Brand: Philips Respironics
Model: Trilogy 202
The Philips Respironics Trilogy 202 is both a volume-control & pressure-control ventilator for invasive and noninvasive ventilation. Versatile breath delivery and setup options provide greater continuity of care.
Features of?Philips Respironics Trilogy 202 :
Leak compensationPortable design for intra-hospital transportAuto-Trak improves synchronyUniform settings to support the hospital to home transitionLeak compensated volume modes to improve consistencySpecifications of Philips Respironics Trilogy 202:
Alarms:
Circuit disconnectOff, 10 – 60 s
Low tidal volumeOff, 50 – 2000 ml
ApneaOff, 10 – 60 s and 4 – 60 BPM
High tidal volumeOff, 50 – 2000 ml
High minute ventilationOff, 1 – 99 l/min Off, 1 – 99 l/min
Low minute ventilationOff, 1 – 99 l/min
High respiratory rateOff, 4 – 80 BPM
Low respiratory rateOff, 4 – 80 BPM
Monitored parameters:
Tidal volume0 – 2000 ml
Minute ventilation0 – 99 l/min
Estimated leak rate0 – 200 l/min
Respiratory rate0 – 80 BPM 0 – 80 BPM
Peak inspiratory flow0 – 200 l/min
Peak inspiratory pressure0 – 99 cm H?O
Mean airway pressure0 – 99 cm H?O
>td ###0 – 100 %
I:E ratio9.9:1 – 1:9.9
Controls:
CPAP4 – 20 cmH20 (passive leak port circuits)
IPAP50 cm H?O
EPAP/PEEP (a)0 – 25 cmH20 (active valve circuits)
EPAP/PEEP (b)4 – 25 cmH20 (passive leak port circuits)
Pressure support0 ? 30 cmH2O
Tidal volume50 – 2000 ml
Breath rate(a)0 – 60 BPM (AC mode) BPM
Breath rate(b)1 – 60 BPM (all other modes) BPM
Inspiratory time0.3 – 5.0 s Synchrony features
Rise time1 – 6 (relative scale)
Ramp start pressure (a)0 – 25 cmH20 (active circuits)
Ramp start pressure (b)4 – 25 cmH20 (passive circuits)
Ramp start pressure (c)4 – 19 cmH20 (CPAP mode)
Ramp timeOff, 5 – 45 minute(s)
C-FlexOff, 1 – 3 (relative scale)
Flow trigger sensitivity1 – 9 l/min
Flow cycle sensitivity10 – 90 %
Oxygen:
FiO221 – 100 %
02 flush2 min at 100%
02 input pressure range276 – 600 kPa (40 – 87 psi)
Circuit types:
Active exhalation valve with proximal airway pressure (PAP)Yes
Active exhalation valve with flow sensorYes
Passive exhalation portYes
Environmental:
Operating temperature5 ? 40 ?C
Relative humidity15 – 95 %
Storage temperature-20 ? 60 ?C
Atmospheric pressure60 – 110 kPa (450 – 825 mmHg)
Electrical:
Input voltage100 – 240 VAC and 50/60 Hz and 2.1 A
Detachable battery voltage14.4 VDC
Internal battery life3 hours under normal conditions
Detachable battery life3 hours under normal conditions
external battery connection12 VDC
Volume modes:
MPV Mouthpiece Ventilation ModeYes
Pressure control (PC)Yes
Synchronized intermittent mandatory ventilation (SIMV)Yes
SIMV with pressure support (SIMV w/PS)Yes
Control ventilation (CV)Yes
Compliance:
IEC 60601-1 Medical electrical equipment Part 1: General requirements for safetyYes
IEC 60601-1-2 General requirements for safety ? collateral standard Electromagnetic compatibility ? requirements and testsYes
IEC 60601-2-12 Medical electrical equipment Part 2-12: Particular requirements for the safety of lung ventilators ? Critical Care ventilatorsYes
Pressure modes:
Pressure control (PC)Yes
Pressure control-SIMV (PC-SIMV)Yes
Spontaneous ventilation (S)Yes
Spontaneous ventilation with timed back-up (S/T)Yes
Timed ventilation (T)Yes
Continuous positive airway pressure (CPAP)Yes
Average volume assured pressure support (AVAPS)With passive circuit type, S, S/T, PC, and T modes only
Patient types:
AdultYes
Pediatric? 5 kg or greater
Synchrony features:
Auto-Trak sensitivityAuto-Trak sensitivity Auto-adaptive triggering, cycling, and leak compensation (available in all modes, passive circuit only)
Adjustable flow triggering1 ? 9 l/min (available in all modes and circuit types)
Options:
Detachable back-up batteryOffering up to 3 hours additional operating time
Hospital roll standProvides convenient accessory basket and humidifier mount
DirectView1 GB SD card data storage integrated into the ventilator software