YES! We deliver orders to 2184 cities worldwide →
See your region

Philips Efficia CM10 Multipara Patient monitor - 5 Parameters

Sku: 1713898208-104

Estimated Delivery Date: International: 2-3 days (by DHL Express)

See Recent Deliveries to your City Here

Philips Efficia CM10 Multipara Patient monitor - 5 Parameters

Sku: 1713898208-104

100.00

Quantity:

Available in stock

Express delivery on this item

380000+ Products Online

100% Money Back

Description

Philips Efficia is the best option when you are looking for a budget-friendly and high-quality patient monitor. Philips Efficia cm10 keep your budget under control because Philips Efficia cm10 price is the best price if you compare this monitor qualities to any other monitor: Having a choice of metrics to select from allows you to respond to changing patient situations. The physiological parameters created by Philips are used in Efficia patient monitors. You can expect the same high-quality experience from Efficia cm10 you’ve come to expect from Philips patient monitors. The primary monitoring feature of Philips cm10 monitor is based on proven precise and reliable Philips physiological measures.

The Efficia CM10 patient monitor displays ECG, basic arrhythmia, ST analysis, SpO2 noninvasive blood pressure (Philips FAST SpO2, Masimo rainbow SET*, or Nellcor OxiMax), dual temperature, and impedance respiration. Depending on your selections, the monitors can also help you measure:
? Dual invasive blood pressure
? Sidestream CO2 (Respironics LoFlo, Respironics CapnoTrak
and Microstream) or Mainstream (Respironics Capnostat)
? Enhanced arrhythmia analysis
Philips Efficia CM10 Patient monitor Specifications:
Time-tested physiological measurements relied on for over 200 million patients every year
Reliable Philips Efficia consumables, available in cost-effective bundles or through a delivery service that helps simplify your ordering logistics
Solidly built and reliable, able to handle heavy workloads, physical knocks and electrostatic interference
Ready for plug-and-play connectivity to Philips Efficia central monitoring
Built-in HL7 connectivity to interface with hospital Information systemsPhilips Efficia CM10 Features and benefits
? 10?inch color screen with large numerics and waveforms (touchscreen optional)
? Easy selection of different display layouts
? Retrospective clinical information review from up to 240 hours of tabular and graphical trends and optional 48 hours full disclosure
? Lithium?ion battery, with practical access slots ? making it simple to change the battery (with a standard, flat-head screwdriver)
? Audible and visual alarm indicators
? Compatible with a wide range of Philips supplies and accessories
? Connectivity to Efficia rack and modules
? Connectivity to central station
? Interface to other systems using HL7 data over the serial connection, or LAN/optional WLAN
? Password?protected administrator and maintenance
? Easy software upgrades over the USB port
? Automatic or prompted patient ID entry using the optional barcode scanner support
? Optional integrated recorder for easy printing of patient data
? Optional roll stand, or wall mounts
Other Specification of Philips Efficia Cardiac Monitor:
BrandPhilipsSeriesEfficiaModelCM10Width27 cm (10.6 in)Height22 cm (6.6 in)Depth17 cm (6.7 in)Weight (with no battery)< 3.3 kg (7.0 lb)DisplayType: 25.6 cm (10.1 in) LCDResolution1280 active pixels/line, 800 active lines/frameViewing angle? 15BatteryWeight, 3?cell, lithium?ion: 0.25 kg (0.55 lb), 9?cell, lithium?ion: 0.5 kg (1.1 lb)Channels4Recorder typethermalPaper width58 mmUser selectable speeds6.25, 12.5, 25 and 50 mm/sAlarmsThree alarm severity levels (high, medium, low) with corresponding visual and audio indicatorsECGHeart rate rangeAdult: 15 ? 300 bpm, Pediatric and neonatal: 15 ? 350 bpmHeart rate accuracy? 1% or ? 1 bpmLeads3?lead and 5?leadPacemaker detectionIndicator of pace pulse on the waveform display?Invasive blood pressureMeasurement range-40 to 360 mmHgInput sensitivity5 ?V/V/mmHgAccuracy? 1%Drift:less than 0.05%/? CWarm-up time< 15 secondsNoninvasive blood pressure (NBP)MethodOscillometricAdult measurement rangeSystolic: 30 ? 270 mmHg (4.0 ? 36.0 kPa), Diastolic: 10 ? 245 mmHg (1.3 ? 32.7 kPa), MAP: 20 ? 