Weight Approx. 260 g (with batteries) / 216 g (without batteries) pH Meter & Electrode Selection Which pH meter/electrode do I need?... Making sure you have the right electrode and meter for your application can be confusing, not to mention correct maintenance and what to do if you are having issues. You can find links to our support guides below to help you through the process. If you are after an electrode selector guide for some of our most popular electrodes and what applications they are recommended for you can find that below. Electrode Selector Guide ? ? An introduction to pH pH, put simply is a measure of how acidic or basic a solution is. It is a measure of H+ions present.? pH can be measured in a number of ways including test strips, indicator solution or with a pH meter and electrode. If you want to read more about the pH and the pros and cons of these methods, you can check out our introduction guide here.? How to take a pH reading and care for your electrode pH electrodes require the correct storage and regular calibration. If you have a pH meter or are looking to purchase and need to find out more about the care and maintenance process then you can read our guide here. We also include a troubleshoot sections with the most reported issues and possible solutions.? Selecting the right electrode and meter for your application So you have decided you need to purchase a pH meter with electrode, but with such a wide selection out there, how do you know which is right for you? You can read our guide on the differences between electrodes and what applications different features are good for. We also have an electrode selection guide for some of our most popular electrodes.? Related Products pH Buffers Electrode Storage Solution Electrode Cleaning Solution ? ? If you require any further assistance, or extra information you can request that here and one of our trained technical specialists will be in contact. Please provide as much detail as possible so that we can get back to you with the right information. Request information Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) Horiba LAQUA 200 Series (1.57 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) Manual_LAQUA-PH210_PH220 (1.80 MB) LAQUA Range Brochure (24.74 MB) More Information More Information ColourWhiteSku: 1723836948-499
LAQUA PH220 (Meter only) Handheld Water Quality Meter
₦195,990.00Original price was: ₦195,990.00.₦163,325.00Current price is: ₦163,325.00.₦195,990.00Original price was: ₦195,990.00.₦163,325.00Current price is: ₦163,325.00. Add to basket Quick View -
Features ?Control Unit ?Control Unit Design for Field Operations Auto-calibration feature provides hassle-free calibration of pH, dissolved oxygen, conductivity, turbidity and depth. Shock resistant cover designed for rough treatment in the field and is easily cleaned. Cable can be easily connected and disconnected with quick-connect fitting. ?Data Management Auto hold function freezes average data values on the screen to offer more time to verify or transcribe data. Diagnostic functions notify the user of errors. Integral USB connection for data transfer to a PC. Selectable measurement units allow the operator to report data without the need to convert data to desired units of measure. ?Sensor Probe Unit ?Multiple Sensors Housed in Each Probe Multiple sensors allow for the measurement of?11 parameters simultaneously?(pH, pH(mv), ORP, DO, COND, Salinity, TDS, Seawater Specific Gravity, Temperature, Turbidity, Water Depth). Turbidity sensor U-53 conforms to US EPA method 180.1. Precision has been improved over conventional instruments. The model U-53 high precision filed replaceable turbidity sensor with wiper has a resolution of 0.01 NTU. Turbidity sensor of U-54 conforms to EN ISO 7027. The model U-54 has a resolution of 0.01 NTU. Improved stability of the dissolved oxygen sensor has been achieved with a new 3 electrode design for fast response and polarographic sensor for ease of maintenance. pH and ORP electrodes can be replaced individually to reduce replacement costs Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Related Blogs Enhance Water Quality Monitoring with the LAQUA 300 Series Smart Handheld Meters 2 months ago Product Attachments LAQUA Multi Meters U-50 Series (3.76 MB) LAQUA Multi Meters U-50 Series Instruction Manual (2.36 MB) HORIBA LAQUA Product Brochure (15.04 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) LAQUA Range Brochure (24.74 MB) More Information More Information ColourWhiteSku: 1723836099-457
LAQUA U-50 Multi Meters Series
₦50,000.00 -
SaleLAQUA U-50 Multi Meters Series Accessories Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments HORIBA LAQUA Product Brochure (15.04 MB) LAQUA Electrodes and Accessories (5.14 MB) Automatic Temperature Compensation in pH Measurement (1.87 MB) LAQUA Range Brochure (24.74 MB) More Information More Information ColourWhiteSku: 1723835892-446
LAQUA U-50 Multi Meters Series Accessories
