Brand: Drager?
Model: OXYLOG 3000 PLUS
Drager Oxylog 3000 Plus Offer high ventilation performance with features such as AutoFlow integrated capnography and non-invasive Ventilation, the compact and robust Oxylog 3000 plus helps you transport your patients safely and provides feedback on the correctness of intubation and ventilation effectiveness. The Oxylog 3000 plus gives you the confidence to master even the most demanding situations.
Specification of?Drager Oxylog 3000 Plus:
BrandDragerModel Name/NumberOxylog 3000 PlusPatient Age GroupAdultTidal Volume0.05 to 2.0 L, BTPSVentilation ModesVC-CMV, VC-AC, VC-SIMV, SpnCPAP, PC-BIPAPRespiratory Rate2 to 60/min (VC-SIMV, PC-BIPAP), 5 to 60/min (VC-CMV, VC-AC), 12 to 60/min for apnoea ventilation
Oxygen concentration40 to 100 Vol.>#/td###Inspiratory PressurePEEP +3 to +55 mbarPEEP/CPAP0 to 20 mbarInspiratory time0.2 to 10 secondsInspiratory flow100 L/min @ supply pressures > 350 kPa / 51 PSI; 80 L/min @ supply pressures < 350 kPa / 51 PSI; 39 L/min @ supply pressures <270 kPa / 39 PSIPeak Pressure0 to 35 mbar (relative to PEEP), slope adjustable in slow, standard, fastLeakageVTe. is approx. 60% lower than VTi (not applicable in NIV)Incorrect patient hoseThe ventilator detects if an incorrect patient hose type is connectedTemperature (device) During Operation-20 to +50?C for the basic device, +10 to +40 ?C for CO? sensorAtmospheric pressure During Operation570 to 1200 hPaRelative humidity During Operation5 to 95 % (no condensation)Electromagnetic compatibilityIn accordance with IEC/EN 60601-1-2:2007, EN 794-3 and ISO 10651-3AirworthinessIn accordance with RTCA DO-160F, sections 7, 8, 16.6, 18.3.1, 17, 19.31, 20, 21, 25Mechanical strengthIn accordance with MIL-STD 810F, method 514.5Display unit sizePixels: 240 x 128, Visible area: 108 x 56 mmDisplay TechnologyElectro-luminescence (EL)Curve displayAirway pressure Paw curve, flow curve, CO? curve (optional)Current consumption24 V ?6 VDCDimensions290 x 184 x 175 mmWeightApproximately 5.8 kg (including internal battery)OptionsIntegrated mainstream CO? measurement, Real-time data export via RS232, MEDIBUS protocol, AutoFlow: volume targeted - pressure-controlled ventilationVentilation time ratio1:100 to 50:1Trigger sensitivity1 to 15 L/minMeasured value displayMVe, FiO?, RR, VTe, PEEP, Pmean, PIP, Pplat, MVesp, RRspon, etCO?CPR-behaviorPressure-limited, non-constant-volume ventilation during inspiration time when Pmax is reachedPatient hose typesReusable adult hose (1,5 m / 3 m), Disposable adult hose (1,5 m / 3 m), Disposable pediatric hose (1,9 m)Input voltage24 V ?6 VDCAC/DC power packInput: 100 to 240 V~ / 50 to 60 Hz / 0.9 to 0.4 A~DC/DC converterInput: 12 / 24 / 28 VDC; 5 A / 2.5 A / 2.1 AOperating timeApproximately 9.5 hoursOperation timeApproximately 7.5 hoursBattery TypeLithium-ion batteryCharging timeApproximately 4 hoursFeatures of Drager Oxylog 3000 Plus:
High-performance ventilation capabilityWide range of ventilation modes and autoflowAdvanced data export functionalityPerfectly portable & proven durability
Reviews