255 mmHg (2.7 ? 34.0 kPa)Pediatric measurement rangeSystolic: 30 ? 180 mmHg (4.0 ? 24.0 kPa), Diastolic: 10 ? 150 mmHg (1.3 ? 20.0 kPa), MAP: 20 ? 160 mmHg (2.7 ? 21.3 kPa)Neonatal measurement rangeSystolic: 30 ? 130 mmHg (4.0 ? 17.3 kPa), Diastolic: 10 ? 100 mmHg (1.3 ? 13.3 kPa), MAP: 20 ? 120 mmHg (2.7 ? 16.0 kPaBlood pressure accuracyMaximum standard deviation: ? 8 mmHg, Maximum mean error: ? 5 mmHgPulse rate range40 ? 300 bpmPulse rate accuracy40 ? 100 bpm: ? 5 bpm, 101 ? 200 bpm: ? 5% of reading, 201 ? 300 bpm: ? 10% of readingInitial cuff inflationAdult: 160 mmHg (21.3 kPa), Pediatric: 140 mmHg (18.7 kPa), Neonatal: 100 mmHg (13.3 kPa)NBP intervalsAutomatic measurements at intervals of 1, 2, 3, 5, 10, 15, 30, 60, 90, 120 minutes and STATTemperature measurementsMeasurement range for all measurement sites0? to 50? C (32? to 122? F)Accuracy? 0.1? C ? without a temperature probeMode of operation?Direct modeHeating and cooling transient response time? 150 sMicrostream CO2Measurement range0 ? 150 mmHgData sample rate:Waveform sampling, 20 samples per secondFlow rate?50 ml/min, + 15 ml/min, ?7.5 ml/minCO2 waveform resolution0.1 mmHgetCO2, imCO2 resolution1.0 mmHgInitialization and power-up time40 seconds (typical), 3 minutes maximumTotal response time for adults/paediatrics3.9 seconds, for 10% ? 90% changes in CO2 concentrationMaximum CO2 response time5.3 seconds (typical)Calibration intervalInitial calibration after one year or 1,200 hoursLeak tightness< 250 mBar/minAccuracy (for respiratory rates up to 80 rpm)? 2 mmHg in the range 0 mmHg ? 38 mmHg, ? 5% of reading + 0.08% for every 1 mmHg above 38 mmHg in the range 39 mmHg ? 150 mmHgRespiration rate range0 ? 150 rpm?Respiration accuracy? 1 rpm in the range 0 ? 70 rpm, ? 2 rpm in the range 71 ? 120 rpm, ? 3 rpm in the range 121 ? 150 rpmEffects of cyclical pressureOverpressure: + 100 cmH2O, Underpressure: ?20 cmH2OMainstream CO2*Measurement range0 ? 150 mmHg**ImCO2 measurement range3 ? 50 mmHgData sample rateWaveform sampling, 20 samples per secondCO2 waveform resolution0.1 mmHgetCO2, imCO2 resolution1.0 mmHgInitialization timeFull specification etCO2 measurement displays after warm-up, in less than 2 minutesTotal response time< 2 secondsCalibration intervalNo calibration requiredAuto zero intervalOnly required when changing the airway adapter styleAccuracy (gas temperature at 35? C)? 2 mmHg in the range 0 ? 40 mmHg, ? 5% of reading in the range 41 - 70 mmHg, ? 8% of reading in the range of 71 ? 100 mmHg, ? 10% of reading in the range of 101 ? 150 mmHgRespiration rate range0 ? 150 rpmRespiration rate accuracy? 1 rpmDrift of measurement accuracyShort-term drift (4 hours of use): does not exceed 0.8 mmHg, Long-term drift (120-hour period): retains accuracy specificationBarometric pressureConfigured by system administratorImpedance respirationMethodTransthoracic impedanceMeasurement range3 ? 150 rpmResolution1 rpmAccuracy? 1 rpm in the range 3 ? 120 rpm, ? 2 rpm in the range 121 ? 150 rpmRespiration excitation waveform< 250 ?A, 37 kHz nominalECG leads usedRA to LLDisplay sweep speeds6.25, 12.5, 25, 50 mm/sLeadoff conditionDetected and displayedECG arrhythmiaRespiration excitation waveform< 250 ?A, 37 kHz nominal?Time to alarm for tachycardia< 5.0 secondsTall T-wave rejection capabilityTested to a T-wave amplitude of 1.8 mVHeart rate meter accuracy and response to irregular rhythm Ventricular bigeminy: 80 bpm, Slow alternating ventricular bigeminy: 60 bpm, Rapid alternating ventricular bigeminy: 120 bpm, Bidirectional systoles: 90 bpm Time to alarm for cardiac standstill?< 10 secondsTime to alarm for low heart rate< 10 secondsTime to alarm for high heart rate< 10 secondsPacemaker pulse rejectionRejects ? 2?? 700 mV; pulse widths 0.1 ? 2.0 ms; with no overshoot?List of Supplies with Cardiac Multipara Monitor: Name of accessoriesQuantityECG Cable1Spo2 Sensor1NIBP Cuff (Adult) with Tube1Temperature Sensor1Power Cable1User Manual1

Reviews
Ratings

0.0

0 Product Ratings
5
0
4
0
3
0
2
0
1
0

Review this product

Share your thoughts with other customers

Write a review

Reviews

There are no reviews yet.

Philips Efficia CM10 Multipara Patient monitor – 5 Parameters 100.00
Home Shop Cart Account
Shopping Cart (0)

No products in the cart. No products in the cart.