₦50,000.00Original price was: ₦50,000.00.₦44,090.00Current price is: ₦44,090.00.₦50,000.00Original price was: ₦50,000.00.₦44,090.00Current price is: ₦44,090.00. Add to basket Quick View -
SaleLAQUAtwin Measurements LAQUATWIN Three Step Measurement Follow simple, good testing procedures for accurate and dependable results: Calibrate correctly Avoid mixing samples and standards Always keep the sensor clean 1 Calibrate Always ensure the sensor is clean before calibrating. If not, clean thoroughly with water (don?t worry, LAQUAtwin meters are completely waterproof!). Place some standard solution on the sensor and press the calibration button. Once the smiley face appears, indicating that calibration is complete, wash off the standard solution with water and dry with a clean, soft tissue. 2 Test LAQUAtwin meters only need a tiny amount of sample - so no beaker is necessary. Fill the sensor with the sample and when the smiley face appears, the measurement is complete. 3 Clean Clean the sensor thoroughly with water, ready for the next test. When the sensor is nearing the end of its usable lifetime, it can be replaced; You don?t need to replace the meter. Sensors will need to be replaced after approx. 1500 measurements or when calibration cannot be completed. Sensors are sold separately and are easily removed and replaced. ? LAQUATwin One meter Six Different Methods Choose the best method according to your sample, your situation and your needs. Immersion: When you?re in the lab, you can test the sample in a beaker. Ensure the sensor guard sliding cap is open. Scoop: Use as a scoop to test water, for example from a river. Drops: LAQUAtwin meters can measure sample volumes as low as 0.05 mL. Place a drop of the sample onto the sensor with a pipette. Using the HORIBA sampling sheet, volumes down to 0.05 mL can be tested (except for conductivity measurements). Solid samples: Foods containing some moisture can be tested by placing a small piece directly onto the sensor. Powders: LAQUAtwin meters can also test dry powders. Simply place the powder sample onto the sensor, and drop on your defined volume of pure water. Paper and textiles: To test sheets of paper and textiles, cut up the sample into small pieces and place directly onto the sensor. Drop on your defined volume of pure water. LAQUAtwin sampling sheet. The sampling sheet allows trace volumes to be analysed. For example, you can even measure the pH of human skin by wiping with a sampling sheet soaked in pure water, and placing it on the sensor. Using the HORIBA sampling sheet, volumes down to 0.05 mL can be tested (except for conductivity measurements). Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Product Attachments Horiba LAQUAtwin Pocket Water Quality Meters (3.14 MB) HORIBA LAQUA Product Brochure (15.04 MB) LAQUAtwin Ion Sensor Maintenance Procedures (1.39 MB) LAQUAtwin pH Sensor Maintenance Procedures (1.44 MB) Soil Nitrate Measurement for Determination of Plant-AvailableNitrogen (1.98 MB) LAQUAtwin Conductivity Sensor Maintenance Procedures (1.34 MB) Soil Salinity Measurement in Almond Orchard (5.01 MB) Nitrate Measurement in Turf Grass (2.37 MB) Rapid In-Field Determination of Nitrogen in Onions (1.74 MB) LAQUAtwin Technical Tips (3.35 MB) LAQUA Range Brochure (24.74 MB) More Information More Information ColourWhiteSku: 1723853779-361
LAQUAtwin BOX – Storage box for LAQUAtwin meters, solutions and accessories
₦2,405.00Original price was: ₦2,405.00.₦2,005.00Current price is: ₦2,005.00.₦2,405.00Original price was: ₦2,405.00.₦2,005.00Current price is: ₦2,005.00. Add to basket Quick View -
SaleHypocalcemia?is one of the most common disorders affecting dairy cows at the onset of lactation. It is characterized by decrease in blood calcium below normal level. Stricken cows may have it with symptoms (clinical hypocalcemia or milk fever) or without symptoms (subclinical hypocalcemia). Ionized calcium (iCa) is the physiologically active form of calcium in blood. It reflects more accurately the current calcemic blood situation compared to total blood calcium as it equals the free available calcium ions. By measuring the ionized calcium levels of blood samples directly cow-side, the treatment of dairy cows can start sooner preventing debilitating symptoms or complications. The new LAQUAtwin Ca-11C has been specially developed for cow-side measurement of ionized calcium in blood. It is ideal for screening dairy cows for hypocalcemia.? Minimum sample volume: 0.3ml? Up to 2 calibration points Auto standard recognition: 1.25 & 2.50 mmol/L calcium ion? Auto hold / auto stable measurement Auto power off: 30 mins. Low battery indicator IP67 Rating dust & waterproof Replaceable sensor 150 hrs. battery life: continuous use without backlight Material: ABS epoxy Display: custom (monochrome) digital LCD with backlight Operating conditions: 5 to 40 ?C, 85% or less relative humidity Warranty: 2 years - meter, 6 months - sensor Packed in handy carrying case Supplied with 1.25 & 2.50 mmol/L calcium standards (25ml x 2 each), 251 cleaning solution (250ml) x 3, CR2032 batteries x 2, wash bottle, instruction and quick manuals Specifications Model LAQUAtwin Ca-11C Measurement Principle Ion Selective Electrode Minimum Sample Volume 0.3 ml Measurement?Range 0.1?5.0 mmol/L Resolution 0.1 mmol/L Accuracy ?20% of reading value Calibration Points 2 points ?1.25 mmol/L and 2.50 mmol/L? Display Custom (monochrome) digital LCD with backlight? Operating Temperature 5?to 40.0 ?C Operating Humidity 85% or less relative humidity (no condensation) Power CR2032 batteries (2) Material ABS epoxy Dimensions 164 x 29 x 20 mm (excluding projections) Mass Approx. 55 g?(including sensor?and batteries) Functions Auto Standard Recognition Auto Hold / Auto Stable Measurement Automatic Power Off (30mins) Low Battery Indicator IP67 Dust / Waterproof Replaceable Sensor Servicing Servicing Options Available ? Have you considered your servicing requirements? Much like a car, scientific instruments may need a bit of care to keep them working reliably and at their most accurate. ? The Allschoolabs Service Department have over 60 years experience in scientific instrumentation. We have a number of highly qualified internal and field-based service engineers able to perform a variety of jobs including preventative maintenance servicing and calibration. Allschoolabs can offer yearly service contracts which include two main types of preventative maintenance/calibration services ? the back to base service and an engineer visit to your site. These options are can be offered with differing turn around times depending on the instrument type and your requirements along with loan instruments if available. ? A typical preventative maintenance service includes the following: Inspection and testing of the unit Dismantling, cleaning and inspection of the key parts Correction of minor defects including adjustments if necessary Reassembly and testing Take post adjustment / cleaning readings Supply of calibration certificate Return of the item to you (back to base services) ? Request a quote for your servicing requirements today. Quote Request LAQUAtwin Measurements LAQUATWIN Three Step Measurement Follow simple, good testing procedures for accurate and dependable results: Calibrate correctly Avoid mixing samples and standards Always keep the sensor clean 1 Calibrate Always ensure the sensor is clean before calibrating. If not, clean thoroughly with water (don?t worry, LAQUAtwin meters are completely waterproof!). Place some standard solution on the sensor and press the calibration button. Once the smiley face appears, indicating that calibration is complete, wash off the standard solution with water and dry with a clean, soft tissue. 2 Test LAQUAtwin meters only need a tiny amount of sample - so no beaker is necessary. Fill the sensor with the sample and when the smiley face appears, the measurement is complete. 3 Clean Clean the sensor thoroughly with water, ready for the next test. When the sensor is nearing the end of its usable lifetime, it can be replaced; You don?t need to replace the meter. Sensors will need to be replaced after approx. 1500 measurements or when calibration cannot be completed. Sensors are sold separately and are easily removed and replaced. ? LAQUATwin One meter Six Different Methods Choose the best method according to your sample, your situation and your needs. Immersion: When you?re in the lab, you can test the sample in a beaker. Ensure the sensor guard sliding cap is open. Scoop: Use as a scoop to test water, for example from a river. Drops: LAQUAtwin meters can measure sample volumes as low as 0.05 mL. Place a drop of the sample onto the sensor with a pipette. Using the HORIBA sampling sheet, volumes down to 0.05 mL can be tested (except for conductivity measurements). Solid samples: Foods containing some moisture can be tested by placing a small piece directly onto the sensor. Powders: LAQUAtwin meters can also test dry powders. Simply place the powder sample onto the sensor, and drop on your defined volume of pure water. Paper and textiles: To test sheets of paper and textiles, cut up the sample into small pieces and place directly onto the sensor. Drop on your defined volume of pure water. LAQUAtwin sampling sheet. The sampling sheet allows trace volumes to be analysed. For example, you can even measure the pH of human skin by wiping with a sampling sheet soaked in pure water, and placing it on the sensor. Using the HORIBA sampling sheet, volumes down to 0.05 mL can be tested (except for conductivity measurements). Horiba Electrode Selection General Laboratory and Field Samples Plastic-body?pH electrodes, either refillable or gel-filled,?are ideal for field measurement.? The glass membrane of refillable electrodes offers an excellent response to low-conductivity water. When the refilling port is covered with the movable slider, the electrode can be used in submerged measurements for up to 30 minutes in a 1m depth of water.? Gel-filled pH electrode?does?not require?refilling. ToupH electrodes are?more impact-resistant than conventional glass-body pH electrodes due to their thick glass membrane. These electrodes are recommended for general laboratory samples. Examples below: 9651-10D (for field-testing) 9625-10D (for general-purpose use) 9615S-10D Standard ToupH electrode (for general laboratory application) 9415-10C Standard ToupH electrode (for general laboratory application) Precise Measurement High stability is required for precise measurement. The following electrodes have glass membranes highly sensitive to low-conductivity water and non-aqueous solvents. A movable sleeve is used at the liquid junction for easy cleaning and clog-free measurement. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 6367-10D (for high accuracy pH measurement) Smaller Volume Samples The volume of the sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. ToupH electrodes are constructed with a thick glass membrane that is highly resistant to impact and chemicals. Long pH electrodes, which come in 3 mm and 8 mm diameters, are suitable for test tubes and tall containers, while micro pH electrodes with 3 mm diameter are perfect for small tubes and trace amounts of samples.? Examples below: 9618S-10D Micro ToupH electrode (for low-volume samples) 9418-10C Micro ToupH electrode (for low-volume samples) 9680S-10D Long ToupH electrode (for large containers and long tubes) 9480-10C Long ToupH electrode (for large containers and long test tubes) 6069-10C (for very slender test tubes) Low Conductivity Samples pH measurement of low conductivity samples such as pure water and non-aqueous solvents can be very challenging. The glass membranes of the following pH electrodes produce an excellent response in the above-mentioned samples. 9481-10C Sleeve ToupH electrode (for viscous and non-aqueous samples) 9681S-10D Sleeve ToupH electrode (for viscous and non-aqueous samples) 9630-10D (for low conductivity samples) Solid and Semi-solid Samples Needle-type pH electrodes can be used to pierce and penetrate solid samples, such as meat, fruits, and food samples, during measurement. Flat pH electrodes and ISFET electrodes are ideal for surface pH measurement of moisture-containing solids such as nutrient agar, skin, cloth, leather, paper, meat, and leaves.? ISFET electrodes can also be used in food processing and other applications where glass is prohibited. 6252-10D (for food samples) 6261-10C (for flat surface measurement) Request Information... For more information on this product please click the Request information button below and we will get back to you as soon as we can. Request information Alternatively, a consultation visit from one of our highly experienced product specialists is available for this range. Typically our specialist will be able to go through the following aspects with you to help you make the right choices and be able to deliver them on time and and on budget. Your product or service requirements Performance criteria Budget constraints Site access Project timeframes Services available Environmental factors Please click the Request Consultation button below and we will get back to you as soon as we can. Request Information The links above will take you to our request information page which will forward your enquiry to our team. Please provide as much detail as possible so that we can get back to you with the right information. We normally aim to get back to you same day or within 24 hours on weekdays. If you enquiry is more urgent please call our support team on 01954 233 120 Feefo Reviews Related Blogs Question: How can I measure the salinity of Brine? Answer: a Brinometer! Brine is simply defined as a solution of salt in water. It has a wide variety of uses from the transport of thermal energy, de-icing the roads or in cooking to preserve meat or vegetables. The low levels of salinity commonly?found in?food or seawater can be tested in a number of ways such as on the Laqua Twin sodium meter?,?Laqua Twin salt meter?or for a multi-pa...8 years ago Product Attachments Horiba LAQUAtwin Pocket Water Quality Meters (3.14 MB) HORIBA LAQUA Product Brochure (15.04 MB) LAQUAtwin Ion Sensor Maintenance Procedures (1.39 MB) LAQUAtwin pH Sensor Maintenance Procedures (1.44 MB) Soil Nitrate Measurement for Determination of Plant-AvailableNitrogen (1.98 MB) LAQUAtwin Conductivity Sensor Maintenance Procedures (1.34 MB) Soil Salinity Measurement in Almond Orchard (5.01 MB) Nitrate Measurement in Turf Grass (2.37 MB) Rapid In-Field Determination of Nitrogen in Onions (1.74 MB) LAQUAtwin Technical Tips (3.35 MB) Horiba LAQUAtwin Application Note - Rapid Screening for Hypocalcemia in Cow's Blood on Dairy Farm (2.38 MB) LAQUA Range Brochure (24.74 MB) More Information More Information ColourWhiteSku: 1723836528-481
LAQUAtwin Calcium Ion Meter for animal blood Ca-11C
₦363,670.00Original price was: ₦363,670.00.₦303,060.00Current price is: ₦303,060.00.₦363,670.00Original price was: ₦363,670.00.₦303,060.00Current price is: ₦303,060.00. Add to basket Quick View